The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, when the MCHX works in the winter, the frost will form and accumulate faster on the fin surface [6,7], which will lead to a decrease in airflow rate and an increase in the thermal resistance, thus reducing the heating capacities of the heat pump units [8][9][10].”
From Performance Improvement of Microchannel Heat Exchangers with Modified Louver Fins under Frosting Conditions (2023) · cites this paper as [7]
In the citing paper
“Previous studies have shown that the frosting time of MCHX is 20 -50% shorter than that of conventional FTHX [11,12].”
In the citing paper
“Shao et al. [12] claimed that uneven refrigerant distribution was the main factor affecting the frosting performance of the MCHX heat pump system.”
In the citing paper
“revealed that refrigerant distribution in the microchannel heat exchangers is the key factor for microchannel heat pump thermal performance during the frost period.”
In the citing paper
“They reported that the frost period of the finned-tube heat pump system was much longer than that of the microchannel heat pump system”
Citations
Cites
Lemmon, E. W., Huber, M. L., & McLinden, M. O. (2007) · Cited by 4,207
New equations for heat and mass transfer in turbulent pipe and channel flow
Gnielinski, V. (1976) · Medical Entomology and Zoology · Cited by 4,037
Analysis of heat and mass transfer
Eckert, E. R. G., & Drake, R. M. (1971) · Medical Entomology and Zoology · Cited by 1,977
A general correlation for flow boiling in tubes and annuli
Gungor, K., & Winterton, R. H. S. (1986) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(86)90205-x · Cited by 1,291
Reference Fluid Thermodynamic and Transport Properties (REFPROP)
Lemmon, E. W. (2007) · Medical Entomology and Zoology · Cited by 991
Evaporation heat transfer and pressure drop of refrigerant R-134a in a small pipe
Yan, Y.-Y., & Lin, T. (1998) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(98)00127-6 · Cited by 380
Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers
Kim, M.-H., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00025-1 · Cited by 280
Yao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Evaporative heat transfer and pressure drop of R410A in microchannels
Yun, R., Heo, J. H., & Kim, Y. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.08.005 · Cited by 159
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
Research works printed but not linked: 2
- Kim, 2003, Performance comparisons of a unitary split system using microchannel and fin-tube outdoor coils, ASHRAE Trans, 109, 219
- Cavallini, 2002, In-tube condensation of halogenated refrigerants, ASHRAE Trans, 108, 146
Cited by
Sorted by citations
A review of heat transfer and pressure drop characteristics of single and two-phase microchannels
Asadi, M., Xie, G., & Sunden, B. A. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.07.090 · Cited by 245
A comprehensive review on microchannel heat sinks for electronics cooling
Yu, Z.-B., Li, M.-T., & Cao, B.-Y. (2023) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad12d4 · Cited by 286
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218
Review of energy efficiency and system performance of residential heat pump water heaters
Willem, H., Lin, Y., & Lekov, A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.023 · Cited by 199
Wang, H., Peterson, R., Harada, K. J., Miller, E., Ingram-Goble, R., Fisher, L., Yih, J., & Ward, C. (2010) · Energy · doi:10.1016/j.energy.2010.10.020 · Cited by 181
Metadata
- Authors
- Shao, L.-L., Yang, L., & Zhang, C.-L.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Zhang, Chun-Lu
- ORCID
- Zhang, Chun-Lu
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2010-04
- Volume
- 87
- Issue
- 4
- Pages
- 1187-1197
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2157064791
- Cited by
- 112
- References
- 32
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 9 · 2023: 9 · 2022: 10 · 2021: 11 · 2020: 6 · 2019: 7 · 2018: 5 · 2017: 7 · 2016: 9 · 2015: 4 · 2014: 4 · 2013: 3 · 2012: 8
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- heat pumps, microchannel heat exchangers, finned tube heat exchanger, evaporator performance, fan speed, fin density, refrigerant charge reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review