The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring
Open accessAbstract
BACKGROUND: Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration-cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. METHODS: A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar's tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. RESULTS: Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P < .001). CONCLUSIONS: Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Patch monitors and MCT are the most complete outpatient ECG recording and increase the likelihood for detecting AF, and can provide accurate representation of AF burden for the duration of recording (Barrett et al., 2014;Rosenberg et al., 2013;Rothman et al., 2007;Turakhia et al., 2013;Schreiber et al., 2014).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Barrett et al., 2014
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Ambulatory ECG monitoring can be considered to establish a diagnosis or make a symptom-rhythm correlation, with longer term monitoring resulting in higher yield [1,4] .( Table 2 )”
From Evaluating and managing bradycardia (2020) · cites this paper as [4]
In the citing paper
“Although most of these devices are only single lead, they can be as effective or even exceed the ability of conventional Holter monitoring to detect arrhythmias owing to their convenient usability over longer periods of time55,56.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [55]
In the citing paper
“Several patientoperated devices 136,137 and extended continuous ECG monitoring using skin patch recorders 138 have been validated for detection of paroxysmal AF. 139”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [138]
In the citing paper
“Our study examined a more recent time period than prior investigations of long-term continuous monitors [5, 9] and suggests that changes in the device technology and accumulated operator experience may have resulted in improved patient compliance.”
From Incidence and timing of potentially high-risk arrhythmias detected through long term continuous ambulatory electrocardiographic monitoring (2016) · cites this paper as [5]
In the citing paper
“In another study by Barrett PM et al24 it was shown that adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (P < .001), although the Holter monitor detected more events during the initial 24‐h monitoring period (P = .013).”
From Portable out-of-hospital electrocardiography: A review of current technologies (2018) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318282ab8f · Cited by 1,294
Robinson, R. (1993) · BMJ · doi:10.1136/bmj.307.6907.793 · Cited by 819
Kim, M. H., Johnston, S. S., Chu, B. C., Dalal, M. R., & Schulman, K. L. (2011) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.958165 · Cited by 798
Jabaudon, D., Sztajzel, J. M., Sievert, K., Landis, T., & Sztajzel, R. F. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Occult Atrial Fibrillation in Cryptogenic Stroke
Ritter, M., Kochhäuser, S., Duning, T., Reinke, F., Pott, C., Dechering, D. G., Eckardt, L., & Ringelstein, E. B. (2013) · Stroke · doi:10.1161/strokeaha.111.676189 · Cited by 180
Cited by
Sorted by citations
Items 101–200 of 496
Michard, F., & Sessler, D. I. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.07.032 · Cited by 46
Wearable biosensors for cardiovascular monitoring leveraging nanomaterials
Chen, X., Manshaii, F., Tioran, K., Wang, S., Zhou, Y., Zhao, J., Yang, M., Yin, X., Liu, S., & Wang, K. (2024) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-00906-6 · Cited by 52
Cardiac electrical instability in newly diagnosed/chronic epilepsy tracked by Holter and ECG patch
Pang, T. D., Nearing, B. D., Krishnamurthy, K. B., Olin, B., Schachter, S. C., & Verrier, R. L. (2019) · Neurology · doi:10.1212/wnl.0000000000008077 · Cited by 44
(2020) · PubMed Central · doi:10.6515/acs.202005_36(3).20190903a · Cited by 44
Yang, C., Fan, F., Aranoff, N. D., Green, P., Li, Y., Liu, C., & Tavassolian, N. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.750221 · Cited by 44
Transforming the care of atrial fibrillation with mobile health
Turakhia, M. P., & Kaiser, D. W. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-016-0136-3 · Cited by 44
Thijs, V. (2017) · Stroke · doi:10.1161/strokeaha.117.017083 · Cited by 43
Kido, K., TAMURA, T., Ono, N., Altaf‐Ul‐Amin, M., Sekine, M., Kanaya, S., & Huang, M. (2019) · Sensors · doi:10.3390/s19071731 · Cited by 43
Kędzierski, K., Radziejewska, J., Sławuta, A., Wawrzyńska, M., & Arkowski, J. (2022) · Medicina · doi:10.3390/medicina58020210 · Cited by 50
Wearable Devices for Arrhythmia Detection: Advancements and Clinical Implications
Abdelrazik, A., Eldesouky, M., Antoun, I., Lau, E. Y. M., Koya, A. I., Vali, Z., Suleman, S. A., Donaldson, J., & Ng, G. A. (2025) · Sensors · doi:10.3390/s25092848 · Cited by 57
Screening for Atrial Fibrillation Using Economical and Accurate Technology (From the SAFETY Study)
Lown, M. T., YUE, A. M., Shah, B. N., Corbett, S. J., Lewith, G. T., Stuart, B. L., Garrard, J., Brown, M. E., Little, P. S., & Moore, M. V. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.07.003 · Cited by 42
Carrington, M., Providencia, R. A., Chahal, C. A. A., Ricci, F., Epstein, A. E., Gallina, S., Fedorowski, A., Sutton, R., & Khanji, M. Y. (2022) · European Heart Journal Open · doi:10.1093/ehjopen/oeac072 · Cited by 43
Ambulatory screening tool for sleep apnea: analyzing a single-lead electrocardiogram signal (ECG)
Magnúsdóttir, S., & Hilmisson, H. (2017) · Sleep And Breathing · doi:10.1007/s11325-017-1566-6 · Cited by 41
An Independent Component Analysis Approach to Motion Noise Cancelation of Cardio-Mechanical Signals
Yang, C., & Tavassolian, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2856700 · Cited by 41
Evaluation of Wearable Digital Devices in a Phase I Clinical Trial
Izmailova, E. S., McLean, L., Bhatia, G., Hather, G., Cantor, M., Merberg, D., Perakslis, E. D., Benko, C., & Wagner, J. A. (2019) · Clinical and Translational Science · doi:10.1111/cts.12602 · Cited by 41
Comparison of Holter With Zio Patch Electrocardiography Monitoring in Children
Bolourchi, M., Silver, E. S., Muwanga, D., Mendez, E., & Liberman, L. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.11.028 · Cited by 41
Artificial intelligence for direct-to-physician reporting of ambulatory electrocardiography
Johnson, L., Zadrozniak, P., Jasina, G., Grotek, A., Andrade, J. G., Svennberg, E., Diederichsen, S. Z., McIntyre, W. F., Stavrakis, S., Benezet‐Mazuecos, J., et al. (2025) · Nature Medicine · doi:10.1038/s41591-025-03516-x · Cited by 47
Ambulatory Arrhythmia Detection with ZIO® XT Patch in Pediatric Patients: A Comparison of Devices
Pradhan, S., Robinson, J. A., Shivapour, J., & Snyder, C. S. (2019) · Pediatric Cardiology · doi:10.1007/s00246-019-02089-0 · Cited by 40
Santala, O. E., Halonen, J., Martikainen, S., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Laitinen, T. P., Laitinen, T. M., Väliaho, E., Hartikainen, J. E. K., et al. (2021) · JMIR mhealth and uhealth · doi:10.2196/29933 · Cited by 40
Bladder Monitoring Systems: State of the Art and Future Perspectives
Semproni, F., Iacovacci, V., & Menciassi, A. (2022) · IEEE Access · doi:10.1109/access.2022.3221816 · Cited by 42
Motion-unrestricted dynamic electrocardiogram system utilizing imperceptible electronics
Li, D., Cui, T., Liu, J., Shao, W., Liu, X., Chen, Z., Xu, Z., Li, X., Xu, S., Xie, Z., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-58390-5 · Cited by 44
Turchioe, M. R., Baik, D., Beauchemin, M., Hickey, K. T., & Merrill, J. A. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1672138 · Cited by 40
Karaoğuz, M. R., Yurtseven, E., Aslan, G., Deliormanlı, B. G., Adıgüzel, Ö., Gönen, M., Li, K.-M., & Yılmaz, E. N. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.02.012 · Cited by 39
Tadi, M. J., Mehrang, S., Kaisti, M., Lahdenoja, O., Hurnanen, T., Jaakkola, J., Jaakkola, S., Vasankari, T., Kiviniemi, T., Airaksinen, J. K. E., et al. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2882874 · Cited by 38
Izmailova, E. S., McLean, L., Hather, G., Merberg, D., Homsy, J. G., Cantor, M., Volfson, D., Bhatia, G., Perakslis, E. D., Benko, C., et al. (2019) · Clinical and Translational Science · doi:10.1111/cts.12673 · Cited by 38
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12461 · Cited by 37
Kwon, S., Lee, S., Choi, E., Ahn, H., Song, H. S., Lee, Y.-S., Oh, S., & Lip, G. Y. H. (2022) · Journal of Medical Internet Research · doi:10.2196/37970 · Cited by 37
Xue, X., Hu, J., Xiang, D., Li, H., Jiang, Y., Fang, W., Yan, H., Chen, J., Wang, W., Su, X., et al. (2023) · Canadian Medical Association Journal · doi:10.1503/cmaj.220929 · Cited by 37
Biocompatible Electronic Skins for Cardiovascular Health Monitoring
Du, Y., Kim, J. H., Kong, H., Li, A. A., Jin, M., Kim, D. H., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303461 · Cited by 37
Are heart rate monitors valuable tools for diagnosing arrhythmias in endurance athletes?
Gajda, R., Biernacka, E. K., & Drygas, W. (2017) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12917 · Cited by 37
Barnes, L. D., Lee, K., Kempa-Liehr, A. W., & Hallum, L. E. (2022) · PLoS ONE · doi:10.1371/journal.pone.0272167 · Cited by 43
Biointerfaced sensors for biodiagnostics
Zohar, O., Khatib, M., Omar, R., Vishinkin, R., Broza, Y. Y., & Haick, H. (2021) · Open Research (University of Surrey) · doi:10.1002/viw.20200172 · Cited by 36
Design and Implementation of an Ultralow-Power ECG Patch and Smart Cloud-Based Platform
Baraeinejad, B., Shayan, M. F., Vazifeh, A. R., Rashidi, D., Hamedani, M. S., Tavolinejad, H., Gorji, P., Razmara, P., Vaziri, K., Vashaee, D., et al. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3164151 · Cited by 36
Dilaveris, P., Antoniou, C. K., Caiani, E. G., Casado-Arroyo, R., Climent, A. M., Cluitmans, M. J. M., Cowie, M., Doehner, W., Guerra, F., Jensen, M. T., et al. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac026 · Cited by 40
Arrhythmia in hemodialysis patients and its relation to sudden death
Kalra, P. A., Green, D., & Poulikakos, D. J. (2018) · Kidney International · doi:10.1016/j.kint.2017.12.005 · Cited by 35
Bolourchi, M., & Batra, A. S. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.12.014 · Cited by 34
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.005 · Cited by 34
Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device
SAYER, G. T., Piper, G. L., Vorovich, E., Raikhelkar, J., Kim, G. H., Rodgers, D. E., Shimbo, D., & Uriel, N. Y. (2022) · American Journal of Hypertension · doi:10.1093/ajh/hpac020 · Cited by 34
Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring
Torfs, T., Smeets, C. J. P. P., Geng, D., Berset, T., der Auwera, J. V., Vandervoort, P. M., & Grieten, L. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.08.012 · Cited by 33
Automatic Real-Time Embedded QRS Complex Detection for a Novel Patch-Type Electrocardiogram Recorder
Saadi, D. B., Tanev, G., Flintrup, M., Osmanagic, A., Egstrup, K., Hoppe, K., Jennum, P., Jeppesen, J., Iversen, H. K., & Sørensen, H. B. D. (2015) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2015.2421901 · Cited by 33
Two-Week Burden of Arrhythmias across CKD Severity in a Large Community-Based Cohort: The ARIC Study
Kim, E. D., Soliman, E. Z., Coresh, J., Matsushita, K., & Chen, L. Y. (2020) · Journal of the American Society of Nephrology · doi:10.1681/asn.2020030301 · Cited by 34
Spooner, M. T., Messe, S. R., Chaturvedi, S., Do, M. M., Gluckman, T. J., Han, J. K., Russo, A. M., Saxonhouse, S. J., & Wiggins, N. B. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.10.100 · Cited by 38
Validation of a genetic risk score for atrial fibrillation: A prospective multicenter cohort study
Muse, E. D., Wineinger, N. E., Spencer, E. G., Peters, M., Henderson, R., Zhang, Y., Barrett, P. M., Rivera, S. P., Wohlgemuth, J. G., Devlin, J. J., et al. (2018) · PLoS Medicine · doi:10.1371/journal.pmed.1002525 · Cited by 32
Self-citationImpact of Mobile Health Devices for the Detection of Atrial Fibrillation: Systematic Review
Biersteker, T. E., Schalij, M. J., & Treskes, R. W. (2021) · JMIR mhealth and uhealth · doi:10.2196/26161 · Cited by 34
Kwon, S., Lee, S., Choi, E., Ahn, H., Song, H.-S., Lee, Y.-S., & Oh, S. (2021) · Sensors · doi:10.3390/s21093122 · Cited by 32
Home Monitoring of Age-Related Macular Degeneration
Yu, H. J., Kiernan, D. F., Eichenbaum, D. A., Sheth, V. S., & Wykoff, C. C. (2020) · Ophthalmology Retina · doi:10.1016/j.oret.2020.08.003 · Cited by 31
Digital monitoring and care: Virtual medicine
Shinbane, J. S., & Saxon, L. A. (2016) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2016.05.007 · Cited by 31
Han, J. K., Al-Khatib, S. M., & Albert, C. M. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.12.001 · Cited by 29
Nonsustained ventricular tachycardia in heart failure with preserved ejection fraction
Gutiérrez, A., Ash, J., Akdemir, B., Alexy, T., Cogswell, R. J., Chen, J., & Adabağ, S. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14043 · Cited by 30
Choi, W., Kim, S., Lee, W., Kang, S., Yoon, C., Youn, T., & Chae, I. (2020) · Journal of Korean Medical Science · doi:10.3346/jkms.2020.35.e363 · Cited by 30
Signal Quality Analysis for Long-Term ECG Monitoring Using a Health Patch in Cardiac Patients
Campero-Jurado, I., Lorato, I. R., Morales, J., Fruytier, L., Stuart, S., Panditha, P., Janssen, D. M., Rossetti, N., Uzunbajakava, N. E., Șerban, I. B., et al. (2023) · Sensors · doi:10.3390/s23042130 · Cited by 30
Goyal, P., & Maurer, M. S. (2016) · PubMed Central · doi:10.11909/j.issn.1671-5411.2016.05.002 · Cited by 34
Transformation in Healthcare by Wearable Devices for Diagnostics and Guidance of Treatment
Mahajan, A., Pottie, G. J., & Kaiser, W. (2020) · ACM Transactions on Computing for Healthcare · doi:10.1145/3361561 · Cited by 30
Barrea, L., Vetrani, C., Caprio, M., Cataldi, M., Ghoch, M. E., Elce, A., Camajani, E., Verde, L., Savastano, S., Colao, A., et al. (2022) · Current Obesity Reports · doi:10.1007/s13679-022-00475-z · Cited by 33
McIntyre, W. F., Vadakken, M. E., Connolly, S. J., Mendoza, P. A., Lengyel, A. P., Rai, A. S., Latendresse, N. R., Grinvalds, A., Ramasundarahettige, C. F., Acosta, J. G., et al. (2023) · Annals of Internal Medicine · doi:10.7326/m23-1411 · Cited by 30
Technology platforms for remote monitoring of vital signs in the new era of telemedicine
Zhao, F., Li, M., & Tsien, J. Z. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1050957 · Cited by 31
Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2018-207570 · Cited by 28
A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems
Sohn, K., Merchant, F. M., Sayadi, O., Puppala, D., Doddamani, R., Sahani, A. K., Singh, J. P., Heist, E. K., Isselbacher, E. M., & Armoundas, A. A. (2017) · Scientific Reports · doi:10.1038/srep44946 · Cited by 28
Kim, J. Y., Oh, I., Lee, H., Lee, J. H., Cho, Y., Gil, Y., Jung, S., Kim, D. I., Shin, M. G., Yoo, J. Y., et al. (2023) · Journal of Arrhythmia · doi:10.1002/joa3.12865 · Cited by 26
Critical review of electrocardiography measurement systems and technology
Kalra, A. M., Lowe, A., & Al‐Jumaily, A. M. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaf2b7 · Cited by 27
Shi, J., Wang, F., Qin, M., Chen, A., Liu, W., He, J. L., Wang, H., Chang, S., & Huang, Q. (2022) · Biosensors · doi:10.3390/bios12070524 · Cited by 27
An adaptive QRS detection algorithm for ultra-long-term ECG recordings
Malik, J., Soliman, E. Z., & Wu, H. (2020) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2020.02.016 · Cited by 27
McIntyre, W. F., Wang, J., Benz, A. P., Johnson, L., Connolly, S. J., Gelder, I. C. V., Lópes, R. D., Gold, M. R., Hohnloser, S. H., Lau, C., et al. (2021) · EP Europace · doi:10.1093/europace/euab324 · Cited by 26
Zaman, N., Ong, J., Waisberg, E., Masalkhi, M., Lee, A. G., Tavakkoli, A., & Zuckerbrod, S. L. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03379-8 · Cited by 25
Ambulatory ECG monitoring in the age of smartphones
Sanders, D. J., Ungar, L. D. J., Eskander, M., & Seto, A. H. (2019) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.86a.18123 · Cited by 26
Breathable, Wireless, Thin-Film Wearable Biopatch Using Noise-Reduction Mechanisms
Rodeheaver, N., Kim, H., Herbert, R., Seo, H., & Yeo, W. (2022) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.1c01107 · Cited by 25
Artificial intelligence to aid the detection of mood disorders
Cummins, N., Matcham, F., Klapper, J., & Schuller, B. W. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817133-2.00010-0 · Cited by 25
Materials Advances in Devices for Heart Disease Interventions
Jalandhra, G. K., Srethbhakdi, L., Davies, J., Nguyen, C. C., Phan, P. T., Och, Z., Ashok, A., Lim, K. S., Phan, H., Do, T. N., et al. (2025) · Advanced Materials · doi:10.1002/adma.202420114 · Cited by 23
Cardiac monitoring for patients with palpitations
Pascual, J. F., Romero, J. C., Pérez‐Rodon, J., Benito, B., Santos‐Ortega, A., Maldonado, J., González, I. F., & Rivas‐Gándara, N. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i11.608 · Cited by 23
Recent Advances in Materials and Flexible Sensors for Arrhythmia Detection
Guess, M., Zavanelli, N., & Yeo, W. (2022) · Materials · doi:10.3390/ma15030724 · Cited by 26
Karunadas, C. P., & Mathew, C. (2019) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2019.12.013 · Cited by 23
2020 Clinical practice guidelines for Supraventricular tachycardia in adults
Bokeria, L. A., Golukhova, E. Z., Popov, S. V., Artyukhina, Е. А., Базаев, В. А., Batalov, R. E., Bokeria, O. L., Vygovsky, A. B., Gilyarov, M. Y., Sp, G., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4484 · Cited by 23
Wearable-basierte Detektion von Arrhythmien
Veltmann, C., Ehrlich, J. R., Gassner, U. M., Meder, B., Möckel, M. M., Radke, P. W., Scholz, E., Schneider, H., Stellbrink, C., & Duncker, D. (2021) · Der Kardiologe · doi:10.1007/s12181-021-00488-3 · Cited by 23
Nadarajah, R., Wahab, A., Reynolds, C., Raveendra, K., Askham, D., Dawson, R. L., Keene, J., Shanghavi, S., Lip, G. Y. H., Hogg, D., et al. (2023) · Open Heart · doi:10.1136/openhrt-2023-002447 · Cited by 22
Single-lead f-wave extraction using diffusion geometry
Malik, J., Reed, N., Wang, C., & Wu, H. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa707c · Cited by 22
Comparison of 2 ambulatory patch ECG monitors: The benefit of the P-wave and signal clarity
Rho, R. W., Vossler, M. R., Blancher, S., & Poole, J. E. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.03.022 · Cited by 21
Rate control strategies for atrial fibrillation
Alobaida, M., & Alrumayh, A. (2021) · Annals of Medicine · doi:10.1080/07853890.2021.1930137 · Cited by 28
2020 Clinical practice guidelines for Bradyarrhythmias and conduction disorders
Revishvili, A. S., Artyukhina, Е. А., Глезер, М. Г., Базаев, В. А., Batalov, R. E., Bokeria, L. A., Bokeria, O. L., Davtyan, K. V., Ivanitsky, E. A., Ковалев, А. С., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4448 · Cited by 28
Marcelli, E., Capucci, A., Minardi, G., & Cercenelli, L. (2016) · ASAIO Journal · doi:10.1097/mat.0000000000000446 · Cited by 22
Wave-shape oscillatory model for nonstationary periodic time series analysis
Lin, Y.-T., Malik, J., & Wu, H. (2021) · Foundations of Data Science · doi:10.3934/fods.2021009 · Cited by 21
Sharma, A. N., & Baranchuk, A. M. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.003 · Cited by 20
Detecting and monitoring arrhythmia recurrence following catheter ablation of atrial fibrillation
Ajijola, O. A., Boyle, N. G., & Shivkumar, K. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00090 · Cited by 20
Aronsson, M., Svennberg, E., Rosenqvist, M., Engdahl, J., Al‐Khalili, F., Friberg, L., Frykman, V., & Levin, L. (2017) · EP Europace · doi:10.1093/europace/eux002 · Cited by 20
A new approach for analysis of heart rate variability and QT variability in long-term ECG recording
Wu, H., & Soliman, E. Z. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0490-8 · Cited by 20
A Cloud-Connected Multi-Lead Electrocardiogram (ECG) Sensor Ring
Dong, Q., Downen, R. S., Li, B., Tran, N. A., & Li, Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3075992 · Cited by 20
Computational Electrocardiography: Revisiting Holter ECG Monitoring
Marx, N., & Deserno, T. M. (2016) · Methods of Information in Medicine · doi:10.3414/me15-05-0009 · Cited by 20
Personalized Neural Network for Patient-Specific Health Monitoring in IoT: A Metalearning Approach
Jia, Z., Shi, Y., & Hu, J. (2022) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/tcad.2022.3162182 · Cited by 20
Zhang, M., Guo, N., Gao, Q., Li, H., & Wang, Z. (2022) · Sensors · doi:10.3390/s22155472 · Cited by 19
Clinical Implications of Technological Advances in Screening for Atrial Fibrillation
Singh, N., Chun, S., Hadley, D., & Froelicher, V. F. (2018) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2018.01.007 · Cited by 19
Robust Heartbeat Classification for Wearable Single-Lead ECG via Extreme Gradient Boosting
Zhu, H., Zhao, Y., Pan, Y., Xie, H., Wu, F., & Huan, R. (2021) · Sensors · doi:10.3390/s21165290 · Cited by 19
(2017) · PubMed Central · Cited by 19
Heart rate variability in patients with cardiovascular diseases
Khan, M. S., Javaid, S. S., Mentz, R. J., Lindenfeld, J., Wu, H., Prochaska, J. H., Johansen, J. B., Wild, P. S., Linz, D., Dinh, W., et al. (2025) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2025.06.003 · Cited by 20
Huang, Y., Liu, H., Wu, C., Fang, L., Fang, Q., Wang, Q., Fei, Y., Guo, X., & Zhang, S. (2020) · Lara D. Veeken · doi:10.1093/rheumatology/keaa872 · Cited by 18
Upregulated miR-328-3p and its high risk in atrial fibrillation
Huang, H., Chen, H., Liang, X., Chen, X., Chen, X., & Chen, C. (2022) · Medicine · doi:10.1097/md.0000000000028980 · Cited by 18
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 19
Textile Integrated Wearable Technologies for Sports and Medical Applications
Leutheuser, H., Lang, N. R., Gradl, S., Struck, M., Tobola, A., Hofmann, C., Anneken, L., & Eskofier, B. M. (2017) · Human-computer interaction series · doi:10.1007/978-3-319-50124-6_16 · Cited by 18
Evidence-Based Approach to Palpitations
Weinstock, C., Wagner, H., Snuckel, M., & Katz, M. (2020) · Medical Clinics of North America · doi:10.1016/j.mcna.2020.09.004 · Cited by 19
Reed, M. J., Grubb, N. R., Lang, C. C., O’Brien, R., Simpson, K., Padarenga, M., Grant, A., & Tuck, S. (2018) · Trials · doi:10.1186/s13063-018-3098-1 · Cited by 17
Reynolds, M. R., PASSMAN, R. S., Swindle, J. P., Mohammadi, I., Wright, B., Boyle, K., Turakhia, M. P., & Mittal, S. (2023) · American Heart Journal · doi:10.1016/j.ahj.2023.12.002 · Cited by 17
Evaluation of syncope: focus on diagnosis and treatment of neurally mediated syncope
Lee, A. K. Y., & Krahn, A. D. (2016) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2016.1164034 · Cited by 19
Metadata
- Authors
- Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J.
- Affiliations
- Scripps Health (US)
- Corresponding author
- Topol, Eric J.
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 127
- Issue
- 1
- Pages
- 95.e11-95.e17
- ISSN
- 0002-9343 (ISSN-L)
- PMC
- PMC3882198
- OpenAlex
- W2079951953
- Semantic Scholar
- 101423c149063dc6c6b0798d5f2e541417d16fbe
- Cited by
- 498
- References
- 20
- Citations by year
- 2026: 35 · 2025: 37 · 2024: 37 · 2023: 33 · 2022: 51 · 2021: 62 · 2020: 38 · 2019: 50 · 2018: 54 · 2017: 50 · 2016: 24 · 2015: 16 · 2014: 9
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- The American Journal of Medicine (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Center for Advancing Translational Sciences (NCT01559246, UL1 TR000109)
- National Institutes of Health
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- arrhythmia detection, 24-hour Holter monitoring, Holter monitoring, single-lead ECG, atrial fibrillation, supraventricular tachycardia, ventricular tachycardia, atrioventricular block
- MeSH terms
- Adhesives, Adult, Aged, Arrhythmias, Cardiac, Atrial Fibrillation, Atrial Flutter, Electrocardiography, Equipment Design, Female, Humans, Male, Middle Aged, Tachycardia, Supraventricular, Time Factors, Ventricular Fibrillation, Electrocardiography, Ambulatory, Patient Satisfaction, Tachycardia, Ventricular, Atrioventricular Block
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review