The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Radial augmentation index: A useful and easily obtainable parameter for vascular aging
Open accessAbstract
BACKGROUND: It has been shown that the systolic augmentation index (AI) in the central arteries, including the aorta and carotid arteries, changes with age. The AI can also be obtained from the peripheral arteries. The possible usefulness of AI obtained from the radial artery as an index for vascular aging was investigated. METHODS: Radial arterial waveforms were obtained from 632 subjects with no cardiovascular disease, using radial tonometry. Radial AI was calculated as follows: (Second peak systolic blood pressure [SBP2] - diastolic blood pressure [DBP]) / (first peak SBP - DBP) x100 (%). RESULTS: Radial AI was significantly higher in women than in men (81.1% +/- 16.1% compared with 69.5% +/- 16.3%, P < .001). Radial AI was positively related to age in healthy men and women (r = 0.619, P < .001, and r = 0.644, P < .001, respectively). When comparing subjects in their 20s to those in their 70s, radial AI increased 1.56 times (from 53.2% to 83.0%) in men and 1.49 times (from 64.6% to 96.4%) in women. Multiple regression analysis showed that age is a potent predictor of radial AI in addition to gender, DBP and pulse rate. CONCLUSIONS: These findings indicate that simple and easily-obtainable radial AI is age-dependent and could be a useful index of vascular aging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Mitchell, G. F., Parise, H., Benjamin, E. J., Larson, M. G., Keyes, M. J., Vita, J. A., Vasan, R. S., & Levy, D. (2004) · Hypertension · doi:10.1161/01.hyp.0000128420.01881.aa · Cited by 1,501
Arterial stiffness, wave reflections, and the risk of coronary artery disease
Weber, T., Auer, J., O’Rourke, M. F., Kvas, E., Lassnig, E., Berent, R., & Eber, B. (2004) · Circulation · doi:10.1161/01.cir.0000105767.94169.e3 · Cited by 1,081
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms
NICHOLS, W. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.10.009 · Cited by 1,001
Arterial wave reflections and survival in end-stage renal failure
London, G. M., Blacher, J., Pannier, B., Guérin, A. P., Marchais, S. J., & Safar, M. E. (2001) · Hypertension · doi:10.1161/01.hyp.38.3.434 · Cited by 853
McDonaldʼs Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, ed. 3
Nichols, W. W., OʼRourke, M. F., & Kenney, W. L. (1991) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-199111000-00023 · Cited by 451
Schram, M. T., Henry, R. M. A., van Dijk, R. A. J. M., Kostense, P. J., Dekker, J. M., Nijpels, G., Heine, R. J., Bouter, L. M., Westerhof, N., & Stehouwer, C. D. A. (2004) · Hypertension · doi:10.1161/01.hyp.0000111829.46090.92 · Cited by 428
C-Reactive Protein Is Associated With Arterial Stiffness in Apparently Healthy Individuals
Yasmin, McEniery, C. M., Wallace, S., Mackenzie, I. S., Cockcroft, J. R., & Wilkinson, I. B. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.zhq0504.0173 · Cited by 400
Gender-Related Differences in the Central Arterial Pressure Waveform
Hayward, C. S., & Kelly, R. P. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00378-1 · Cited by 323
Practice guidelines for primary care physicians: 2003 ESH/ESC hypertension guidelines.
Cífková, R., Erdine, S. E., Fagard, R. H., Farsang, C., Heagerty, A. M., Kiowski, W., Kjeldsen, S., Lüscher, T. F., Mallion, J. M., Mancia, G., et al. (2003) · PubMed · doi:10.1097/01.hjh.0000084773.37215.1b · Cited by 299
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Bae, G. Y., Pak, S. W., Kim, D., Lee, G., Kim, D. H., Chung, Y., & Cho, K. (2016) · Advanced Materials · doi:10.1002/adma.201600408 · Cited by 646
Supercapacitive Iontronic Nanofabric Sensing
Li, R., Si, Y., Zhu, Z., Guo, Y., Zhang, Y., Pan, N., Sun, G., & Pan, T. (2017) · Advanced Materials · doi:10.1002/adma.201700253 · Cited by 296
He, J., Xiao, P., Lu, W., Shi, J., Zhang, L., Liang, Y., Pan, C., Kuo, S.-W., & Chen, T. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.02.036 · Cited by 291
Lu, P., Wang, L., Zhu, P., Huang, J., Wang, Y., Bai, N., Wang, Y., Li, G., Yang, J., Xie, K., et al. (2021) · Science Bulletin · doi:10.1016/j.scib.2021.02.019 · Cited by 268
G. Celler, B., Butlin, M., Argha, A., Tan, I., Yong, A., & Avolio, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3079578 · Cited by 24
Effects of a Dietary Beetroot Juice Treatment on Systemic and Cerebral Haemodynamics—A Pilot Study
Millis, R. M. (2016) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2016/20049.8113 · Cited by 10
The Role of Wearable Technologies and Telemonitoring in Managing Vascular Disease
Chan, C., Sounderajah, V., Acharya, A., Normahani, P., Bicknell, C., & Riga, C. (2020) · Vascular and Endovascular Review · doi:10.15420/ver.2019.11 · Cited by 6
Metadata
- Authors
- KOHARA, K., TABARA, Y., OSHIUMI, A., MIYAWAKI, Y., KOBAYASHI, T., & MIKI, T.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-01
- Volume
- 18
- Issue
- 1 Pt 2
- Pages
- 11-14
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2199162961
- Cited by
- 255
- References
- 18
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.