The DOI matches its Crossref record.
Rotator Cuff Repair Using an Acellular Dermal Matrix Graft: An In Vivo Study in a Canine Model
Abstract
PURPOSE: Large rotator cuff tears present a challenge to orthopaedic surgeons. Because tissue may be insufficient or of inadequate quality to undergo repair, a variety of materials have been used as adjuncts. Human dermal tissue may be processed to render it acellular, and thus less immunogenic, but with the extracellular matrix left intact, creating a collagen scaffold with favorable characteristics. Because of these traits, use in rotator cuff repair was proposed. METHODS: A canine model for a full-thickness infraspinatus tendon tear was used. Tendon was excised from the bony interface to the myotendinous junction, and a human acellular dermal matrix graft (experimental) or the autologous excised tendon (control) was used to bridge the defect. Animals were sacrificed, and shoulders were evaluated histologically and biomechanically. RESULTS: At time 0, strength of control and experimental repairs was similar. At 6 weeks, the strength of the experimental repair was half that of the control side. Strength of control specimens remained the same at 6 and 12 weeks, but by 12 weeks, the strength of the experimental repair was equal to that of the control. Histologically, cells infiltrated the control and experimental specimens by 6 weeks; chronic inflammation was consistent with surgery and repair. At 6 months, control and experimental specimens mimicked normal tendon structure grossly and histologically. CONCLUSIONS: Use of human acellular dermal matrix as a patch is a viable option in this model of large rotator cuff defects. Within 6 weeks, histologic evidence of native cell infiltration and neotendon development was observed. Within 12 weeks, the strength of the dermal matrix graft repair was equivalent to that of autologous tendon. At 6 months, control and graft specimens mimicked normal tendon structure grossly and histologically. CLINICAL RELEVANCE: This study provides in vivo animal data to support the use of this acellular dermal matrix graft for repair of full-thickness rotator cuff defects. Additional studies are indicated to determine the role of this material in the treatment of humans with rotator cuff tears.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Docheva, D., Müller, S. A., Majewski, M., & Evans, C. H. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.015 · Cited by 693
Consequences of ineffective decellularization of biologic scaffolds on the host response
Keane, T. J., Londono, R., Turner, N. J., & Badylak, S. F. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.054 · Cited by 613
Mechanisms of tendon injury and repair
Thomopoulos, S., Parks, W. C., Rifkin, D. B., & Derwin, K. A. (2015) · Journal of Orthopaedic Research · doi:10.1002/jor.22806 · Cited by 564
Barber, F. A., Burns, J. P., Deutsch, A., Labbé, M. R., & Litchfield, R. B. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.06.038 · Cited by 433
Cheng, C. W., Solorio, L. D., & Alsberg, E. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.12.012 · Cited by 358
Tendon augmentation grafts: a systematic review
Longo, U. G., Lamberti, A., Maffulli, N., & Denaro, V. (2010) · British Medical Bulletin · doi:10.1093/bmb/ldp051 · Cited by 280
Keane, T. J., & Badylak, S. F. (2015) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1874 · Cited by 139
Metadata
- Authors
- Adams, J. E., Zobitz, M. E., Reach, J. S., An, K.-N., & Steinmann, S. P.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2006-07
- Volume
- 22
- Issue
- 7
- Pages
- 700-709
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2080807232
- Cited by
- 248
- References
- 0
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.