The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring
Open accessAbstract
BACKGROUND: Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration-cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. METHODS: A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar's tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. RESULTS: Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P < .001). CONCLUSIONS: Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Patch monitors and MCT are the most complete outpatient ECG recording and increase the likelihood for detecting AF, and can provide accurate representation of AF burden for the duration of recording (Barrett et al., 2014;Rosenberg et al., 2013;Rothman et al., 2007;Turakhia et al., 2013;Schreiber et al., 2014).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Barrett et al., 2014
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Ambulatory ECG monitoring can be considered to establish a diagnosis or make a symptom-rhythm correlation, with longer term monitoring resulting in higher yield [1,4] .( Table 2 )”
From Evaluating and managing bradycardia (2020) · cites this paper as [4]
In the citing paper
“Although most of these devices are only single lead, they can be as effective or even exceed the ability of conventional Holter monitoring to detect arrhythmias owing to their convenient usability over longer periods of time55,56.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [55]
In the citing paper
“Several patientoperated devices 136,137 and extended continuous ECG monitoring using skin patch recorders 138 have been validated for detection of paroxysmal AF. 139”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [138]
In the citing paper
“Our study examined a more recent time period than prior investigations of long-term continuous monitors [5, 9] and suggests that changes in the device technology and accumulated operator experience may have resulted in improved patient compliance.”
From Incidence and timing of potentially high-risk arrhythmias detected through long term continuous ambulatory electrocardiographic monitoring (2016) · cites this paper as [5]
In the citing paper
“In another study by Barrett PM et al24 it was shown that adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (P < .001), although the Holter monitor detected more events during the initial 24‐h monitoring period (P = .013).”
From Portable out-of-hospital electrocardiography: A review of current technologies (2018) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318282ab8f · Cited by 1,294
Robinson, R. (1993) · BMJ · doi:10.1136/bmj.307.6907.793 · Cited by 819
Kim, M. H., Johnston, S. S., Chu, B. C., Dalal, M. R., & Schulman, K. L. (2011) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.958165 · Cited by 798
Jabaudon, D., Sztajzel, J. M., Sievert, K., Landis, T., & Sztajzel, R. F. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Occult Atrial Fibrillation in Cryptogenic Stroke
Ritter, M., Kochhäuser, S., Duning, T., Reinke, F., Pott, C., Dechering, D. G., Eckardt, L., & Ringelstein, E. B. (2013) · Stroke · doi:10.1161/strokeaha.111.676189 · Cited by 180
Cited by
Sorted by citations
Items 401–496 of 496
Oleynikov, V. E., Averyanova, E. V., Oreshkina, A. A., Barmenkova, Y. A., & Kulyutsin, A. V. (2022) · Translational Medicine · doi:10.18705/2311-4495-2022-9-2-27-36 · Cited by 1
Dispositional Flow and Related Psychological Measures Associated with Heart Rate Diurnal Rhythm
Jamalipournokandeh, O., Hori, J., Asakawa, K., & Yana, K. (2023) · Advanced Biomedical Engineering · doi:10.14326/abe.12.9 · Cited by 1
Bhuiya, T., Roman, S., Aydin, T., Patel, B., Zeltser, R., & Makaryus, A. N. (2023) · World Journal of Cardiology · doi:10.4330/wjc.v15.i2.56 · Cited by 1
Khan, M. S., Dawson, A. Y., Rosenthal, G. L., & Snyder, C. S. (2023) · Pediatric Cardiology · doi:10.1007/s00246-023-03354-z · Cited by 1
IoT-based Heartbeats Monitoring System
Tamron, M. A. N. B. M., Attarbashi, Z. S., Abuzaraida, M. A., Atitallah, N., Iftikhar, S., Handayani, D. O. D., & Basri, A. B. (2023) · IEEE International Conference on Computing, Engineering and Design (ICCED) · doi:10.1109/icced60214.2023.10425281 · Cited by 1
Sladojević, S., Anderla, A., Gutai, A., Arsenović, M., Sladojević, M., Stevanov, B., Sremčev, N., & Pržulj, Đ. (2024) · Tehnički glasnik · doi:10.31803/tg-20230615143201 · Cited by 1
Hardware-software implementation of a local Wi-Fi network for the transmission of biomedical signals
Gerasimova, Y., Ivel, V., Moldakhmetov, S., & Petrov, P. (2024) · Eastern-European Journal of Enterprise Technologies · doi:10.15587/1729-4061.2024.309387 · Cited by 1
Yang, R., Yang, L., Zhang, Q., Wang, S., & Xu, J. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1469108 · Cited by 2
Nassra, I., & Capella, J. V. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-36370-2.00004-9 · Cited by 1
CURRENT METHODS OF OUTPATIENT ELECTROCARDIOGRAPHIC MONITORING. CLINICAL ASPECTS
Pervova, E. V. (2017) · The Clinician · doi:10.17650/1818-8338-2017-11-2-58-73 · Cited by 2
Krahn, A. D., Yee, R., Skanes, A. C., & Klein, G. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00066-3 · Cited by 1
2018 KHRS Guidelines for Catheter Ablation of Ventricular Arrhythmias – Part1
Roh, S., Kim, S., Kim, Y.-N., Kim, J.-Y., Kim, J., Kim, T., Nam, G., Park, K., Park, H., Pak, H., et al. (2018) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2018.006 · Cited by 1
Karunadas, C. P., & Mathew, C. (2019) · Journal of Evidence Based Medicine and Healthcare · doi:10.18410/jebmh/2019/530 · Cited by 1
Optimizing prognosis in atrial fibrillation: A call to action in Portugal
Ferreira, J., António, N., Cortez‐Dias, N., Gonçalves, L. R., Sargento‐Freitas, J., HAFE, P. V., & Gil, V. M. (2020) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2020.07.011 · Cited by 1
de la Guía-Galipienso, F., Sanchis‐Gomar, F., & Quesada-Dorador, A. (2021) · Annals of Translational Medicine · doi:10.21037/atm-20-3492 · Cited by 1
Wireless ECG device for heart rhythm monitoring during dental extractions-a pilot study
Lešin, A., Mikić, I. M., Bandić, R., Vodanović, K., Kekez, I. V., Bečić, T., Tomašić, I., Vukojević, K., & Govorko, D. K. (2021) · International Conference on Smart and Sustainable Technologies (SpliTech) · doi:10.23919/splitech52315.2021.9566379 · Cited by 1
Paroxysmal Tachycardia Diagnosed by ECG247 Smart Heart Sensor in a Previously Healthy Child
Jortveit, J., Früh, A., & Odland, H. H. (2022) · Case Reports in Pediatrics · doi:10.1155/2022/9027255 · Cited by 1
Vanchiere, C. A., McHugh, S., BEDENKO, E., Whitman, I. R., Gangireddy, C., Basil, A. K., Cooper, J., Edmundowicz, D., Brisco‐Bacik, M. A., & Cronin, E. M. (2022) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2022.130207 · Cited by 1
Xie, R., Hong, S., Gao, G., Zhong, J., Geng, L., Gao, S., Xu, Y., Meiling, D., Li, J., Li, Y., et al. (2021) · Research Square · doi:10.21203/rs.3.rs-1056296/v1 · Cited by 1
Pfeiffer, S., Meyer, S., Amft, O., Anzai, D., Wang, J., Fischer, G., & Kirchner, J. (2020) · doi:10.36227/techrxiv.13295711.v2 · Cited by 1
VLSI Technology for Real Time Monitoring System of High Risk Cardiac Patients
Kavya, G., & Bai, V. T. (2014) · Studies on Ethno-Medicine · doi:10.1080/09735070.2014.11917647
Harańczyk, M., Konieczyńska, M., & Płazak, W. (2017) · Current research. Cardiology · doi:10.4172/2368-0512.1000097
Pidanov, O. Y. (2017) · The Bulletin of Contemporary Clinical Medicine · doi:10.20969/vskm.2017.10(6).24-30
Physical activity and atrial fibrillation risk in the middle-aged and elderly
Puddu, P. E. (2018) · European Journal of Preventive Cardiology · doi:10.1177/2047487318788917
Evaluación de registros holter durante 19 horas en el contexto de la teoría de la probabilidad
Rodríguez, J. O., V, Prieto, S. E., Páez, J. A. P., Correa, C., Montenegro, C., Cortés, J. A., & Castro, M. (2019) · Revista chilena de cardiología · doi:10.4067/s0718-85602019000100020
Evaluating the Process of Ambulatory Electrocardiographic Monitor Application and Completion Rates
Bhatnagar, A. S. (2019) · KU ScholarWorks (University of Kansas)
Development and Application of Mobile Technology and the Internet of Things to Aid Primary Care
Wong, A. K. L. (2020) · Springer eBooks · doi:10.1007/978-981-15-2521-6_21
Value of a Novel 7-Day Patch Electrocardiography on Monitoring Cardiac Arrhythmias
Zhang, X., Zhao, Y., Yan, J., Chen, X., Xiong, Y., Zheng, P. P., Xing, J., Chen, D., Weng, J., Zhang, W., et al. (2020)
A Geometric Approach to Biomedical Time Series Analysis
Malik, J. (2020) · Cited by 1
Using a mobile cardiograph connected to cloud technologies for human condition monitoring
Fomovskyi, V. F., Artemenko, V. O., & Pylypenko, S. S. (2020) · SCIENCE, ENGINEERING AND TECHNOLOGY: GLOBAL TRENDS, PROBLEMS AND SOLUTIONS · doi:10.30525/978-9934-588-79-2-2.15
New frontiers in cardiac devices
Dennis, A. S., & Behar, J. M. (2020) · British Journal of Hospital Medicine · doi:10.12968/hmed.2020.0304
Development of electrodes with resistance to tension through structural shape control
Yang, S., Hong, S. K., & Lim, G. (2021) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2021.30.3.181
Desafios no diagnóstico da taquicardia por reentrada nodal: revisão bibliográfica
do Carmo, A. B., & Sobral, M. L. P. (2021) · Revista de Medicina · doi:10.11606/issn.1679-9836.v100i3p287-293
Guydon, L. C. (1993) · Fordham Research Commons (Fordham University)
Dental Health in a Group of Workers from Timisoara
Păuncu, E.-A., Jebereanu, L., & Gavrilă-Ardelean, L. (2008)
Chest Pain, Dyspnea, Palpitations
Hanna, E. B. (2022) · Wiley eBooks · doi:10.1002/9781119832737.ch27
Detection of atrial fibrillation
Gurp, N. V.-V. (2022) · doi:10.26481/dis.20220325nv
Atrial fibrillation detection service for stroke prevention
Kareem, M. K. (2021) · Sheffield Hallam University · doi:10.7190/shu-thesis-00420
Pfeiffer, S., Meyer, S., Amft, O., Anzai, D., Wang, J., Fischer, G., & Kirchner, J. (2020) · doi:10.36227/techrxiv.13295711
Togawa, T. (2017) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1421.pub2
Pfeiffer, S., Meyer, S., Amft, O., Anzai, D., Wang, J., Fischer, G., & Kirchner, J. (2020) · doi:10.36227/techrxiv.13295711.v1
Screening for Heart Disease in the Age of Digital Health Technologies: Who, When, and How?
Richardson, E., Hall, A., Hare, C., Page, P. L., & Mitchell, A. R. J. (2022) · EMJ Cardiology · doi:10.33590/emjcardiol/22-00093
An Approach to Cardiac Syncope in the Elderly Patient
Roy, P., Walsh, K. E., & Goldberger, Z. D. (2022) · Current Geriatrics Reports · doi:10.1007/s13670-022-00376-y
Health technology assessments of devices drawn on experiences from orphan medicines
Medić, G. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.233715293
30 minute Short Holter Monitoring in Outpatient Practices - New Clues to Diagnosis
Srinivasan, A., Kumar, S., Amrutha, G. R., Vijayalakshmi, K., Padmanabhan, D., & Gopal, S. (2022) · IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT) · doi:10.1109/conecct55679.2022.9865788
An Application-Specific Power Consumption Optimization for Wearable Electrocardiogram Devices
Badr, A., Rashwan, A. M., & Elgazzar, K. (2022) · Conference on Local Computer Networks · doi:10.1109/lcn53696.2022.9843460
Interpretation of electrocardiograms
(2023) · Pharmaceutical journal/The pharmaceutical journal · doi:10.1211/pj.2023.1.176371
Cardiac arrhythmias in adult patients with congental heart disease
Wiktor, D., Mazurek, M., Pabis, P., Średniawa, B., & Jędrzejczyk‐Patej, E. (2023) · In a good rythm · doi:10.5604/01.3001.0053.4021
Development of a Control System for Patients with Ventricular Arrhythmias
Николаевич, К. Д. (2023) · IEEE International Conference on Soft Computing and Measurements (SCM) · doi:10.1109/scm58628.2023.10159084
Human-Centered Design to Enhance the Holter Monitor Experience for Elderly People
Petrocchi, F. (2023) · Studies in big data · doi:10.1007/978-981-99-3989-3_10
Contemporary Considerations in the Evolution of Wearable Technology for Arrhythmia Detection
Joseph, T., Barrie, M., Karimi, A., Haque, S., Ogunmwonyi, I., & Ojha, U. (2023) · Current Cardiology Reviews · doi:10.2174/1573403x19666230811093048
Advancing cardiometabolic monitoring: A hybrid study on smart garments and wearables
Mirkov, M., Kostic, M. D., Kojić, V., & Strbac, M. D. (2023) · Telecommunications Forum (TELFOR) · doi:10.1109/telfor59449.2023.10372807 · Cited by 1
Knox, M. J., Huang, B., Willard‐Grace, R., & Su, G. (2024) · Healthcare · doi:10.1016/j.hjdsi.2023.100732
Development of a Emergency Rescue Device for Patients with Ventricular Arrhythmias
Николаевич, К. Д. (2023) · Systems and Technologies of the Digital HealthCare (STDH) · doi:10.1109/stdh59314.2023.10490972
Destefani, V. C., Vitrio, B., & Destêfani, A. C. (2024) · Brazilian Journal of Implantology and Health Sciences · doi:10.36557/2674-8169.2024v6n8p4312-4331
Parlato, S., Muto, V., & Bifulco, P. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-62520-6_22
Application of Different Types of Electrocardiogram Monitoring in Arrhythmias
Cao, J., Zhang, L., & Tang, B. (2024) · International Journal of Heart Rhythm · doi:10.4103/ijhr.ijhr_6_23
Duplexing Mobile System for Real-time Arrhythmia Detection Using a Deep Learning Model
Kim, S., Lee, H., Park, R., & Won, Y. (2024) · Journal of Digital Contents Society · doi:10.9728/dcs.2024.25.12.3743
Homme, J. L., Kranz, L. A., House, M., & Greenmyer, J. R. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.04.012
Akimoto, Y., Ito, Y., Tsurushima, H., Hosoo, H., Marushima, A., Hayakawa, M., Nakamura, K., Fujita, K., Terakado, T., Yamagami, H., et al. (2025) · Asian Journal of Neurosurgery · doi:10.1055/s-0045-1809050
Nuvvula, S., & Makaryus, A. N. (2025) · Expert Review of Medical Devices · doi:10.1080/17434440.2025.2514005
Miyoshi, M., Kodama, N., Sato, H., Masutomo, K., Kamiunten, H., Shinohara, T., & Takahashi, N. (2025) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.70092
Revuri, N., La, Q. D., Faltas, M., Pryor, F., Aradhya, S., & Kahlam, J. S. (2025) · Cureus · doi:10.7759/cureus.89743 · Cited by 1
Joshi, B., Chun, Y. N., Chakraborty, J., Thomas, G. P., Bolaji, P., Tharin, M. S. K., Adeyeye, R., Adeyeye, E., & Azeta, S. (2025) · Cureus · doi:10.7759/cureus.91448
Research on stack-based LSTM adaptive ECG mapping method
Shen, Y., Li, Y. C., Wang, Y., Lu, T., Cao, R., Wang, H., & Cao, F. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108727
Titus, J., Katz, J., Soto‐Ruiz, K. M., Rh, C., Wu, A. H., Jaffe, A. S., & Peacock, W. F. (2026) · medRxiv · doi:10.64898/2026.01.15.26344213
Mujtaba, G., Javaid, M. H., Baloch, K., Hussain, M. I., & Khalid, M. (2026) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000004751
Introduction to Biosensing Devices
Sharma, A. K. (2026) · Springer eBooks · doi:10.1007/978-981-95-5519-2_1
Richards, M., Garner, J. B., Rogers, J., Mahajan, D., Ravikumar, V., Herrmann, K. L., Schwartz, T., Okeson, B. K., Kupfer, M. E., Stolen, C., et al. (2026) · Heart Rhythm O2 · doi:10.1016/j.hroo.2026.01.026
Patient Perspectives on Episodic Dizziness and a Hypothetical At-Home Diagnostic Tool
Keating, D. P., Steenerson, K. K., Gupta, A., & Maria, P. L. S. (2026) · Journal of Patient Experience · doi:10.1177/23743735261416352
Electrocardiographic Monitoring and Wearables
Azab, M., & Cheung, C. C. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-15734-9.00058-3
Omic approach to atrial fibrillation
Puertas, R. D. (2017) · theses.fr (ABES) · doi:10.70675/dd1855ebz1421z42e4zb00czd5476f4de207
Prescribed Cardiac Wearables in Routine Care: a qualitative study of Patient ExperiencesPreprint
Zeng, A., O’Hagan, E. T., Trivedi, R., Ford, B., Perry, T., Turnbull, S., Sheahen, B., Mulley, J., Sedhom, M., Choy, C. K., et al. (2026) · medRxiv · doi:10.64898/2026.04.09.26350550
Ramezani, A., Maddah, N., Heine, M., Homaei, A., Simeth, L., Mazuera, L., Osho, A. A., Muehlschlegel, J. D., Wollborn, J., & Nezami, F. R. (2026) · Research Square · doi:10.21203/rs.3.rs-9138384/v1
Lu, B., Dong, Q., Desai, S. A., Zhou, H., Tanade, C., Lee, S., & Kang, C. (2026) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp55912.2026.11463615
Lin, D., Kumar, S., Butt, K., Klewer, J., Balakrishnan, M., Altamirano, A. J., Vigdor, A., Schell, A., Parikh, P., Grigoriadis, C. J., et al. (2026) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.70354
Hu, L., & Ji, X. (2026) · British Journal of Hospital Medicine · doi:10.31083/bjhm52968
Jubayel, M., Joya, J. G., Hasan, R., Anik, M. A. R., Islam, M. M., & Islam, M. J. (2025) · International Conference on Computer and Information Technology (ICCIT) · doi:10.1109/iccit68739.2025.11490392
Diagnostic Feature Reconstruction for Enhanced Single-Lead ECG Classification
Qi, C., Guo, Y., Yang, Q., Hu, Y., Chen, Y., Fan, Q., & Chen, K. (2026) · Sensors · doi:10.3390/s26102955
Tan, C., Tamei, T., Ishii, A., Arimoto, N., & Shiotani, H. (2026) · Chronobiology International · doi:10.1080/07420528.2026.2669593
Bradyarrhythmias Associated with Oncologic Treatment—An Updated Review
Stępień, J., Stępniak, J., Ciołek, A., Piotrowski, J., Kryca, A., & Piotrowski, G. (2026) · Cancers · doi:10.3390/cancers18101556
Digital biomarkers in non-communicable diseases
Agha-Mir-Salim, L., Grünewald, E., Balzer, F., & Braune, K. (2026) · Biomarkers · doi:10.1080/1354750x.2026.2682425
Nana, F. A., Razuri-Madrid, A., Cigaran, A., Águila, N. O. D., Tello, B., Gutierrez, A., & Huané, L. Y. C. (2026) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea69746.2026.11537340
Xie, S., Lin, X., Pang, Y., Bai, H., Huang, Y., & Wen, J. (2026) · Research Square · doi:10.21203/rs.3.rs-9982141/v1
Chen, Y., Yu, Q., Xu, H., Zhang, L., Li, W., & Wu, Y. (2026) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm48196
A Comprehensive Review of Next-generation Electrocardiogram Technologies, Trends, and Outlook
Bansal, D., Chaudhary, N., Bansal, P., Sharma, R., & Singh, M. (2026) · Indian Journal of Cardiovascular Disease in Women · doi:10.25259/ijcdw_11_2026
Russo, P., Nathan, R., Shokoohi, M., Hendrickson, E., Boyle, K., Turakhia, M. P., & Wright, B. (2026) · Journal of Medical Economics · doi:10.1080/13696998.2026.2707021
Dzikowicz, D. J., Aktaş, M. K., Horn, R., MacKecknie, B. D., Cutter, K., Mykins, B., Cenname, K., McNitt, S. A., Couderc, J.-P. Y., Strawderman, R. L., et al. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.103102
Shaffer, A., Possti, D., Shmayahu, Y., Barak‐Shinar, D., Beigel, R., Hochstein, D., Haker, R., Hanein, Y., Meiri, H., Vazhgovsky, O., et al. (2026) · Biosensors · doi:10.3390/bios16090481
Tudor, S. S., Tupu, A. E., Munteanu, A. E., Ștefan, C. S., & Ferţu, D. I. (2026) · Healthcare · doi:10.3390/healthcare14182894
Evolutionary Synthesis of QRS Detection Algorithms for Wearable ECG-Based Heartbeat Classification
Reklewski, W., Potoczny, J., & Augustyniak, P. (2026) · Electronics · doi:10.3390/electronics15184269
READ: Reasoning Like a Cardiologist for Contactless Arrhythmia Diagnosis
Lyu, R., Feng, H., Zhou, A., Ma, H., Zheng, M., Meng, X., Duan, J., Wang, J., Zheng, M., & Shao, C. (2026) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3831993
Wearable Heart Rate Monitoring in Resource-Limited Healthcare
Abrori, S. A. (2026) · Advances in computational intelligence and robotics book series · doi:10.4018/979-8-2600-1036-5.ch004
Cardiac Monitors for Unexplained Syncope — More Benefit than Expected?
Probst, M. A. (2026) · New England Journal of Medicine · doi:10.1056/nejme2612346
Metadata
- Authors
- Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J.
- Affiliations
- Scripps Health (US)
- Corresponding author
- Topol, Eric J.
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 127
- Issue
- 1
- Pages
- 95.e11-95.e17
- ISSN
- 0002-9343 (ISSN-L)
- PMC
- PMC3882198
- OpenAlex
- W2079951953
- Semantic Scholar
- 101423c149063dc6c6b0798d5f2e541417d16fbe
- Cited by
- 498
- References
- 20
- Citations by year
- 2026: 35 · 2025: 37 · 2024: 37 · 2023: 33 · 2022: 51 · 2021: 62 · 2020: 38 · 2019: 50 · 2018: 54 · 2017: 50 · 2016: 24 · 2015: 16 · 2014: 9
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- The American Journal of Medicine (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Center for Advancing Translational Sciences (NCT01559246, UL1 TR000109)
- National Institutes of Health
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- arrhythmia detection, 24-hour Holter monitoring, Holter monitoring, single-lead ECG, atrial fibrillation, supraventricular tachycardia, ventricular tachycardia, atrioventricular block
- MeSH terms
- Adhesives, Adult, Aged, Arrhythmias, Cardiac, Atrial Fibrillation, Atrial Flutter, Electrocardiography, Equipment Design, Female, Humans, Male, Middle Aged, Tachycardia, Supraventricular, Time Factors, Ventricular Fibrillation, Electrocardiography, Ambulatory, Patient Satisfaction, Tachycardia, Ventricular, Atrioventricular Block
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review