Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 395

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Automated medical diagnosis of COVID-19 through EfficientNet convolutional neural network

Open access
Marques, Gonçalo, Agarwal, Deevyankar, de la Torre Díez, Isabel·2020·Applied Soft Computing

Abstract

COVID-19 infection was reported in December 2019 at Wuhan, China. This virus critically affects several countries such as the USA, Brazil, India and Italy. Numerous research units are working at their higher level of effort to develop novel methods to prevent and control this pandemic scenario. The main objective of this paper is to propose a medical decision support system using the implementation of a convolutional neural network (CNN). This CNN has been developed using EfficientNet architecture. To the best of the authors’ knowledge, there is no similar study that proposes an automated method for COVID-19 diagnosis using EfficientNet. Therefore, the main contribution is to present the results of a CNN developed using EfficientNet and 10-fold stratified cross-validation. This paper presents two main experiments. First, the binary classification results using images from COVID-19 patients and normal patients are shown. Second, the multi-class results using images from COVID-19, pneumonia and normal patients are discussed. The results show average accuracy values for binary and multi-class of 99.62% and 96.70%, respectively. On the one hand, the proposed CNN model using EfficientNet presents an average recall value of 99.63% and 96.69% concerning binary and multi-class, respectively. On the other hand, 99.64% is the average precision value reported by binary classification, and 97.54% is presented in multi-class. Finally, the average F1-score for multi-class is 97.11%, and 99.62% is presented for binary classification. In conclusion, the proposed architecture can provide an automated medical diagnostics system to support healthcare specialists for enhanced decision making during this pandemic scenario.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.asoc.2020.106691

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Cited by

See all 395

Metadata

Authors
Marques, G., Agarwal, D., & de la Torre Díez, I.
Venue
Applied Soft Computing
Publisher
Elsevier BV
Published
2020-11
Volume
96
Pages
106691
ISSN
1568-4946 (ISSN-L)
OpenAlex
W3080406710
Cited by
395
References
52
FWCI
27.34
Type
journal article
Language
en
Open access
green
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
  • Ministerio de Industria, Energía y Turismo (AAL-20125036)
  • European Commission

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated medical diagnosis of COVID-19 through EfficientNet convolutional neural network. https://app.cochat.ai/papers/10.1016/j.asoc.2020.106691
The paper
Marques, G., Agarwal, D., & de la Torre Díez, I. (2020). Automated medical diagnosis of COVID-19 through EfficientNet convolutional neural network. Applied Soft Computing. https://doi.org/10.1016/j.asoc.2020.106691

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.