A review of power consumption models of servers in data centers
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study provides an overview of power consumption models of servers in data centers. The server is the basic unit of both power and heat flow paths; therefore, its power consumption model can be used for both energy management and thermal management. Investigations of server power trends were carried out according to the data from the Standard Performance Evaluation Corporation (SPEC). It is found that a heavier workload can be handled without consuming more energy, and the difference between the peak power and idle power of the servers is not consistent from generation to generation. Furthermore, the existing power consumption models are categorized as additive models, baseline power + active power (BA) models, and other models based on calculation formula and other factors. Specifically, there are four forms of BA models: linear regression models, power function models, non-linear models and polynomial models. Besides, these models have been compared in terms of accuracy. It can be found that the polynomial model and the linear regression model perform better in terms of accuracy. Additionally, the model applications are summarized. Considering server architecture upgrades and technological innovation, the establishment of the new model and its application scenarios are discussed. Moreover, in-depth and accurate power consumption models must be extensively researched and applied to effectively improve data centers, including information technology (IT) equipment and cooling equipment, in terms of overall energy performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
United States Data Center Energy Usage Report
Lawrence Berkeley National Laboratory (LBNL), B., Shehabi, A., USDOE, Smith, S., Sartor, D., Brown, R., Herrlin, M., Koomey, J., Masanet, E., Horner, N., et al. (2016) · doi:10.2172/1372902 · Cited by 1,040
A Taxonomy and Survey of Energy-Efficient Data Centers and Cloud Computing Systems
Beloglazov, A., Buyya, R., Lee, Y. C., & Zomaya, A. (2011) · Advances in Computers · doi:10.1016/b978-0-12-385512-1.00003-7 · Cited by 777
Statistical modeling of power/energy of scientific kernels on a multi-GPU system
Ghosh, S., Chandrasekaran, S., & Chapman, B. (2013) · 2013 International Green Computing Conference Proceedings · doi:10.1109/igcc.2013.6604488 · Cited by 10
Cited by
Zhu, H., Zhang, D., Goh, H. H., Wang, S., Ahmad, T., Mao, D., Liu, T., Zhao, H., & Wu, T. (2023) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.104322 · Cited by 164
Water-energy tradeoffs in data centers: A case study in hot-arid climates
Karimi, L., Yacuel, L., Johnson, J. D., Ashby, J., Green, M., Renner, M., Bergman, A., Norwood, R., & Hickenbottom, K. L. (2022) · Resources Conservation and Recycling · doi:10.1016/j.resconrec.2022.106194 · Cited by 43
Parsafar, P. (2025) · The Journal of Supercomputing · doi:10.1007/s11227-024-06510-1 · Cited by 9
Słoniec, J., Kulisz, M., Małecka-Dobrogowska, M., Konurbayeva, Z., & Sobaszek, Ł. (2025) · Energies · doi:10.3390/en18215573 · Cited by 9
Metadata
- Authors
- Jin, C., Bai, X., Yang, C., Mao, W., & Xu, X.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 265
- Pages
- 114806
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3015015599
- Cited by
- 229
- References
- 3
- FWCI
- 20.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of power consumption models of servers in data centers. https://app.cochat.ai/papers/10.1016/j.apenergy.2020.114806
- The paper
- Jin, C., Bai, X., Yang, C., Mao, W., & Xu, X. (2020). A review of power consumption models of servers in data centers. Applied Energy. https://doi.org/10.1016/j.apenergy.2020.114806
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.