CoChat

Intra-Articular Injections of Mesenchymal Stem Cell Exosomes and Hyaluronic Acid Improve Structural and Mechanical Properties of Repaired Cartilage in a Rabbit Model

Wong, Keng Lin, Zhang, Shipin, Wang, Ming, Ren, Xiafei, Afizah, Hassan, Lai, Ruenn Chai, Lim, Sai Kiang, Lee, Eng Hin, Hui, James Hoi Po, Toh, Wei Seong · 2020 · Arthroscopy: The Journal of Arthroscopic & Related Surgery
Cited by 89

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare the efficacy of mesenchymal stem cell (MSC) exosomes with hyaluronic acid (HA) against HA alone for functional cartilage regeneration in a rabbit osteochondral defect model. METHODS: Critical-size osteochondral defects (4.5-mm diameter and 1.5-mm depth) were created on the trochlear grooves in the knees of 18 rabbits and were randomly allocated to 2 treatment groups: (1) exosomes and HA combination and (2) HA alone. Three 1-mL injections of either exosomes and HA or HA alone were administered intra-articularly immediately after surgery and thereafter at 7 and 14 days after surgery. At 6 and 12 weeks, gross evaluation, histologic and immunohistochemical analysis, and scoring were performed. The functional biomechanical competence of the repaired cartilage also was evaluated. RESULTS: Compared with defects treated with HA, defects treated with exosomes and HA showed significant improvements in macroscopic scores (P = .032; P = .001) and histologic scores (P = .005; P < .001) at 6 and 12 weeks, respectively. Defects treated with exosomes and HA also demonstrated improvements in mechanical properties compared with HA-treated defects, with significantly greater Young's moduli (P < .05) and stiffness (P < .05) at 6 and 12 weeks. By 12 weeks, the newly-repaired tissues in defects treated with exosomes and HA composed mainly of hyaline cartilage that are mechanically and structurally superior to that of HA-treated defects and demonstrated mechanical properties that approximated that of adjacent native cartilage (P > .05). In contrast, HA-treated defects showed some repair at 6 weeks, but this was not sustained, as evidenced by significant deterioration of histologic scores (P = .002) and a plateau in mechanical properties from 6 to 12 weeks. CONCLUSIONS: This study shows that the combination of MSC exosomes and HA administered at a clinically acceptable frequency of 3 intra-articular injections can promote sustained and functional cartilage repair in a rabbit post-traumatic cartilage defect model, when compared with HA alone. CLINICAL RELEVANCE: Human MSC exosomes and HA administered in combination promote functional cartilage repair and may represent a promising cell-free therapy for cartilage repair in patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2020.03.031

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 89

Metadata

Authors
Wong, K. L., Zhang, S., Wang, M., Ren, X., Afizah, H., Lai, R. C., Lim, S. K., Lee, E. H., Hui, J. H. P., & Toh, W. S.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2020-08
Volume
36
Issue
8
Pages
2215-2228.e2
ISSN
0749-8063 (ISSN-L)
OpenAlex
W3017207119
Cited by
89
References
6
FWCI
9.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intra-Articular Injections of Mesenchymal Stem Cell Exosomes and Hyaluronic Acid Improve Structural and Mechanical Properties of Repaired Cartilage in a Rabbit Model. https://app.cochat.ai/papers/10.1016/j.arthro.2020.03.031
The paper
Wong, K. L., Zhang, S., Wang, M., Ren, X., Afizah, H., Lai, R. C., Lim, S. K., Lee, E. H., Hui, J. H. P., & Toh, W. S. (2020). Intra-Articular Injections of Mesenchymal Stem Cell Exosomes and Hyaluronic Acid Improve Structural and Mechanical Properties of Repaired Cartilage in a Rabbit Model. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2020.03.031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.