CoChat

Predictive air-conditioner control for electric buses with passenger amount variation forecast☆

He, Hongwen, Yan, Mei, Sun, Chao, Peng, Jiankun, Li, Menglin, Jia, Hui · 2018 · Applied Energy
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Abstract Air-conditioners (AC) usually consume the most electricity among all of the auxiliary components in an electric bus, over 30% of the battery power at maximum. On-board passengers carried by the electric bus are important but random heat sources, which are obsessional disturbances for the cabin temperature control and energy management of the AC system. This paper aims to improve the AC energy efficiency via passenger amount variation analysis and forecast in a model predictive control (MPC) framework. Three forecasting approaches are proposed to realize the passenger amount variation prediction in real-time, namely, stochastic prediction based on Monte Carlo, radial basis function neural network (RBF-NN) prediction, and Markov-chain prediction. A sample passenger number database along a typical bus line in Beijing is built for passenger variation pattern analysis and forecast. A comparative study of the above three prediction approaches with different prediction lengths (bus stops in this case) is conducted, from both the energy consumption and temperature control perspectives. A predictive AC controller is developed, and evaluated by comparing with Dynamic Programming (DP) and a commonly used rule-based control strategy. Simulation results show that all the three forecasting methods integrated within the MPC framework are able to achieve more stable temperature performance. The energy consumptions of MPC with Markov-chain prediction, RBF-NN forecast and Monte Carlo prediction are 6.01%, 5.88% and 5.81% lower than rule-based control, respectively, on the Beijing bus route studied in this paper.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2017.08.181

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 80

Metadata

Authors
He, H., Yan, M., Sun, C., Peng, J., Li, M., & Jia, H.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2018-10
Volume
227
Pages
249-261
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2751379472
Cited by
80
References
2
FWCI
4.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictive air-conditioner control for electric buses with passenger amount variation forecast☆. https://app.cochat.ai/papers/10.1016/j.apenergy.2017.08.181
The paper
He, H., Yan, M., Sun, C., Peng, J., Li, M., & Jia, H. (2018). Predictive air-conditioner control for electric buses with passenger amount variation forecast☆. Applied Energy. https://doi.org/10.1016/j.apenergy.2017.08.181

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.