Self-Monitoring of Blood Pressure Promotes Achievement of Blood Pressure Target in Primary Health Care
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The majority of hypertensive patients do not reach the target blood pressure (BP). We sought to clarify whether intermittent self-monitoring of BP leads to better BP control compared to ordinary treatment in general practice. Two hundred sixty-nine hypertensive patients participated in this multicenter, randomized, parallel-group study in primary health care. Home BP was measured in the self-monitoring (SM) group at 0, 2, 4, and 6 months, and in the control (C) group at 0 and 6 months. The participating physicians were instructed to intensify the antihypertensive therapy when needed. At the beginning, both groups had similar home BP levels (SM 143.1 ± 17.4/85.3 ± 7.4 mm Hg v C 143.9 ± 18.3/85.4 ± 7.5 mm Hg). After 6 months, there were significant decreases in systolic (P ≤ .0001), diastolic (P ≤ .0029), and pulse pressures (P ≤ .021) in both groups. Systolic (−7.8 ± 13.1 mm Hg v −4.5 ± 12.2 mm Hg, P = .047) and pulse pressure (−4.7 ± 9.0 mm Hg v −2.2 ± 10.0 mm Hg, P = .042) decreased significantly more than in the self-monitoring group. The decrease in diastolic pressure was similar in both groups (SM −3.1 ± 6.2 mm Hg v C −2.3 ± 8.3 mm Hg, P = not significant). The patients in the SM group reached home BP target more often than those in the C group (29% v 16%, P = .016). There was a nonsignificant trend toward lower office BP values in the SM group. Self-monitoring decreased systolic and pulse pressure significantly more than ordinary treatment and promoted achievement of target BP. This was most likely due to improved patient compliance and more active treatment by the physicians. Our results suggest that home measurement is useful in the control of hypertension. Am J Hypertens 2005;18:1415–1420 © 2005 American Journal of Hypertension, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Cited by
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Interventions used to improve control of blood pressure in patients with hypertension
Glynn, L. G., Murphy, A. W., Smith, S. M., Schroeder, K., & Fahey, T. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005182.pub4 · Cited by 668
Tucker, K. L., Sheppard, J. P., Stevens, R., Bosworth, H. B., Bove, A., Bray, E. P., Earle, K., George, J., Godwin, M., Green, B. B., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002389 · Cited by 658
Self-citationRiegel, B., Moser, D. K., Buck, H. G., Dickson, V. V., Dunbar, S. B., Lee, C. S., Lennie, T. A., Lindenfeld, J., Mitchell, J. E., Treat‐Jacobson, D. J., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006997 · Cited by 620
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Uhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-3-201308060-00008 · Cited by 368
Bray, E. P., Holder, R., Mant, J., & McManus, R. J. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.489567 · Cited by 245
Sheppard, J. P., Tucker, K. L., Davison, W. J., Stevens, R., Aekplakorn, W., Bosworth, H. B., Bove, A., Earle, K., Godwin, M., Green, B. B., et al. (2020) · American Journal of Hypertension · doi:10.1093/ajh/hpz182 · Cited by 108
Self-citationLogan, A. G., Dunai, A., McIsaac, W. J., Irvine, M. J., & Tisler, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f2fdd4 · Cited by 106
Kerry, S. M., Markus, H. S., Khong, T. K., Cloud, G. C., Tulloch, J., Coster, D., Ibison, J., & Oakeshott, P. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.120832 · Cited by 74
NIIRANEN, T., KANTOLA, I., VESALAINEN, R., JOHANSSON, J., & RUUSKA, M. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.10.017 · Cited by 42
Self-citationStimulant Dosing for Children With ADHD: A Medical Claims Analysis
Olfson, M., Marcus, S., & Wan, G. (2009) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/chi.0b013e31818b1c8f · Cited by 39
Satoh, M., Tatsumi, Y., Nakayama, S., Shinohara, Y., Kawazoe, M., Nozato, Y., Kunimura, A., Murakami, T., Toyama, M., Muroya, T., et al. (2025) · Hypertension Research · doi:10.1038/s41440-024-01981-4 · Cited by 25
Cuffee, Y. L., Sciamanna, C., Gerin, W., Lehman, E., Cover, L., Johnson, A. A., Pool, A., & Yang, C. (2019) · American Journal of Hypertension · doi:10.1093/ajh/hpy160 · Cited by 11
Grover, S., Mishra, H. P., Gupta, R., & Gupta, L. K. (2025) · Journal of Hypertension · doi:10.1097/hjh.0000000000004008 · Cited by 8
Metadata
- Authors
- HALME, L., VESALAINEN, R., KAAJA, M., & KANTOLA, I.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-11
- Volume
- 18
- Issue
- 11
- Pages
- 1415-1420
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W1996996490
- Cited by
- 104
- References
- 2
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.