Liver segmentation from computed tomography scans: A survey and a new algorithm
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004 · cited 1×
“This binary volume is used as a liver mask to select, from the result of the Canny edge detector [24], the external boundaries of the liver.”
MethodPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-21955-6 · Cited by 4,596
An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Shape modeling with front propagation: a level set approach
Malladi, R., Sethian, J. A., & Vemuri, B. C. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.368173 · Cited by 3,158 · cited 1×
“They employ a 2D and 3D level-set approach [42] based on a novel speed function.”
MethodWhat energy functions can be minimized via graph cuts?
Kolmogorov, V., & Zabih, R. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.1262177 · Cited by 3,127
Hierarchical chamfer matching: a parametric edge matching algorithm
Borgefors, G. (1988) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.9107 · Cited by 1,056 · cited 2×
“To evaluate their system the authors select 10 out of 40 patients and compute the average 3=4 Chamfer distance [30] among manual and automatic segmentation.”
MethodUse of active shape models for locating structures in medical images
Cootes, T., Hill, A., Taylor, C., & Haslam, J. (1994) · Image and Vision Computing · doi:10.1016/0262-8856(94)90060-4 · Cited by 910 · cited 1×
“Lamecker [34] tries to achieve robustness to noise and outliers by creating a statistical shape model inspired to the work of Cootes [35].”
MethodSafety of Donors in Live Donor Liver Transplantation Using Right Lobe Grafts
Fan, S.-T. (2000) · Archives of Surgery · doi:10.1001/archsurg.135.3.336 · Cited by 452 · cited 1×
“More precisely, the current interests are as follows: automatic detection of liver cancer [1] or other liver diseases [2]; measurement of liver volume [3], an important index in cases of living donor liver transplantation; 3D liver volume rendering [4,5], helpful both for surgical planning prior to hepatic resection […”
BackgroundShape-based interpolation of multidimensional objects
Raya, S. P., & Udupa, J. K. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52980 · Cited by 435 · cited 1×
“Besides, the use of a shape-based interpolation method [13] reduces the number of slices that must be interactively segmented, for it can calculate all the missing contours automatically.”
MethodInteractive live-wire boundary extraction
Barrett, W. A., & Mortensen, E. N. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85005-0 · Cited by 334 · cited 1×
“The live wire algorithms [8] are a class of usersteered methods used to segment different types of medical images [9].”
MethodConstruction of an abdominal probabilistic atlas and its application in segmentation
Park, H., Bland, P. H., & Meyer, C. R. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809139 · Cited by 328 · cited 3×
“655 pixels Gao [31] Model fitting, 21 patients Visual inspection Montagnat [32,33] Model fitting, 5 patients avg surface distance 1⁄4 2 mm Lamecker [34] Model fitting, 33 patients avg SVD 1⁄4 5:25%, dMeanðS; S0Þ 1⁄4 2:3 mm Park [37] Probabilistic atlases, 20 patients avg SensRatio 1⁄4 91:5% Zhou [39] Probabilistic atl…”
BackgroundSoler, L., Delingette, H., Malandain, G., Montagnat, J., Ayache, N., Koehl, C., Dourthe, O., Malassagne, B., Smith, M., Mutter, D., et al. (2001) · Computer Aided Surgery · doi:10.1002/igs.1016 · Cited by 320
Automatic liver segmentation technique for three-dimensional visualization of CT data.
Gao, L., Heath, D. G., Kuszyk, B. S., & Fishman, E. K. (1996) · Radiology · doi:10.1148/radiology.201.2.8888223 · Cited by 177 · cited 3×
“While in [7,17,18] the authors provide only a visual assessment of their results, in [16] the authors objectively test their system on a very small data set (94 slices from 4 patients).”
BackgroundMethodAutomated Hepatic Volumetry for Living Related Liver Transplantation At Multisection CT
Nakayama, Y., Li, Q., Katsuragawa, S., Ikeda, R., Hiai, Y., Awai, K., Kusunoki, S., Yamashita, Y., Okajima, H., Inomata, Y., et al. (2006) · Radiology · doi:10.1148/radiol.2403050850 · Cited by 177 · cited 1×
“More precisely, the current interests are as follows: automatic detection of liver cancer [1] or other liver diseases [2]; measurement of liver volume [3], an important index in cases of living donor liver transplantation; 3D liver volume rendering [4,5], helpful both for surgical planning prior to hepatic resection […”
BackgroundEfficient Semiautomatic Segmentation of 3D Objects in Medical Images
Schenk, A., Prause, G., & Peitgen, H.-O. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_19 · Cited by 174
Automatic segmentation of liver structure in CT images
Bae, K. T., Giger, M. L., Chen, C., & Kahn, C. E. (1993) · Medical Physics · doi:10.1118/1.597064 · Cited by 151 · cited 2×
“While in [7,17,18] the authors provide only a visual assessment of their results, in [16] the authors objectively test their system on a very small data set (94 slices from 4 patients).”
BackgroundMethodAutomatic liver segmentation for volume measurement in CT Images
Lim, S., Jeong, Y., & Ho, Y. (2005) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2005.07.001 · Cited by 139 · cited 1×
“In the literature [22,43], this is usually done by complex techniques (eg.”
MethodLiver Segmentation in Living Liver Transplant Donors: Comparison of Semiautomatic and Manual Methods
Hermoye, L., Laamari-Azjal, I., Cao, Z., Annet, L., Lerut, J. P., Dawant, B. M., & BEERS, B. E. V. (2005) · Radiology · doi:10.1148/radiol.2341031801 · Cited by 132 · cited 1×
“As a result, the inter- and intra-observer repeatability is not higher than that obtained with manual segmentation [15]; an example of variability among liver contours traced both by two experts at the same time, and by the same expert at different times is shown in Fig.”
BackgroundLiver segmentation for CT images using GVF snake
Liu, F., Zhao, B., Kijewski, P. K., Wang, L., & Schwartz, L. H. (2005) · Medical Physics · doi:10.1118/1.2132573 · Cited by 130 · cited 4×
“Liu computes the histogram of the whole volume to identify the liver peak in a preset gray-level range, and determines two liver thresholds, one at each side of the liver peak.”
MethodInfluentialSegmentation of the Liver using a 3D Statistical Shape Model
Lamecker, H., Lange, T., & Seebaß, M. (2004) · Cited by 112
Abdominal organ segmentation using texture transforms and a Hopfield neural network
Koss, J. E., Newman, F., Johnson, T. K., & Kirch, D. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.790463 · Cited by 104 · cited 4×
“Examples are the works presented by Tsai and Nobutaka [26], Koss et al. [27], and Lee et al. [28,29].”
BackgroundMethodInfluentialFrericks, B. B., Caldarone, F. C., Nashan, B., Savellano, D. H., Stamm, G., Kirchhoff, T. D., Shin, H., Schenk, A., Selle, D., Spindler, W., et al. (2004) · European Radiology · doi:10.1007/s00330-003-2161-8 · Cited by 94 · cited 1×
“Although these improvements, this method still requires the user interaction time [14]; this problem apart, its main drawback, which is common to all the semi-automatic segmentation techniques, is due to the fact that the quality of the segmentation result is heavily dependent on the operator’s skill, suffering from i…”
MethodAutomatic 3D segmentation of the liver from abdominal CT images: a level-set approach
Pan, S., & Dawant, B. M. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.431019 · Cited by 91 · cited 2×
“655 pixels Gao [31] Model fitting, 21 patients Visual inspection Montagnat [32,33] Model fitting, 5 patients avg surface distance 1⁄4 2 mm Lamecker [34] Model fitting, 33 patients avg SVD 1⁄4 5:25%, dMeanðS; S0Þ 1⁄4 2:3 mm Park [37] Probabilistic atlases, 20 patients avg SensRatio 1⁄4 91:5% Zhou [39] Probabilistic atl…”
BackgroundVolumetric medical images segmentation using shape constrained deformable models
Montagnat, J., & Delingette, H. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029220 · Cited by 81 · cited 4×
“655 pixels Gao [31] Model fitting, 21 patients Visual inspection Montagnat [32,33] Model fitting, 5 patients avg surface distance 1⁄4 2 mm Lamecker [34] Model fitting, 33 patients avg SVD 1⁄4 5:25%, dMeanðS; S0Þ 1⁄4 2:3 mm Park [37] Probabilistic atlases, 20 patients avg SensRatio 1⁄4 91:5% Zhou [39] Probabilistic atl…”
BackgroundMethodInfluentialLocal-cost computation for efficient segmentation of 3D objects with live wire
Schenk, A., Prause, G. P. M., & Peitgen, H. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.431015 · Cited by 41 · cited 1×
“In [10,11], Schenk et al.”
Segmentation of the Liver Using the Deformable Contour Method on CT Images
Lim, S., Jeong, Y., & Ho, Y. (2005) · Lecture notes in computer science · doi:10.1007/11581772_50 · Cited by 35
Lim, S., Jeong, Y., Lee, C.-W., & Ho, Y. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.533586 · Cited by 35
Phase-Based User-Steered Image Segmentation
O’Donnell, L. J., Westin, C., Grimson, W. E. L., Ruiz‐Alzola, J., Shenton, M. E., & Kikinis, R. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_122 · Cited by 25 · cited 1×
“The live wire algorithms [8] are a class of usersteered methods used to segment different types of medical images [9].”
MethodNeural-network-based boundary detection of liver structure in CT images for 3-D visualization
Tsai, D., & Tanahashi, N. (1994) · IEEE International Conference on Neural Networks/IEEE ... International Conference on Neural Networks · doi:10.1109/icnn.1994.374895 · Cited by 23
Classification of Liver Diseases from CT Images Using BP-CMAC Neural Network
Lee, C.-C., Chung, P., & Chen, Y. M. (2005) · International Workshop on Cellular Neural Networks and Their Applications · doi:10.1109/cnna.2005.1543175 · Cited by 17 · cited 1×
“More precisely, the current interests are as follows: automatic detection of liver cancer [1] or other liver diseases [2]; measurement of liver volume [3], an important index in cases of living donor liver transplantation; 3D liver volume rendering [4,5], helpful both for surgical planning prior to hepatic resection […”
BackgroundFrericks, B. B., Kirchhoff, T. D., Shin, H., Stamm, G., Merkesdal, S., Abe, T., Schenk, A., Peitgen, H., Klempnauer, J. L., Galanski, M., et al. (2006) · European Radiology · doi:10.1007/s00330-006-0274-6 · Cited by 17 · cited 1×
“This technique, which is the basic step of the HepaVision software tool [12] currently used in the clinical practice, computes the cost function in a tube-like area around the liver contour copied from the nearest”
Method
Cited by
The Medical Segmentation Decathlon
Antonelli, M., Reinke, A., Bakas, S., Farahani, K., Kopp-Schneider, A., Landman, B. A., Litjens, G., Menze, B., Ronneberger, O., Summers, R. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-30695-9 · Cited by 1,384
“Most of the observed task-specific performances reflect the natural difficulty and expected inter-rater variability of the tasks: Liver and spleen are large organs that are easy to detect and outline [33], whereas pancreas and colon cancers are much harder to segment as annotation experts themselves often do not agree…”
Background3D deeply supervised network for automated segmentation of volumetric medical images
Dou, Q., Yu, L., Chen, H., Jin, Y., Yang, X., Qin, J., & Heng, P.-A. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.05.001 · Cited by 613
SimpleElastix: A User-Friendly, Multi-lingual Library for Medical Image Registration
Marstal, K., Berendsen, F., Staring, M., & Klein, S. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2016.78 · Cited by 325
Liver segmentation: indications, techniques and future directions
Gotra, A., Sivakumaran, L., Chartrand, G., Vu, K.-N., Vandenbroucke-Menu, F., Kauffmann, C., Kadoury, S., Gallix, B., de Guise, J. A., & Tang, A. (2017) · Insights into Imaging · doi:10.1007/s13244-017-0558-1 · Cited by 225
“D) livewire technique serves as the basis for the software HepaVision® created by MeVisLab [7, 13].”
Automatic Liver Segmentation Based on Shape Constraints and Deformable Graph Cut in CT Images
Li, G., Chen, X., Shi, F., Zhu, W., Tian, J., & Xiang, D. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2481326 · Cited by 185
“A comprehensive review of different methods have been presented [3], [8].”
Method
Metadata
- Authors
- Campadelli, P., Casiraghi, E., & Esposito, A.
- Venue
- Artificial Intelligence in Medicine
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 45
- Issue
- 2-3
- Pages
- 185-196
- ISSN
- 0933-3657 (ISSN-L)
- OpenAlex
- W1996565856
- Cited by
- 197
- References
- 33
- FWCI
- 10.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.