Ablation target cooling by maximizing the nanoparticle productivity in laser synthesis of colloids
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Waag et al. suggested that placing the focal spot slightly behind the target, 0.7-4.7 mm, increases nanoparticle productivity compared to placing the focal spot on the surface of the target at 0 mm.
“Nevertheless, Waag et al. 75 suggested that placing the focal spot slightly behind the target (0.7-4.7 mm) increases NP productivity compared to placing the focal spot on the surface of the target (0 mm) (Fig. 5).”
From Green nanoparticle synthesis at scale: a perspective on overcoming the limits of pulsed laser ablation in liquids for high-throughput production (2023) · cites this paper as [75]
The high temperature of the liquid is caused by heat released from the larger number of generated nanoparticles.
“The high temperature of the liquid is caused by the heat released from the larger number of generated NPs.75”
From Green nanoparticle synthesis at scale: a perspective on overcoming the limits of pulsed laser ablation in liquids for high-throughput production (2023) · cites this paper as [75]
Cites
Flash Method of Determining Thermal Diffusivity, Heat Capacity, and Thermal Conductivity
Parker, W. J., Jenkins, R. J., Butler, C. P., & Abbott, G. L. (1961) · Journal of Applied Physics · doi:10.1063/1.1728417 · Cited by 3,978 · see citing works
Sub-picosecond UV laser ablation of metals
Preuss, S., Demchuk, A., & Stuke, M. (1995) · Applied Physics A Materials Science & Processing · doi:10.1007/bf01538207 · Cited by 468 · see citing works
Streubel, R., Barcikowski, S., & Gökce, B. (2016) · Optics Letters · doi:10.1364/ol.41.001486 · Cited by 283 · see citing works
Self-citationGeneration of nanoparticle colloids by picosecond and femtosecond laser ablations in liquid flow
Barcikowski, S., Menéndez-Manjón, A., Chichkov, B., Brikas, M., & Račiukaitis, G. (2007) · Applied Physics Letters · doi:10.1063/1.2773937 · Cited by 225 · see citing works
Self-citationMenéndez-Manjón, A., Chichkov, B. N., & Barcikowski, S. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp909897v · Cited by 79 · see citing works
Self-citationSakaki, S., Ikenoue, H., Tsuji, T., Ishikawa, Y., & Koshizaki, N. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2017.10.235 · Cited by 33 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Khairani, I. Y., Mínguez-Vega, G., Doñate-Buendía, C., & Gökce, B. (2023) · Physical Chemistry Chemical Physics · doi:10.1039/d3cp01214j · Cited by 130 · see citing works
Self-citationWaag, F., Streubel, R., Gökce, B., & Barcikowski, S. (2021) · Applied Nanoscience · doi:10.1007/s13204-021-01693-y · Cited by 67 · see citing works
Self-citation
- Authors
- Waag, F., Gökce, B., & Barcikowski, S.
- Affiliations
- University of Duisburg-Essen (DE)
- Corresponding author
- Gökce, Bilal
- Venue
- Applied Surface Science
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 466
- Pages
- 647-656
- ISSN
- 0169-4332 (ISSN-L)
- OpenAlex
- W2894784852
- Cited by
- 19
- References
- 6
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 3 · 2019: 3
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Surface Science (publishedVersion)
- Funders
- Bundesministerium für Bildung und Forschung (03SF0497B)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Laser-Ablation Synthesis of Nanoparticles
- Physical Sciences › Engineering › Computational Mechanics › Laser Material Processing Techniques
- Physical Sciences › Engineering › Mechanics of Materials › Laser-induced spectroscopy and plasma
- Keywords
- laser ablation, ultrashort laser pulses, thermal energy conversion, target heating, nickel target, heat transfer, process control, time-resolved temperature measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review