The DOI matches its Crossref record; 14 of the 17 references it cites were found in a registry or an index.
Experimental study on frost growth and dynamic performance of air source heat pump system
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This frost then deteriorates the system performances (Barrow, 1985; Guo et al., 2008; Sanders, 1974).”
From Modeling of a fan-supplied flat-tube heat exchanger exposed to non-uniform frost growth (2017) · cites this paper as Guo et al., 2008
In the citing paper
“This may result from the fact that the frost layer is always uneven during the entire frosting process, regardless of the types of plate surfaces, as seen in Fig. 13 (a) [115], (b) [117], (c) [116], and (d) [106].”
From Review on the measurement and calculation of frost characteristics (2018) · cites this paper as [117]
In the citing paper
“The frosting process on a cold surface is consisted of three stages: crystal growth, frost layer growth and frost layer full growth.”
In the citing paper
“The growth rate of frost thickness, the heating capacity and COP of the heat pump increased as the frosting time elapsed until the column-type frost layer is generated.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Guo et al. [37]
In the citing paper
“For constant outdoor temperature, the duration of first and third stage of growth formation are similar for relative humidity ranging from 65% to 85%.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Guo et al. [37]
In the citing paper
“The duration of second stage decreased with increase of relative humidity.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Guo et al. [37]
In the citing paper
“Therefore, heating capacity and COP are slightly reduced.”
In the citing paper
“In last stage, due to increased rate of frost layer formation, the air flow rate decreases and thermal resistance increases affecting heating capacity and COP negatively.”
In the citing paper
“In initial stage of frost formation heating capacity of ASHP unit increased.”
In the citing paper
“In the second stage, frost layer increases, which reduces the evaporating pressure and airflow rate marginally.”
In the citing paper
“However, the pressure drop is relatively less.”
Citations
Cites
Yao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 152
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
Performance of finned tube heat exchangers operating under frosting conditions
Yan, W.-M., Li, H.-Y., Wu, Y.-J., Lin, J.-Y., & Chang, W.-R. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00346-0 · Cited by 95
Modeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94 · cited 2×
“In most of these experimental [1–4,7] and numerical [5,6] studies the air flow rate”
BackgroundResultLocal variation of frost layer thickness and morphology
Qu, K., Komori, S., & Jiang, Y. (2006) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2005.05.004 · Cited by 67
Effect of frost growth on the performance of louvered finned tube heat exchangers
Kondepudi, S. N., & O'Neal, D. L. (1989) · International Journal of Refrigeration · doi:10.1016/0140-7007(89)90030-3 · Cited by 67
Fan supplied heat exchanger fin performance under frosting conditions
Chen, H., Thomas, L., & Besant, R. W. (2003) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00011-7 · Cited by 59
Seker, D., Karatas, H., & Egrican, P. D. N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.004 · Cited by 56
Tso, C. P., Cheng, Y. C., & Lai, A. C. K. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.09.018 · Cited by 33
Flagged first, then by citations
3 of the 17 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- Senshu, 1990, Heat pump performance under frosting conditions: Part I – Heat and mass transfer on cross-finned tube heat exchangers under frosting conditions, ASHRAE Trans., 96, 324
- Yasuda, 1990, Heat pump performance under frosting conditions: Part II – Simulation of heat pump cycle characteristics under frosting conditions, ASHRAE Trans., 96, 330
- Miller, 1987, Laboratory examination and seasonal analysis of frosting and defrosting for an air-to-air heat pump, ASHRAE Trans., 93, 1474
- Guo, 2006, Numerical simulation and experimental verification on dynamic performance of air source heat pump under frosting conditions, J. Xi’an Jiaotong Univ., 40, 544
Cited by
Sorted by citations
Items 101–173 of 173
Li, Y., Li, M.-X., Utaka, Y., Daitoku, T., Ohkubo, H., & Yang, C.-J. (2019) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2019.03.014 · Cited by 11
A review of heat pump research in China using bibliometric methods
Zhou, C., Ye, S., Ni, L., & Yao, Y. (2022) · Journal of Renewable and Sustainable Energy · doi:10.1063/5.0075868 · Cited by 12
Investigation on the influence of EEV opening on the reliability of an R290 ASHP during defrosting
Du, Y.-J., Wu, J., Wang, C., Chen, R., & Li, J.-B. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110218 · Cited by 12
Qu, M., Deng, S., & JIANG, Y. (2010) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132510000332 · Cited by 12
Vapor pressure above concentrated aqueous solution of lithium bromide at subzero temperatures
Ren, H., Chen, G., Luo, J., & Zhang, S. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.03.003 · Cited by 12
Di, Y., Zhao, C., Lian, X., Li, X., Bao, D., & Liu, J. (2023) · Buildings · doi:10.3390/buildings13082107 · Cited by 10
Citarella, B., Viscito, L., Mochizuki, K., & Mauro, A. W. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118796 · Cited by 9
Ghaddar, D., Boyina, K., Chettiar, K., Hoque, M. J., Baker, M., Bhalerao, P., Reagen, S., & Miljković, N. (2023) · Applied Physics Letters · doi:10.1063/5.0157647 · Cited by 10
Liu, J.-D., Wang, W., Sun, Y.-Y., & Deng, S. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2018.01.013 · Cited by 10
Self-citationPu, J., Shen, C., Yang, H.-T., & Wen, M. (2021) · Energy for Sustainable Development · doi:10.1016/j.esd.2021.10.007 · Cited by 8
Jin, Z., Zheng, Y., Huang, D., Zhang, Y., Lv, S., & Sun, H. (2023) · Sustainable Cities and Society · doi:10.1016/j.scs.2023.104942 · Cited by 9
Huang, W., Ji, J., Modjinou, M., & Qin, J. Y. (2017) · International Journal of Photoenergy · doi:10.1155/2017/3082740 · Cited by 9
Tang, J., Herman, Č., & Gong, G. (2020) · Applied Mathematical Modelling · doi:10.1016/j.apm.2020.02.027 · Cited by 8
Investigation on thermal-hydraulic performance of outdoor heat exchanger in air sources heat pump
Fang, Z., Li, L., Cheng, Y. C., Wang, P., & Oladokun, M. O. (2017) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2017.01.008 · Cited by 7
The modelling of reverse defrosting cycles of air-to-water heat pumps with TRNSYS
Dongellini, M., Piazzi, A., Biagi, F., & Morini, G. L. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201911101063 · Cited by 7
Nordsyn study on air-to-water heat pumps in humid Nordic climate
Stignor, C. H., & Walfridson, T. (2019) · TemaNord · doi:10.6027/tn2019-502 · Cited by 7
Experimental study on defrosting multi outdoor units in turn for air source heat pump using hot gas
Li, X., Ma, G.-Y., Lu, T., Gao, L., Rong, W.-L., Gong, Y.-X., & Xu, S.-X. (2025) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2025.03.007 · Cited by 6
Experimental study about frost formation and growth in the evaporator of an air-to-water heat pump
Gallén, D. A., Marchante-Avellaneda, J., Hassan, A. H., & Navarro-Peris, E. (2025) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2025.08.013 · Cited by 5
Zheng, J.-W., Xie, Y.-S., Wu, Y.-L., Yang, K.-S., & Wang, C.-C. (2024) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2024.125544 · Cited by 5
James, A., Raj, A. K., Srinivas, M., Mohanraj, M. P., & Jayaraj, S. (2023) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2023.101720 · Cited by 5
Sun, Y. J., Zhao, R., Wu, S., & Huang, D. (2021) · Energies · doi:10.3390/en14196069 · Cited by 5
Wang, Y., Wang, L., Huang, Q., & Cui, Y. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.12.129 · Cited by 5
ANFIS model for prediction of the frost accumulation on surfaces of finned-tube heat exchanger
Zhu, R., Liu, M., Wang, G., Wang, Q., Wu, W., Li, G., & Wang, H. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.128388 · Cited by 6
Zhang, X., Chen, X., Zhang, G., Yang, Y., & Ni, L. (2026) · Energy · doi:10.1016/j.energy.2026.140524 · Cited by 4
Ikeda, H., Ooi, Y., & Nakaya, T. (2021) · Energies · doi:10.3390/en14217034 · Cited by 4
Aidoun, Z., Ouzzane, M., & Bendaou, A. (2011) · InTech eBooks · doi:10.5772/19483 · Cited by 4
Development and validation of innovative hot water spray defrosting method
Bahar, E. M., Aktaş, M., Aktekeli, B., Şevik, S., Güven, Y., & Aktaş, A. (2025) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2025.103668 · Cited by 3
Transient Exergy Analysis of the Condenser and Evaporator of an Air Source Heat Pump Water Heater
Öztürk, M. M., & Erbay, L. B. (2016) · Journal of Mechanics Engineering and Automation · doi:10.17265/2159-5275/2016.07.004 · Cited by 3
A sustainable defrosting technology for air source heat pump systems
Zhang, L., Wu, L., Jiang, J., Song, M., Zhang, X., Shao, K., Han, S., & Jiang, Y. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-15495-9.00010-1 · Cited by 2
Zhu, L., Chen, M., Zhang, X., & Huang, S. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.114650 · Cited by 2
Micro-CT investigation of urea crystal structures for frost analysis
Labuschagne, A. A., Zhu, T., & Rohlfs, W. (2025) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2025.109893 · Cited by 2
Frost-EffNet: A deep learning model for frost detection in refrigeration systems
Mehmood, M. U., Rahman, H. U., Desdemir, D. B., & Lazoğlu, İ. (2025) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2025.09.029 · Cited by 2
Tahavvor, A., & Hosseini, S. (2015) · Iranian Journal of Science and Technology Transactions of Mechanical Engineering · doi:10.22099/ijstm.2015.2999 · Cited by 4
Wang, S., Ke, H., Li, X., & Cheng, S. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.12.010 · Cited by 2
Frost Measuring and Prediction Systems for Demand Defrost Control
de Aguiar, M. L., Gaspar, P., & da Silva, P. D. (2019) · Novel Technologies and Systems for Food Preservation · doi:10.4018/978-1-5225-7894-9.ch002 · Cited by 3
Frost Measurement Sensors for Demand Defrost Control Systems: Purposed Applications in Evaporators
de Aguiar, M. L., Gaspar, P., & da Silva, P. D. (2019) · Transactions on Engineering Technologies · doi:10.1007/978-981-32-9531-5_12
Research Progress on Defrosting Strategy of Heat Pump System Heat Exchanger Outside for EV
Ji, H., Guo, F., Wang, Y., & Luo, X. (2019) · World Conference on Mechanical Engineering and Intelligent Manufacturing (WCMEIM) · doi:10.1109/wcmeim48965.2019.00092 · Cited by 2
Nordsyn study on air-to-air heat pumps in humid Nordic climate
Stignor, C. H., & Walfridson, T. (2019) · TemaNord · doi:10.6027/tn2019-504 · Cited by 2
Research on frosting detection method of air source Heat pump based on vision Technology
Yuan, K., Chen, J., Liu, Y., & Lao, J. (2022) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2354/1/012017 · Cited by 2
Experimental Study and Analysis of the Desublimation of CO2
Oyinloye, M. A., Gubba, S. R., & Roberts, W. L. (2023) · Proceeding of Second Thermal and Fluids Engineering Conference · doi:10.1615/tfec2023.cry.046035 · Cited by 2
Economic analysis of air-water heat pump technologies with a screening method
Mader, G. (2015) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Leoni, A. (2017) · theses.fr (ABES) · doi:10.70675/f052b4afz1f26z4ed9zbeaez6d56015b3f69 · Cited by 2
Wang, S.-Q., Wei, W.-Z., Luo, J., Wang, W., Sun, Y.-Y., Li, Z.-Y., Zhu, W., & Deng, S. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116558 · Cited by 1
Self-citationJiankai, D., Qu, M., Yiqiang, J., Yang, Y., Deng, S., & Honglei, W. (2011) · International Conference on Computer Distributed Control and Intelligent Environmental Monitoring · doi:10.1109/cdciem.2011.175 · Cited by 1
Experimental study of heating transfer characteristic in the cross-flow packing tower
Wen, X., Liang, C., Zhang, X., & Zhou, X. (2011) · International Conference on Electric Technology and Civil Engineering · doi:10.1109/icetce.2011.5775355 · Cited by 1
A New Dynamic Heat Exchanger Model with Frosting and Defrosting
Qiao, H., Aute, V., & Radermacher, R. (2014) · Purdue e-Pubs (Purdue University System) · Cited by 1
An Experimental Analysis of Air Source Heat Pump Water Heater
Öztürk, M., & Erbay, L. B. (2012) · DergiPark (Istanbul University) · Cited by 1
Zhu, J., & Elbel, S. W. (2018) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2018-01-1193 · Cited by 1
EXPERIMENTAL ANALYSIS OF THE AIR DEFROST PROCESS IN AN INDUSTRIAL COOLING SYSTEM
Erten, S., Koşan, M., Işgen, F., & Aktaş, M. (2020) · DergiPark (Istanbul University) · Cited by 1
Rapid Identification of Economic Indicators of Integrated Energy Systems Based on Data Analysis
He, W. Z., Lu, H., Liu, Y., Chen, G., & Huang, Z. (2022) · Mathematical Problems in Engineering · doi:10.1155/2022/9180774 · Cited by 1
The role of condensation from humid air on melting of ice
Chandramohan, A., Weibel, J. A., & Garimella, S. V. (2016) · I-THERM :/I-THERM - Intersociety Conference on Thermal Phenomena in Electronic Systems · doi:10.1109/itherm.2016.7517704
THE ENERGETIC ANALYSIS OF AIR SOURCE HEAT PUMP`S DEFROSTING SYSTEMS.
Złoczowska, E. (2017) · International Multidisciplinary Scientific GeoConference SGEM ... · doi:10.5593/sgem2017/42/s17.072
Development of an evaluation method on using electric heating in cold rural areas of ChinaPreprint
Yu, W. B., Zhou, H., Huang, J., Yu, Z., Wei, S., Wu, X., & Ma, X. (2022) · Research Square · doi:10.21203/rs.3.rs-1655463/v1
Study on Regional Suitability of Heat-Source Tower Heat Pump
Guo, Y., Cao, X., Tong, G., Yu, P., Huang, S., & Wen, X. (2022) · Advances in transdisciplinary engineering · doi:10.3233/atde220305
A Feasibility study on using electric heating in cold rural areas of ChinaPreprint
Yu, W., Zhou, H., Huang, J., Yu, Z., Wei, S., Wu, X., & Ma, X. (2023) · Research Square · doi:10.21203/rs.3.rs-2280851/v1
Retrofit of a standard split-type air conditioner into an air-to-water heat pump
Botu, M., Marius, A., Ursescu, G. G., & Edward, R. (2023) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/1290/1/012005
Liu, X., Liu, Z., Zhan, W., Luo, C. X., Wang, H., & Zhou, M. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4867048
Measurement and calculation of frost characteristics on cold surfaces
Song, M., & Zhang, L. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95457-0.00006-x
Frosting on surface of nonhorizontal cold plate under natural convection in an ASHP unit
Song, M., & Zhang, L. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95457-0.00002-2
Yang, H., Liu, X., Liu, Z., Zhan, W., Luo, C. X., Wang, H., & Zhou, M. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.5036468
Micro-Ct Investigation of Urea Crystal Structures for Frost AnalysisPreprint
Labuschagne, A. A., Zhu, T., & Rohlfs, W. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.5051734
Wei, W., Guo, Y., Wang, W., Jiang, Z., Zhang, X., Dai, C., Sun, Y., Li, B., Wang, S., & Zhang, C. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5556478
Self-citationWei, W., Guo, Y., Jiang, Z., Zhang, X., Wang, W., Sun, Y., Wang, S., & Zhang, C. (2025) · Environmental science and engineering · doi:10.1007/978-981-95-3253-7_16
Self-citationNumerical study of frost formation on an industrial food freezing system
Badri, D. (2021) · theses.fr (ABES) · doi:10.70675/18ef7f42z85f6z4cf0z901dzac4832053863
Energy consumption in seafood freezing: An analysis on production capacity and freezer type
Stephen, M. S., Valsalan, S. A., & Ramanathan, H. N. (2026) · Next Energy · doi:10.1016/j.nxener.2026.100620
Anti-Frost Coatings Reduce Winter Emissions from Heat Pumps Without Compromising Comfort
Nawawi, S., Tuteja, A., & Vaishnav, P. (2026) · Environmental Science & Technology · doi:10.1021/acs.est.6c02800
Impact Dynamics and Heat Exchange of Cold Droplet on Supercooled Macrotextured Nonwettable Surfaces
Chowdhury, N. N., Yang, Y., & Shiri, S. (2026) · Langmuir · doi:10.1021/acs.langmuir.6c02398
Afghari, M. R., & Hashemi, M. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7036035
Wang, Z., Yang, Q., Li, H., Xu, C., Zhan, B., Zhang, Z., & Xu, Z. (2026) · Energy · doi:10.1016/j.energy.2026.141888
Choi, J., Kim, J., Roh, J., & Kim, Y. (2026) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2026.132460
Zhuang, L., Gao, H., Zheng, Z., Liu, J., & Wu, J. (2026) · Energy · doi:10.1016/j.energy.2026.142576
Zheng, J.-W., Zhang, Z., Wang, C.-K., Isaka, T., 佐々木, 実., Yang, K.-S., & Lo, C. (2026) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2026.129789
Metadata
- Authors
- Guo, X.-M., Chen, Y.-G., Wang, W.-H., & Chen, C.-Z.
- Affiliations
- Tianjin University of Commerce (CN)
- Corresponding author
- Guo, Xian-Min
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 28
- Issue
- 17-18
- Pages
- 2267-2278
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2133344973
- Cited by
- 173
- References
- 17
- Citations by year
- 2026: 11 · 2025: 11 · 2024: 14 · 2023: 17 · 2022: 17 · 2021: 15 · 2020: 14 · 2019: 13 · 2018: 8 · 2017: 10 · 2016: 15 · 2015: 6 · 2014: 5 · 2013: 2 · 2012: 3
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- Beijing Municipal Science and Technology Commission
- Tianjin Science and Technology Committee
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air-source heat pump, frost growth, frost thickness, frost accumulation, heating capacity, coefficient of performance, ice crystal growth, relative humidity, ambient temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review