A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit

Yao, Yang, Jiang, Yiqiang, Deng, Shiming, Ma, Zuiliang·2004·International Journal of Heat and Mass Transfer

Integrity signals

Registry

Crossref · 10.1016/j.ijheatmasstransfer.2004.03.013

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Previously reported frosting models [14-18] describe heat and mass transfer in detail but all neglect changes in airflow that result from formation of frost.

    “These previously reported frosting models [14-18] describe the heat and mass transfer in detail; however, they all neglect the changes in airflow that result from the formation of frost.”
  • Analytical studies for the thermal performance of a heat exchanger dealt with frost formation phenomena too simplistically by either proposing models without robust validations or using correlations for heat transfer coefficients derived for a specific heat exchanger experimentally.

    “However, analytical studies for the thermal performance of a heat exchanger [20-23] dealt with the frost formation phenomena too simplistically by either proposing models without robust validations or using correlations for heat transfer coefficients that were derived for a specific heat exchanger experimentally.”
  • There are few analytic studies for frosting behavior of real heat exchangers.

    “As a result, there are few analytic studies for frosting behavior of real heat exchangers [21-25].”
  • Harmful frosting phenomena mainly occur in various industry processes under ordinary low-temperature conditions; most theoretical and experimental research on frost deposition has focused on ordinary low-temperature conditions.

    “Harmful frosting phenomena mainly occur in various industry processes that occur under ordinary low-temperature conditions; hence, most theoretical and experimental research works on frost deposition have been focused on ordinary low-temperature conditions [21,22].”
  • At constant air temperature, the probability of frost formation increased with increasing humidity ratio.

    “The authors concluded that at a constant air temperature, the probability of frost formation increased with increasing humidity ratio”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yao, Y., Jiang, Y., Deng, S., & Ma, Z.
Affiliations
  • Harbin Institute of Technology (CN)
  • Hong Kong Polytechnic University (HK)
Corresponding author
Deng, Shiming
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2004-08
Volume
47
Issue
17-18
Pages
3745-3756
ISSN
0017-9310 (ISSN-L)
OpenAlex
W1975432369
Cited by
196
References
6
Citations by year
2026: 10 · 2025: 9 · 2024: 18 · 2023: 12 · 2022: 10 · 2021: 15 · 2020: 13 · 2019: 14 · 2018: 10 · 2017: 13 · 2016: 11 · 2015: 11 · 2014: 7 · 2013: 5 · 2012: 5
FWCI
9.75
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Heat and Mass Transfer (publishedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
Funders
  • National Science Foundation
  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
frost formation, operational reliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review