The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, when the MCHX works in the winter, the frost will form and accumulate faster on the fin surface [6,7], which will lead to a decrease in airflow rate and an increase in the thermal resistance, thus reducing the heating capacities of the heat pump units [8][9][10].”
From Performance Improvement of Microchannel Heat Exchangers with Modified Louver Fins under Frosting Conditions (2023) · cites this paper as [7]
In the citing paper
“Previous studies have shown that the frosting time of MCHX is 20 -50% shorter than that of conventional FTHX [11,12].”
In the citing paper
“Shao et al. [12] claimed that uneven refrigerant distribution was the main factor affecting the frosting performance of the MCHX heat pump system.”
In the citing paper
“revealed that refrigerant distribution in the microchannel heat exchangers is the key factor for microchannel heat pump thermal performance during the frost period.”
In the citing paper
“They reported that the frost period of the finned-tube heat pump system was much longer than that of the microchannel heat pump system”
Citations
Cites
Lemmon, E. W., Huber, M. L., & McLinden, M. O. (2007) · Cited by 4,207
New equations for heat and mass transfer in turbulent pipe and channel flow
Gnielinski, V. (1976) · Medical Entomology and Zoology · Cited by 4,037
Analysis of heat and mass transfer
Eckert, E. R. G., & Drake, R. M. (1971) · Medical Entomology and Zoology · Cited by 1,977
A general correlation for flow boiling in tubes and annuli
Gungor, K., & Winterton, R. H. S. (1986) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(86)90205-x · Cited by 1,291
Reference Fluid Thermodynamic and Transport Properties (REFPROP)
Lemmon, E. W. (2007) · Medical Entomology and Zoology · Cited by 991
Evaporation heat transfer and pressure drop of refrigerant R-134a in a small pipe
Yan, Y.-Y., & Lin, T. (1998) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(98)00127-6 · Cited by 380
Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers
Kim, M.-H., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00025-1 · Cited by 280
Yao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Evaporative heat transfer and pressure drop of R410A in microchannels
Yun, R., Heo, J. H., & Kim, Y. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.08.005 · Cited by 159
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
Research works printed but not linked: 2
- Kim, 2003, Performance comparisons of a unitary split system using microchannel and fin-tube outdoor coils, ASHRAE Trans, 109, 219
- Cavallini, 2002, In-tube condensation of halogenated refrigerants, ASHRAE Trans, 108, 146
Cited by
Sorted by citations
A review of heat transfer and pressure drop characteristics of single and two-phase microchannels
Asadi, M., Xie, G., & Sunden, B. A. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.07.090 · Cited by 245
A comprehensive review on microchannel heat sinks for electronics cooling
Yu, Z.-B., Li, M.-T., & Cao, B.-Y. (2023) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad12d4 · Cited by 286
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218
Review of energy efficiency and system performance of residential heat pump water heaters
Willem, H., Lin, Y., & Lekov, A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.023 · Cited by 199
Wang, H., Peterson, R., Harada, K. J., Miller, E., Ingram-Goble, R., Fisher, L., Yih, J., & Ward, C. (2010) · Energy · doi:10.1016/j.energy.2010.10.020 · Cited by 181
Icephobic Strategies and Materials with Superwettability: Design Principles and Mechanism
Jamil, M. I., Ali, A., Haq, F., Zhang, Q., Zhan, X., & Chen, F. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b03276 · Cited by 153
Tang, J., Gong, G., Su, H., Wu, F., & Herman, Č. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.02.042 · Cited by 122
Wang, F., Wang, Z., Zheng, Y., Lin, Z., Hao, P., Huan, C., & Wang, T. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.11.018 · Cited by 118
Tuo, H., & Hrnjak, P. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.06.002 · Cited by 99
Liquid infused surfaces with anti-icing properties
Wang, G., & Guo, Z. (2019) · Nanoscale · doi:10.1039/c9nr06934h · Cited by 91
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86
Chung, Y., Yoo, J. W., Kim, G. T., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.10.085 · Cited by 81
Determination method of defrosting start-time based on temperature measurements
Kim, M.-H., & Lee, K.-S. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.02.071 · Cited by 79
Xu, B., Han, Q., Chen, J., Li, F., Wang, N., Li, D., & Pan, X. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.09.026 · Cited by 71
Kosmadakis, G. M., Landelle, A., Lazova, M., Manolakos, D., Kaya, A., Huisseune, H., Karavas, C.-S. G., Tauveron, N., Revellin, R., Haberschill, P., et al. (2016) · Energy · doi:10.1016/j.energy.2016.10.047 · Cited by 68
Xiong, T., Liu, G., Huang, S., Yan, G. F., & Yu, J. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117820 · Cited by 66
Byrne, P., Miriel, J., & Lénat, Y. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.03.002 · Cited by 63
A frost-free dedicated outdoor air system with exhaust air heat recovery
Zhang, Z., Zhang, C., Ge, M.-C., & Yu, Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.09.091 · Cited by 63
Self-citationPotential use of smart coatings for icephobic applications: A review
Shamshiri, M., Jafari, R., & Momen, G. (2021) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2021.127656 · Cited by 61
Wang, Y., Zong, S., Song, Y., Cao, F., He, Y., & Gao, Q. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117606 · Cited by 60
A study on thermohydraulic characteristics of fluid flow through microchannels
Sharma, J. P., Sharma, A., Jilte, R. D., Kumar, R., & Ahmadi, M. H. (2019) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-019-08741-4 · Cited by 56
Barbosa, J. R., Jr., Melo, C., Hermes, C. J. L., & Waltrich, P. J. (2009) · Applied Energy · doi:10.1016/j.apenergy.2008.11.027 · Cited by 57
Huang, W., Zhang, T., Ji, J., & Xu, N. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.12.033 · Cited by 54
Experimental investigation of frost formation on a parallel flow evaporator
Wu, J., Ouyang, G., Hou, P., & Xiao, H. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.11.006 · Cited by 53
Slippery Photothermal Trap for Outstanding Deicing Surfaces
Jamil, M. I., Wang, Q., Ali, A., Hussain, M. A., Aziz, T., Zhan, X., & Zhang, Q. (2021) · Journal of Bionic Engineering · doi:10.1007/s42235-021-0046-7 · Cited by 53
Desiccant coated heat exchanger and its applications
Zhao, L., Wang, R. Z., & Ge, T. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.06.008 · Cited by 54
Konrad, M. E., & MacDonald, B. D. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113739 · Cited by 52
Heat and mass transfer comparisons of desiccant coated microchannel and fin-and-tube heat exchangers
Sun, X., Dai, Y., Ge, T., Zhao, Y., & Wang, R. Z. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.01.071 · Cited by 50
Performance comparison of air-source heat pump water heater with different expansion devices
Peng, J.-W., Li, H., & Zhang, C. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.01.113 · Cited by 49
Self-citationHuang, W., Ji, J., Xu, N., & Li, G. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.03.048 · Cited by 49
Liu, X., Yu, J., & Yan, G. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114634 · Cited by 47
Lazova, M., Huisseune, H., Kaya, A., Lecompte, S., Kosmadakis, G. M., & Paepe, M. D. (2016) · Energies · doi:10.3390/en9060432 · Cited by 44
Review on frosting, defrosting and frost management techniques in industrial food freezers
Badri, D., Toublanc, C., Rouaud, O., & Michel Havet, C. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111545 · Cited by 45
Li, K., Xia, D., Luo, S., Zhao, Y., Tu, R., Zhou, X., Zhang, H., & Su, L. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117766 · Cited by 40
Process simulation and analysis of a closed-loop heat pump clothes dryer
Cao, X. S., Zhang, J., Li, Z., Shao, L.-L., & Zhang, C. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117545 · Cited by 40
Self-citationMeng, J., Liu, M., Zhang, W., Cao, R., Li, Y., Zhang, H., Gu, X., Du, Y. C., & Geng, Y. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.02.007 · Cited by 39
A new method of defrosting evaporator coils
Mader, G., & Thybo, C. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.01.033 · Cited by 37
Ko, Y. M., Song, J. Y., Lee, J. W., Sohn, S., Song, C. H., Khoshvaght-Aliabadi, M., Kim, Y., & Kang, Y. T. (2023) · Energy · doi:10.1016/j.energy.2023.129609 · Cited by 43
Xiong, T., Ying, Y., Han, B., Yan, G., & Yu, J. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.09.003 · Cited by 35
Chen, S.-L., Chen, K., Zhu, X., Jin, X.-Q., & Du, Z.-M. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.119702 · Cited by 31
Performance enhancement of a thermally activated cooling system using microchannel heat exchangers
Wang, H., & Peterson, R. B. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.05.026 · Cited by 31
Kong, X.-Q., Li, J.-Y., Wang, B., & Li, Y. (2020) · Solar Energy · doi:10.1016/j.solener.2019.11.104 · Cited by 29
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29
Yoo, J., Chung, Y., Kim, G. T., Song, C.-W., Yoon, P., Sa, Y., & Kim, M. S. (2018) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2018.08.014 · Cited by 22
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26
Achieving deep dehumidification through a heat pump-boosted desiccant wheel system
Cheng, J., Wang, Z., Cao, X. S., Li, X., & Zhang, C. (2024) · Energy Conversion and Management · doi:10.1016/j.enconman.2024.118604 · Cited by 26
Self-citationA Study on Electric Vehicle Heat Pump Systems in Cold Climates
Zhang, Z., Li, W., Shi, J., & Chen, J. (2016) · Energies · doi:10.3390/en9110881 · Cited by 26
Qiao, H., Aute, V., & Radermacher, R. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.08.020 · Cited by 25
Zhang, Z., Cao, X. S., Yang, Z., Shao, L.-L., & Zhang, C. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.080 · Cited by 24
Self-citationFlat tube heat exchangers: Experimental analysis of frosting and water retention
Westhaeuser, J., Brauchle, L., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119319 · Cited by 24
Li, F., Shi, K., Sun, X., Yue, B., Huang, D., Zhao, R., & Zhao, Y. (2024) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2024.03.011 · Cited by 22
Ma, D., Chen, Q., & Yan, G. F. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123359 · Cited by 22
Li, K., Xia, D., Bao, J., Luo, S., Zhang, H., Liu, N., Su, L., & Sheng, L. (2021) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2021.101281 · Cited by 22
Experimental investigation of Al–Cu composed tube–fin heat exchangers for air conditioner
Wang, S., Cheng, S., Yu, H., Rao, Z., & Liu, Z. (2013) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2013.08.007 · Cited by 22
Experimental analysis of an air–water heat pump with micro-channel heat exchanger
Brignoli, R., Cecchinato, L., & Zilio, C. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.08.027 · Cited by 21
Physics-informed deep residual neural network for finned-tube evaporator performance prediction
Liang, X.-Y., Zhang, B., & Zhang, C. (2024) · Energy · doi:10.1016/j.energy.2024.131822 · Cited by 22
Self-citationSustainable anti-frosting surface for efficient thermal transport
Wen, R.-F., Ying, Y., Ma, X.-H., & Yang, R. (2022) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2022.100937 · Cited by 24
Tian, Z., Ma, L., Gu, B. Q., Yang, L., & Liu, F. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.10.032 · Cited by 21
Self-citationApproaching optimum COP by refrigerant charge management in transcritical CO2 heat pump water heater
He, Y.-J., Liang, X., Cheng, J., Shao, L.-L., & Zhang, C. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.06.011 · Cited by 21
Self-citationQu, X., Shi, J., Qi, Z., & Chen, J. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.04.051 · Cited by 20
Analysis of cyclic frosting and defrosting of a vehicle heat pump
Westhaeuser, J., Schatz, H., Albrecht, J.-C., Tegethoff, W. J., Lemke, N., & Koehler, J. (2023) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2023.05.011 · Cited by 18
A novel defrosting method in gasoline vapor recovery application
Liang, J., Sun, L. M., & Li, T. (2018) · Energy · doi:10.1016/j.energy.2018.08.172 · Cited by 18
Saadatfar, B., Fakhrai, R., & Fransson, T. (2013) · Cited by 17
Yang, X., Liu, X., Dong, X.-J., Meng, Y., Hou, Y., & Lai, T.-W. (2022) · Energy Storage and Saving · doi:10.1016/j.enss.2022.05.001 · Cited by 16
Zhu, J., Sun, H., Liu, X.-H., Sun, Z.-L., & Lei, Z. (2022) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2022.06.031 · Cited by 15
Cheng, J., Cao, X. S., Shao, L.-L., & Zhang, C. (2023) · Energy · doi:10.1016/j.energy.2023.127989 · Cited by 16
Self-citationDesign and analysis of a novel dual source vapor injection heat pump using exhaust and ambient air
Li, J., Fan, Y., Zhao, X., Bai, X., Zhou, J., Badiei, A., Myers, S., & Ma, X. (2020) · Energy and Built Environment · doi:10.1016/j.enbenv.2020.11.004 · Cited by 16
Xing, H., Fan, W., Qu, M.-L., Chen, J.-B., & Chen, Q.-H. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.03.011 · Cited by 14
Sun, H., Zhu, J., Liu, X.-H., Sun, Z., & Lei, Z. (2022) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2022.03.023 · Cited by 13
Superhydrophobic Microchannel Heat Exchanger for Electric Vehicle Heat Pump Performance Enhancement
Sui, Y., Sui, Z., Liang, G., & Wu, W. (2023) · Sustainability · doi:10.3390/su151813998 · Cited by 14
Experimental Study on Frost Height of Round Plate Fin-Tube Heat Exchangers for Mobile Heat Pumps
Lee, M., Kim, Y., & Lee, D.-Y. (2012) · Energies · doi:10.3390/en5093479 · Cited by 15
Li, K., Luo, S., Yu, J., Tang, Q., Su, L., & Fang, Y. (2020) · International Journal of Energy Research · doi:10.1002/er.5519 · Cited by 13
“Shao et al10 compared the performance of traditional finned-tube heat exchanger with microchannel heat exchanger numerically and experimentally.”
BackgroundLyu, W., Xu, Z., Xu, Y., Wang, Z., Jiang, C., Li, X., Li, J., & Gou, X. (2025) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2025.07.025 · Cited by 12
Luo, B., Li, F., Wu, S., Shi, K., Ding, Y., Zhao, R., Huang, D., & Shi, W. (2025) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2025.01.030 · Cited by 11
Liu, X., Chen, H., Wang, X., & Kefayati, G. (2020) · Energies · doi:10.3390/en13051065 · Cited by 11
Jagirdar, M., & Lee, P. S. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.12.111 · Cited by 10
Toward Anti-icing and De-icing Surfaces: Effects of Surface Topography and Temperature
Heydari, G. (2016) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 10
Yousaf, S., Bradshaw, C. R., Kamalapurkar, R., & San, O. (2025) · Science and Technology for the Built Environment · doi:10.1080/23744731.2025.2460374 · Cited by 9
A multi-mode packaged dedicated outdoor air system embedded with a four-coil heat pump
Cheng, J., Cao, X. S., Shao, L.-L., & Zhang, C. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113222 · Cited by 9
Self-citationSpontaneous Formation of a Sustainable Antifreeze Coating by Peptide Self-Assembly
Kaganovich, M., Gibeon, E., Bakalinsky, A. S., Shalev, D. E., Braslavsky, I., & Reches, M. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c22816 · Cited by 8
A prediction model of air-source heat pump system performance with frost-retarded heater
Wu, S., Sun, Y. J., Wang, F., Ma, Z., Zhao, R., & Huang, D. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123315 · Cited by 8
Xiong, T., Liu, G., & Yan, G. (2023) · Applied Sciences · doi:10.3390/app13116378 · Cited by 7
James, A., Raj, A. K., Srinivas, M., Mohanraj, M. P., & Jayaraj, S. (2023) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2023.101720 · Cited by 5
Wang, S., Cheng, J.-H., & Zhang, C. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116052 · Cited by 4
Self-citationConsistent control strategy for CO2 refrigeration systems based on refrigerant charge management
He, Y.-J., Tai, Y.-D., Zhao, X., & Zhang, C. (2022) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2022.09.009 · Cited by 4
Self-citationFeng, Y., Zhang, W., Zhang, Z., Shao, X., Liu, P., & Wang, X. (2022) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-022-11774-x · Cited by 4
Moghadam, S. G., Momen, G., & Jafari, R. (2025) · Journal of Ionic Liquids · doi:10.1016/j.jil.2025.100139 · Cited by 3
Chen, Y., Song, Y., Xie, H., Yang, M., Cao, F., Pang, X., Bai, G., Wang, X., & Wang, X. (2026) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2026.130795 · Cited by 3
Zhang, Z., Chen, M., Zhang, W., & Wang, X. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101827 · Cited by 3
Pisano, A. (2017) · doi:10.4995/thesis/10251/86182 · Cited by 3
Advancements in dynamic simulation techniques for refrigeration cycles: A comprehensive review
Murthy, A. A., Praveen Shenoy, K., Krishan, G., Patil, I. S., Gangadharan, K. V., & Cholleti, E. R. (2024) · Energy 360. · doi:10.1016/j.energ.2024.100007 · Cited by 2
Zheng, H., Jiang, S., Wang, F., & Wang, X. (2024) · 2024 7th International Conference on Computer Information Science and Application Technology (CISAT) · doi:10.1109/cisat62382.2024.10695276
Wang, S., Ke, H., Li, X., & Cheng, S. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.12.010 · Cited by 2
Safikhani, H., & Shabani, H. (2020) · International Journal of Engineering · doi:10.5829/ije.2020.33.12c.17 · Cited by 2
NUMERICAL MODEL FOR MICROCHANNEL CONDENSERS AND GAS COOLERS WITH AN IMPROVED AIR-SIDE APPROACH
Ballester, S. M. (2012) · doi:10.4995/thesis/10251/17453 · Cited by 2
Economic analysis of air-water heat pump technologies with a screening method
Mader, G. (2015) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Leoni, A. (2017) · theses.fr (ABES) · doi:10.70675/f052b4afz1f26z4ed9zbeaez6d56015b3f69 · Cited by 2
Wang, Y., Zheng, W., Wu, W., Jiang, Y., & Sun, C. (2025) · Energy · doi:10.1016/j.energy.2025.138423 · Cited by 1
Lee, M. (2012) · Advances in Mechanical Engineering · doi:10.1155/2012/863731 · Cited by 1
Calabrese, N., Mastrullo, R. M. A., & Mauro, A. W. (2012) · ENEA Open Archive (National Agency for New Technologies, Energy and Sustainable Economic Development)
Metadata
- Authors
- Shao, L.-L., Yang, L., & Zhang, C.-L.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Zhang, Chun-Lu
- ORCID
- Zhang, Chun-Lu
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2010-04
- Volume
- 87
- Issue
- 4
- Pages
- 1187-1197
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2157064791
- Cited by
- 112
- References
- 32
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 9 · 2023: 9 · 2022: 10 · 2021: 11 · 2020: 6 · 2019: 7 · 2018: 5 · 2017: 7 · 2016: 9 · 2015: 4 · 2014: 4 · 2013: 3 · 2012: 8
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- heat pumps, microchannel heat exchangers, finned tube heat exchanger, evaporator performance, fan speed, fin density, refrigerant charge reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›