The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring
Open accessAbstract
BACKGROUND: Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration-cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. METHODS: A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar's tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. RESULTS: Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P < .001). CONCLUSIONS: Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Patch monitors and MCT are the most complete outpatient ECG recording and increase the likelihood for detecting AF, and can provide accurate representation of AF burden for the duration of recording (Barrett et al., 2014;Rosenberg et al., 2013;Rothman et al., 2007;Turakhia et al., 2013;Schreiber et al., 2014).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Barrett et al., 2014
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Ambulatory ECG monitoring can be considered to establish a diagnosis or make a symptom-rhythm correlation, with longer term monitoring resulting in higher yield [1,4] .( Table 2 )”
From Evaluating and managing bradycardia (2020) · cites this paper as [4]
In the citing paper
“Although most of these devices are only single lead, they can be as effective or even exceed the ability of conventional Holter monitoring to detect arrhythmias owing to their convenient usability over longer periods of time55,56.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [55]
In the citing paper
“Several patientoperated devices 136,137 and extended continuous ECG monitoring using skin patch recorders 138 have been validated for detection of paroxysmal AF. 139”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [138]
In the citing paper
“Our study examined a more recent time period than prior investigations of long-term continuous monitors [5, 9] and suggests that changes in the device technology and accumulated operator experience may have resulted in improved patient compliance.”
From Incidence and timing of potentially high-risk arrhythmias detected through long term continuous ambulatory electrocardiographic monitoring (2016) · cites this paper as [5]
In the citing paper
“In another study by Barrett PM et al24 it was shown that adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (P < .001), although the Holter monitor detected more events during the initial 24‐h monitoring period (P = .013).”
From Portable out-of-hospital electrocardiography: A review of current technologies (2018) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318282ab8f · Cited by 1,294
Robinson, R. (1993) · BMJ · doi:10.1136/bmj.307.6907.793 · Cited by 819
Kim, M. H., Johnston, S. S., Chu, B. C., Dalal, M. R., & Schulman, K. L. (2011) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.958165 · Cited by 798
Jabaudon, D., Sztajzel, J. M., Sievert, K., Landis, T., & Sztajzel, R. F. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Occult Atrial Fibrillation in Cryptogenic Stroke
Ritter, M., Kochhäuser, S., Duning, T., Reinke, F., Pott, C., Dechering, D. G., Eckardt, L., & Ringelstein, E. B. (2013) · Stroke · doi:10.1161/strokeaha.111.676189 · Cited by 180
ROSENBERG, M. A., SAMUEL, M., THOSANI, A., & ZIMETBAUM, P. J. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12053 · Cited by 179
Use of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177
Sivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00233-x · Cited by 160
Zimetbaum, P. J., Kim, K. Y., Josephson, M. E., Goldberger, A. L., & Cohen, D. J. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-11-199806010-00002 · Cited by 133
Reiffel, J. A., Schwarzberg, R., & Murry, M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.01.025 · Cited by 131
A controlled clinical trial in 1809?
Milne, I., & Chalmers, I. (2002) · Journal of Epidemiology & Community Health · doi:10.1136/jech.56.1.1-a · Cited by 113
Joshi, A. K., Kowey, P. R., Prystowsky, E. N., Benditt, D. G., Cannom, D. S., Pratt, C. M., McNamara, A., & Sangrigoli, R. M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.12.015 · Cited by 110
OLSON, J. A., FOUTS, A. M., PADANILAM, B. J., & PRYSTOWSKY, E. N. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00779.x · Cited by 59
Scherr, D., Dalal, D., Henrikson, C. A., Spragg, D. D., Berger, R. D., Calkins, H., & Cheng, A. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9251-0 · Cited by 45
Stroke prevention in atrial fibrillation
Hart, R. G. (2000) · Current Cardiology Reports · doi:10.1007/s11886-000-0025-2 · Cited by 23
Cited by
Sorted by citations
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,439
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Gelder, I. C. V., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., Potter, T. J. R. D., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,507
Al‐Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T. M., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,902
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Metadata
- Authors
- Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J.
- Affiliations
- Scripps Health (US)
- Corresponding author
- Topol, Eric J.
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 127
- Issue
- 1
- Pages
- 95.e11-95.e17
- ISSN
- 0002-9343 (ISSN-L)
- PMC
- PMC3882198
- OpenAlex
- W2079951953
- Semantic Scholar
- 101423c149063dc6c6b0798d5f2e541417d16fbe
- Cited by
- 498
- References
- 20
- Citations by year
- 2026: 35 · 2025: 37 · 2024: 37 · 2023: 33 · 2022: 51 · 2021: 62 · 2020: 38 · 2019: 50 · 2018: 54 · 2017: 50 · 2016: 24 · 2015: 16 · 2014: 9
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- The American Journal of Medicine (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Center for Advancing Translational Sciences (NCT01559246, UL1 TR000109)
- National Institutes of Health
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- arrhythmia detection, 24-hour Holter monitoring, Holter monitoring, single-lead ECG, atrial fibrillation, supraventricular tachycardia, ventricular tachycardia, atrioventricular block
- MeSH terms
- Adhesives, Adult, Aged, Arrhythmias, Cardiac, Atrial Fibrillation, Atrial Flutter, Electrocardiography, Equipment Design, Female, Humans, Male, Middle Aged, Tachycardia, Supraventricular, Time Factors, Ventricular Fibrillation, Electrocardiography, Ambulatory, Patient Satisfaction, Tachycardia, Ventricular, Atrioventricular Block
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review