The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Biosensors based on electrochemical lactate detection: A comprehensive review
Open accessAbstract
Lactate detection plays a significant role in healthcare, food industries and is specially necessitated in conditions like hemorrhage, respiratory failure, hepatic disease, sepsis and tissue hypoxia. Conventional methods for lactate determination are not accurate and fast so this accelerated the need of sensitive biosensors for high-throughput screening of lactate in different samples. This review focuses on applications and developments of various electrochemical biosensors based on lactate detection as lactate being essential metabolite in anaerobic metabolic pathway. A comparative study to summarize the L-lactate biosensors on the basis of different analytical properties in terms of fabrication, sensitivity, detection limit, linearity, response time and storage stability has been done. It also addresses the merits and demerits of current enzyme based lactate biosensors. Lactate biosensors are of two main types - lactate oxidase (LOD) and lactate dehydrogenase (LDH) based. Different supports tried for manufacturing lactate biosensors include membranes, polymeric matrices-conducting or non-conducting, transparent gel matrix, hydrogel supports, screen printed electrodes and nanoparticles. All the examples in these support categories have been aptly discussed. Finally this review encompasses the conclusion and future emerging prospects of lactate sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angus, D. C., Linde-Zwirble, W. T., Lidicker, J., Clermont, G., Carcillo, J., & Pinsky, M. R. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00002 · Cited by 8,503
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Methods of Biochemical Analysis
(1956) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1956.tb56924.x · Cited by 4,466
THE COLORIMETRIC DETERMINATION OF LACTIC ACID IN BIOLOGICAL MATERIAL
Barker, S. B., & Summerson, W. H. (1941) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)51379-x · Cited by 3,431
Park, H., Harris, S. M., Boldenow, E., Aronoff, D. M., Rea, M., Xi, C., & Loch‐Caruso, R. (2024) · American Journal of Reproductive Immunology · doi:10.1111/aji.13807 · Cited by 2,087
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Early lactate clearance is associated with improved outcome in severe sepsis and septic shock*
Nguyen, H. B., Rivers, E. P., Knoblich, B. P., Jacobsen, G., Muzzin, A., Ressler, J. A., & Tomlanovich, M. C. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000132904.35713.a7 · Cited by 1,228
Bakker, J., Gris, P., Coffernils, M., Kahn, R. J., & Vincent, J.-L. (1996) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)89552-9 · Cited by 851
Peng, K., Li, J., Cheng, H., & Ji, F.-H. (2014) · Medical Principles and Practice · doi:10.1159/000363573 · Cited by 641
Self-assembled Monolayers for Biosensors
Wink, T., van Zuilen, S. J., Bult, A., & van Bennekom, W. P. (1997) · The Analyst · doi:10.1039/a606964i · Cited by 634
Blood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians
Goodwin, M. L., Harris, J. E., Hernández, A., & Gladden, L. B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100414 · Cited by 554
Recent developments and applications of screen-printed electrodes in environmental assays—A review
Li, M., Li, Y.-T., Li, D.-W., & Long, Y.-T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.018 · Cited by 550
Electrochemical Sensors Based on Organic Conjugated Polymers
Rahman, M. A., Kumar, P., Park, D.-S., & Shim, Y.-B. (2008) · Sensors · doi:10.3390/s8010118 · Cited by 464
Magnetic resonance spectroscopy of the brain: review of metabolites and clinical applications
Soares, D. P., & Law, M. (2009) · Clinical Radiology · doi:10.1016/j.crad.2008.07.002 · Cited by 459
Base excess and lactate as prognostic indicators for patients admitted to intensive care
Smith, I., Kumar, P., Molloy, S., Rhodes, A., Newman, P. J., Grounds, R. M., & Bennett, E. D. (2001) · Intensive Care Medicine · doi:10.1007/s001340051352 · Cited by 407
The sol-gel encapsulation of enzymes
Pierre, A. C. (2004) · Biocatalysis and Biotransformation · doi:10.1080/10242420412331283314 · Cited by 384
Sol−Gel Materials in Electrochemistry
Lev, O. E., Wu, Z., Bharathi, S., Glezer, V., Modestov, A. D., Gun, J., Rabinovich, L., & Sampath, S. (1997) · Chemistry of Materials · doi:10.1021/cm970367b · Cited by 369
Uribarri, J., Oh, M. S., & Carroll, H. J. (1998) · Medicine · doi:10.1097/00005792-199803000-00001 · Cited by 326
Electron-transfer mechanisms in amperometric biosensors
Habermüller, K., Mosbach, M., & Schuhmann, W. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051551 · Cited by 310
Enzyme Based Amperometric Biosensors for Food Analysis
Prodromidis, M. I., & Karayannis, M. I. (2002) · Electroanalysis · doi:10.1002/1521-4109(200202)14:4<241::aid-elan241>3.0.co;2-p · Cited by 298
Amperometric biosensors for clinical and therapeutic drug monitoring: a review
Wang, J. (1999) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00056-9 · Cited by 293
Mediator compounds for the electrochemical study of biological redox systems: a compilation
Fultz, M. L., & Durst, R. A. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95447-9 · Cited by 283
Recent advances in material science for developing enzyme electrodes
Sarma, A. K., Vatsyayan, P., Goswami, P., & Minteer, S. D. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.026 · Cited by 282
Biosensors based on electropolymerized films: new trends
Cosnier, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2131-7 · Cited by 259
Bench-to-bedside review: lactate and the kidney.
Bellomo, R. (2002) · Critical Care · doi:10.1186/cc1518 · Cited by 237
Use of polymer films in amperometric biosensors
Emr, S. A., & Yacynych, A. M. (1995) · Electroanalysis · doi:10.1002/elan.1140071002 · Cited by 202
Lactate Production by the Lungs in Acute Lung Injury
DE BACKER, D., CRETEUR, J., ZHANG, H., NORRENBERG, M., & VINCENT, J.-L. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.4.9701048 · Cited by 190
Lactate as a marker of energy failure in critically ill patients: hypothesis.
Valenza, F., Aletti, G., Fossali, T., Chevallard, G., Sacconi, F., Irace, M., & Gattinoni, L. (2005) · Critical Care · doi:10.1186/cc3818 · Cited by 152
Teymourian, H., Salimi, A., & Hallaj, R. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.12.031 · Cited by 152
Chaubey, A., Gerard, M., Singhal, R., -, V. S., & Malhotra, B. D. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00658-7 · Cited by 147
Nikolaus, N., & Strehlitz, B. (2007) · Microchimica Acta · doi:10.1007/s00604-007-0834-8 · Cited by 142
Palmisano, F., Rizzi, R., Centonze, D., & Zambonin, P. G. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00107-x · Cited by 140
Co-immobilization of lactate oxidase and lactate dehydrogenase on conducting polyaniline films
Chaubey, A., Pande, K. K., -, V. S., & Malhotra, B. D. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00797-7 · Cited by 128
Stekelenburg, F. K., & Kant-Muermans, M. L. T. (2001) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(00)00521-3 · Cited by 119
Highly sensitive lactate biosensor by engineering chitosan/PVI-Os/CNT/LOD network nanocomposite
Cui, X., Li, C. M., Zang, J., & Yu, S. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.03.004 · Cited by 118
Significance of blood lactate levels in critically III patients with liver disease
Kruse, J. A., Zaidi, S. A., & Carlson, R. W. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90500-6 · Cited by 116
Electrochemical L-Lactic Acid Sensor Based on Immobilized ZnO Nanorods with Lactate Oxidase
Ibupoto, Z. H., Ali, S. M. U., Khun, K., & Willander, M. (2012) · Sensors · doi:10.3390/s120302456 · Cited by 112
Interventions to reduce mortality among patients treated in Intensive Care Units
Pronovost, P. J., Rinke, M. L., Emery, K., Himmelfarb, C. D., Blackledge, C. G., & Berenholtz, S. M. (2004) · Journal of Critical Care · doi:10.1016/j.jcrc.2004.07.003 · Cited by 104
Lactate/Pyruvate Ratio as a Marker of Tissue Hypoxia in Circulatory and Septic Shock
Rimachi, R., Carvahlo, F. B., Orellano-Jimenez, C., COTTON, F. J., Vincent, J., & Backer, D. D. (2012) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1204000307 · Cited by 102
Nesakumar, N., Sethuraman, S., Krishnan, U. M., & Rayappan, J. B. B. (2013) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2013.08.009 · Cited by 98
Patel, N. G., Erlenkötter, A., Cammann, K., & Chemnitius, G. C. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00410-x · Cited by 87
Nanostructured rough gold electrodes for the development of lactate oxidase-based biosensors
Gamero, M., Pariente, F., Lorenzo, E., & Alonso, C. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.01.032 · Cited by 87
Lactate accumulation, proton buffering, and pH change in ischemically exercising muscle
Kemp, G. J. (2005) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00641.2004 · Cited by 84
Haghighi, B., & Bozorgzadeh, S. (2011) · Talanta · doi:10.1016/j.talanta.2011.07.071 · Cited by 78
Park, T., Iwuoha, E. I., Smyth, M. R., Freaney, R., & McShane, A. J. (1997) · Talanta · doi:10.1016/s0039-9140(96)02164-9 · Cited by 78
Sprules, S. D., Hart, J. P., Wring, S. A., & Pittson, R. W. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00565-4 · Cited by 74
Zanini, V. I. P., de Mishima, B. L., & Solı́s, V. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.11.026 · Cited by 72
New Whole Blood Analyzers and Their Impact on Cardiac and Critical Care
Kost, G. J., & McQueen, M. (1993) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408369309084667 · Cited by 66
A lactate electrochemical biosensor with a titanate nanotube as direct electron transfer promoter
Yang, M., Wang, J., Li, H., Zheng, J., & Wu, N. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/7/075502 · Cited by 64
Pathogenesis and Management of Lactic Acidosis
Kreisberg, R. A. (1984) · Annual Review of Medicine · doi:10.1146/annurev.me.35.020184.001145 · Cited by 64
Reagentless enzyme electrodes for ethanol, lactate, and malate
Blaedel, W. J., & Engstrom, R. C. (1980) · Analytical Chemistry · doi:10.1021/ac50061a036 · Cited by 62
Ghamouss, F., Ledru, S., Ruillé, N., Lantier, F., & Boujtita, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.022 · Cited by 58
Kenausis, G., Taylor, C., Katakis, I., & Heller, A. (1996) · Journal of the Chemical Society Faraday Transactions · doi:10.1039/ft9969204131 · Cited by 57
Salazar, P., Martín, M. E., O'Neill, R. D., Roche, R., & González–Mora, J. L. (2011) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2011.11.047 · Cited by 55
Hajizadeh, K., Halsall, H. B., & Heineman, W. R. (1991) · Talanta · doi:10.1016/0039-9140(91)80007-m · Cited by 53
Development of a potentiometric biosensor based on nanostructured surface for lactate determination
Lupu, A., Valsesia, A., Brétagnol, F., Colpo, P., & Rossi, F. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.05.020 · Cited by 52
Kwan, R. C. H., Hon, P. Y. T., Mak, K. K. W., & Renneberg, R. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.008 · Cited by 50
Fowler, R., Hill-Popper, M., Stasinos, J., Petrou, C., Sanders, G. D., & Garber, A. M. (2003) · Journal of Critical Care · doi:10.1016/j.jcrc.2003.08.009 · Cited by 48
Milagres, M. P., Brandão, S. C. C., Magalhães, M. A., Minim, V. P. R., & Minim, L. A. (2012) · Food Chemistry · doi:10.1016/j.foodchem.2012.05.047 · Cited by 48
Shapiro, F., & Silanikove, N. (2011) · Food Chemistry · doi:10.1016/j.foodchem.2011.04.074 · Cited by 46
Meyerhoff, C., Bischof, F., Mennel, F. J., Sternberg, F., Bican, J., & Pfeiffer, E. F. (1993) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(93)80025-k · Cited by 43
Yu, Y., Yang, Y., Gu, H. C., Zhou, T., & Shi, G. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.055 · Cited by 43
Haccoun, J., Piro, B., Tran, L. D., Dang, L. A., & Pham, M. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.006 · Cited by 43
Casero, E., Alonso, C., Petit‐Domínguez, M. D., Vázquez, L., Parra-Alfambra, A. M., Merino, P., Álvarez‐García, S., de Andrés, A., Suárez, E., Pariente, F., et al. (2013) · Microchimica Acta · doi:10.1007/s00604-013-1070-z · Cited by 42
Karlsson, J., Willerson, J. T., Leshin, S. J., Mullins, C. B., & Mitchell, J. H. (1975) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365517509068008 · Cited by 36
Salazar, P., Martín, M. E., O'Neill, R. D., Roche, R., & González–Mora, J. L. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)19451-x · Cited by 36
Schmitt, R. E., Molitor, H. R., & Wu, T. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)16906-9 · Cited by 34
Stability of immobilized enzymes as biosensors for continuous application in vitro and in vivo
Abel, P., von Woedtke, T., Schulz, B., Bergann, T., & Schwock, A. (1999) · Journal of Molecular Catalysis B Enzymatic · doi:10.1016/s1381-1177(99)00024-7 · Cited by 29
Ren, J., Sherry, A. D., & Malloy, C. R. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24526 · Cited by 20
Cited by
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Direct metabolite detection with an n-type accumulation mode organic electrochemical transistor
Pappa, A. M., Ohayon, D., Giovannitti, A., Maria, I. P., Savva, A., Uguz, I., Rivnay, J., McCulloch, I., Owens, R. M., & Inal, S. (2018) · Science Advances · doi:10.1126/sciadv.aat0911 · Cited by 269
Microneedle-based biosensor for minimally-invasive lactate detection
Bollella, P., Sharma, S., Cass, A. E. G., & Antiochia, R. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.010 · Cited by 267
Wearable multiplexed biosensor system toward continuous monitoring of metabolites
Yokus, M. A., Songkakul, T., Pozdin, V. A., Bozkurt, A., & Daniele, M. A. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112038 · Cited by 153
Metadata
- Authors
- Rathee, K., Dhull, V., Dhull, R., & Singh, S.
- Venue
- Biochemistry and Biophysics Reports
- Publisher
- Elsevier BV
- Published
- 2016-03
- Volume
- 5
- Pages
- 35-54
- ISSN
- 2405-5808 (ISSN-L)
- OpenAlex
- W2184102879
- Cited by
- 362
- References
- 69
- FWCI
- 10.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.