Home Blood Pressure Is as Reliable as Ambulatory Blood Pressure in Predicting Target-Organ Damage in Hypertension
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Our objective was to assess the value of home blood pressure (BP) monitoring in comparison to office BP measurements and ambulatory monitoring in predicting hypertension-induced target-organ damage. METHODS: Sixty-eight untreated patients with hypertension with at least two routine prestudy office visits were included (mean age, 48.6 +/- 9.1 [SD] years; 50 men). Office BP was measured in two study visits, home BP was measured for 6 workdays, and ambulatory BP was monitored for 24 h. All BP measurements were obtained using validated electronic devices. Target-organ damage was assessed by measuring the echocardiographic left-ventricular mass index (LVMI), urinary albumin excretion rate (AER) in two overnight urine collections, and carotid-femoral pulse-wave velocity (PWV) (Complior device; Colson, Garges-les-Gonesse, Paris, France). RESULTS: The correlation coefficients of LVMI with office BP were 0.24/0.15 (systolic/diastolic), with home BP 0.35/0.21 (systolic, P < .01), and with 24-h ambulatory BP 0.23/0.19, awake 0.21/0.16, and asleep 0.28/0.26 (asleep, both P < .05). The correlation coefficients of AER with office BP were 0.24/0.31 (diastolic, P < .05), with home BP 0.28/0.26 (both P < .05), and with 24-h ambulatory BP 0.25/0.24, awake 0.24/0.25 (diastolic, P < .05), and asleep 0.26/0.18 (systolic, P < .05). There was a trend for negative correlations between PWV and diastolic BP measurements (not significant). In multiple-regression models assessing independent predictors of each of the three indices of target-organ damage, systolic home BP and age were the only independent predictors of increased LVMI that reached borderline statistical significance. CONCLUSIONS: These data suggest that home BP is as reliable as ambulatory monitoring in predicting hypertension-induced target-organ damage, and is superior to carefully taken office measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of ten-year risk of fatal cardiovascular disease in Europe: the SCORE project
Conroy, R. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00114-3 · Cited by 5,290
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationSega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Self-citationSTERGIOU, G., SALGAMI, E., TZAMOURANIS, D., & ROUSSIAS, L. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.01.003 · Cited by 157
Self-citationKlausen, K. P., Scharling, H., Jensen, G., & Jensen, J. S. (2005) · Hypertension · doi:10.1161/01.hyp.0000169153.78459.50 · Cited by 106 · cited 1×
“diagnostic threshold was proposed (eg, 5 g/min).(26,27)”
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationAgarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Niiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.149336 · Cited by 390
Bliziotis, I. A., Destounis, A., & Stergiou, G. S. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283531eaf · Cited by 261
“Pulse wave velocity Three studies including 720 individuals reported correlation coefficients between home BP measurements and PWV (Tables 2 and 4) [28,31,32].”
BackgroundResultInfluentialSelf-citationas members of the Japanese Society of Hypertension Committee for Guidelines for Self-monitoring of Blood Pressure at Home, Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., et al. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 203
Chiang, C.-E., Wang, T.-D., Ueng, K.-C., Lin, T.-H., Yeh, H.-I., Chen, C.-Y., Wu, Y.-J., Tsai, W.-C., Chao, T.-H., Chen, C.-H., et al. (2015) · Journal of the Chinese Medical Association · doi:10.1016/j.jcma.2014.11.005 · Cited by 199
Home Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Self-citationGaborieau, V., Delarche, N., & Gosse, P. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e32830c4368 · Cited by 169
Maximum Value of Home Blood Pressure: A Novel Indicator of Target Organ Damage in Hypertension
Matsui, Y., Ishikawa, J., Eguchi, K., Shibasaki, S., Shimada, K., & Kario, K. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.171645 · Cited by 127
(2022) · PubMed Central · doi:10.6515/acs.202205_38(3).20220321a · Cited by 117
Hara, A., Tanaka, K., Ohkubo, T., Kondo, T., Kikuya, M., Metoki, H., Hashimoto, T., Satoh, M., Inoue, R., Asayama, K., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.174938 · Cited by 79
Office blood pressure measurement types: Different methodology—Different clinical conclusions
Stergiou, G. S., Kyriakoulis, K. G., & Kollias, A. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13420 · Cited by 41
Self-citationSelf blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
Screening for orthostatic hypotension using home blood pressure measurements
Cremer, A., Rousseau, A.-L., Boulestreau, R., Kuntz, S., Tzourio, C., & Gosse, P. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001986 · Cited by 29
Metadata
- Authors
- STERGIOU, G., ARGYRAKI, K., MOYSSAKIS, I., MASTORANTONAKIS, S., ACHIMASTOS, A., KARAMANOS, V, & ROUSSIAS, L.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-06
- Volume
- 20
- Issue
- 6
- Pages
- 616-621
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2005153205
- Cited by
- 109
- References
- 8
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.