The DOI matches its Crossref record; 14 of the 17 references it cites were found in a registry or an index.
Experimental study on frost growth and dynamic performance of air source heat pump system
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This frost then deteriorates the system performances (Barrow, 1985; Guo et al., 2008; Sanders, 1974).”
From Modeling of a fan-supplied flat-tube heat exchanger exposed to non-uniform frost growth (2017) · cites this paper as Guo et al., 2008
In the citing paper
“This may result from the fact that the frost layer is always uneven during the entire frosting process, regardless of the types of plate surfaces, as seen in Fig. 13 (a) [115], (b) [117], (c) [116], and (d) [106].”
From Review on the measurement and calculation of frost characteristics (2018) · cites this paper as [117]
In the citing paper
“The frosting process on a cold surface is consisted of three stages: crystal growth, frost layer growth and frost layer full growth.”
In the citing paper
“The growth rate of frost thickness, the heating capacity and COP of the heat pump increased as the frosting time elapsed until the column-type frost layer is generated.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Guo et al. [37]
In the citing paper
“For constant outdoor temperature, the duration of first and third stage of growth formation are similar for relative humidity ranging from 65% to 85%.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Guo et al. [37]
In the citing paper
“The duration of second stage decreased with increase of relative humidity.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Guo et al. [37]
In the citing paper
“Therefore, heating capacity and COP are slightly reduced.”
In the citing paper
“In last stage, due to increased rate of frost layer formation, the air flow rate decreases and thermal resistance increases affecting heating capacity and COP negatively.”
In the citing paper
“In initial stage of frost formation heating capacity of ASHP unit increased.”
In the citing paper
“In the second stage, frost layer increases, which reduces the evaporating pressure and airflow rate marginally.”
In the citing paper
“However, the pressure drop is relatively less.”
Citations
Cites
Yao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 152
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
Performance of finned tube heat exchangers operating under frosting conditions
Yan, W.-M., Li, H.-Y., Wu, Y.-J., Lin, J.-Y., & Chang, W.-R. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00346-0 · Cited by 95
Modeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94 · cited 2×
“In most of these experimental [1–4,7] and numerical [5,6] studies the air flow rate”
BackgroundResultLocal variation of frost layer thickness and morphology
Qu, K., Komori, S., & Jiang, Y. (2006) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2005.05.004 · Cited by 67
Effect of frost growth on the performance of louvered finned tube heat exchangers
Kondepudi, S. N., & O'Neal, D. L. (1989) · International Journal of Refrigeration · doi:10.1016/0140-7007(89)90030-3 · Cited by 67
Fan supplied heat exchanger fin performance under frosting conditions
Chen, H., Thomas, L., & Besant, R. W. (2003) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00011-7 · Cited by 59
Seker, D., Karatas, H., & Egrican, P. D. N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.004 · Cited by 56
Tso, C. P., Cheng, Y. C., & Lai, A. C. K. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.09.018 · Cited by 33
Experimental investigation on the performance of air cooler under frosting conditions
Deng, D.-Q., Xu, L., & Xu, S.-Q. (2003) · Applied Thermal Engineering · doi:10.1016/s1359-4311(03)00022-x · Cited by 30
Kondepudi, S. N., & O’Neal, D. L. (1993) · International Journal of Refrigeration · doi:10.1016/0140-7007(93)90046-b · Cited by 25
Tso, C. P., Cheng, Y. C., & Lai, A. C. K. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.09.012 · Cited by 6
Numerical Simulation on the Performance of Heat Pumps under Frost Conditions
Yue, R. (2005) · Refrigeration · Cited by 1
Flagged first, then by citations
3 of the 17 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- Senshu, 1990, Heat pump performance under frosting conditions: Part I – Heat and mass transfer on cross-finned tube heat exchangers under frosting conditions, ASHRAE Trans., 96, 324
- Yasuda, 1990, Heat pump performance under frosting conditions: Part II – Simulation of heat pump cycle characteristics under frosting conditions, ASHRAE Trans., 96, 330
- Miller, 1987, Laboratory examination and seasonal analysis of frosting and defrosting for an air-to-air heat pump, ASHRAE Trans., 93, 1474
- Guo, 2006, Numerical simulation and experimental verification on dynamic performance of air source heat pump under frosting conditions, J. Xi’an Jiaotong Univ., 40, 544
Cited by
Sorted by citations
Review on the measurement and calculation of frost characteristics
Song, M., & Dang, C. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.03.094 · Cited by 212
Review of energy efficiency and system performance of residential heat pump water heaters
Willem, H., Lin, Y., & Lekov, A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.023 · Cited by 199
Dong, J.-K., Deng, S., Jiang, Y.-Q., Xia, L., & Yao, Y. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.11.052 · Cited by 174
Effects of surface characteristic on frosting and defrosting behaviors of fin-tube heat exchangers
Wang, F., Liang, C., Yang, M., Fan, C., & Zhang, X. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.10.090 · Cited by 142
A review of heat pump systems for heating and cooling of buildings in China in the last decade
Ni, L., Dong, J., Yao, Y., Shen, C., Qv, D., & Zhang, X. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.06.043 · Cited by 142
Metadata
- Authors
- Guo, X.-M., Chen, Y.-G., Wang, W.-H., & Chen, C.-Z.
- Affiliations
- Tianjin University of Commerce (CN)
- Corresponding author
- Guo, Xian-Min
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 28
- Issue
- 17-18
- Pages
- 2267-2278
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2133344973
- Cited by
- 173
- References
- 17
- Citations by year
- 2026: 11 · 2025: 11 · 2024: 14 · 2023: 17 · 2022: 17 · 2021: 15 · 2020: 14 · 2019: 13 · 2018: 8 · 2017: 10 · 2016: 15 · 2015: 6 · 2014: 5 · 2013: 2 · 2012: 3
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- Beijing Municipal Science and Technology Commission
- Tianjin Science and Technology Committee
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air-source heat pump, frost growth, frost thickness, frost accumulation, heating capacity, coefficient of performance, ice crystal growth, relative humidity, ambient temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review