Contact activation of blood-plasma coagulation
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
This opinion identifies inconsistencies in the generally-accepted surface biophysics involved in contact activation of blood-plasma coagulation, reviews recent experimental work aimed at resolving inconsistencies, and concludes that this standard paradigm requires substantial revision to accommodate new experimental observations. Foremost among these new findings is that surface-catalyzed conversion of the blood zymogen factor XII (FXII, Hageman factor) to the enzyme FXIIa ( FXII→surfaceFXIIa, a.k.a. autoactivation) is not specific for anionic surfaces, as proposed by the standard paradigm. Furthermore, it is found that surface activation is moderated by the protein composition of the fluid phase in which FXII autoactivation occurs by what appears to be a protein adsorption-competition effect. Both of these findings argue against the standard view that contact activation of plasma coagulation is potentiated by assembly of activation-complex proteins (FXII, FXI, prekallikrein, and high-molecular-weight kininogen) directly onto activating surfaces (procoagulants) through specific protein/surface interactions. These new findings supplement the observation that adsorption behavior of FXII and FXIIa is not remarkably different from a wide variety of other blood proteins surveyed. Similarity in adsorption properties further undermines the idea that FXII and/or FXIIa are distinguished from other blood proteins by unusual adsorption properties resulting in chemically-specific interactions with activating anionic surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surfactants and interfacial phenomena
(2005) · Choice Reviews Online · doi:10.5860/choice.42-2832 · Cited by 5,395
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
National Vital Statistics Reports
(2005) · Encyclopedia of Human Development · doi:10.4135/9781412952484.n432 · Cited by 2,921
Hemostasis and Thrombosis: Basic Principles and Clinical Practice.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-504_7 · Cited by 1,854
Structure and reactivity of water at biomaterial surfaces
Vogler, E. A. (1998) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(97)00040-7 · Cited by 1,640
Self-citationSurfactants and interfacial phenomena
Goddard, E. D. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90273-x · Cited by 771
Hemostasis and Thrombosis: Basic Principles and Clinical Practice
Francis, J. L. (1994) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-199410000-00031 · Cited by 715
(2001) · PubMed · Cited by 612
Cited by
Franz, S., Rammelt, S., Scharnweber, D., & Simon, J. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.078 · Cited by 1,391
Prevention of Intravascular Catheter-Related Infections
(2021) · Indian Journal of Continuing Nursing Education · doi:10.4103/2230-7354.320831 · Cited by 855
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Protein adsorption in three dimensions
Vogler, E. A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.059 · Cited by 585
Self-citationThe pathology of the foreign body reaction against biomaterials
Klopfleisch, R., & Jung, F. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35958 · Cited by 524
The contact activation and kallikrein/kinin systems: pathophysiologic and physiologic activities
Schmaier, A. H. (2016) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13194 · Cited by 396
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Self-citationTallawi, M., Rosellini, E., Barbani, N., Cascone, M. G., Rai, R., Saint-Pierre, G., & Boccaccini, A. R. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2015.0254 · Cited by 366
Interferences from blood collection tube components on clinical chemistry assays
Bowen, R. A. R., & Remaley, A. T. (2014) · Biochemia Medica · doi:10.11613/bm.2014.006 · Cited by 316
Martínez-Gutierrez, F., Thi, E. P., Silverman, J. M., de Oliveira, C. C., Svensson, S. L., Hoek, A. V., Sánchez, E. M., Reiner, N. E., Gaynor, E. C., Pryzdial, E. L. G., et al. (2012) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2011.06.014 · Cited by 286
Blood coagulation on biomaterials requires the combination of distinct activation processes
Sperling, C., Fischer, M., Maitz, M. F., & Werner, C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.044 · Cited by 281
Yang, Z., Wang, J., Luo, R., Maitz, M. F., Jing, F., Sun, H., & Huang, N. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.091 · Cited by 215
Central venous catheter-related thrombosis in children and adults
Citla Sridhar, D., Abou-Ismail, M. Y., & Ahuja, S. P. (2020) · Thrombosis Research · doi:10.1016/j.thromres.2020.01.017 · Cited by 200
Surface-grafted polysarcosine as a peptoid antifouling polymer brush
Lau, K. H. A., Ren, C., Sileika, T. S., Park, S. H., Szleifer, I., & Messersmith, P. B. (2012) · Langmuir · doi:10.1021/la302131n · Cited by 178
Yau, J. W., Liao, P., Fredenburgh, J. C., Stafford, A. R., Revenko, A. S., Monia, B. P., & Weitz, J. I. (2014) · Blood · doi:10.1182/blood-2013-12-540872 · Cited by 172
Ekdahl, K. N., Teramura, Y., Hamad, O. A., Asif, S., Duehrkop, C., Fromell, K., Gustafson, E., Hong, J., Kozarcanin, H., Magnusson, P. U., et al. (2016) · Immunological Reviews · doi:10.1111/imr.12471 · Cited by 160
Wang, J., He, Y., Maitz, M. F., Collins, B., Xiong, K., Guo, L., Yun, Y., Wan, G., & Huang, N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.02.041 · Cited by 160
“In the intrinsic or extrinsic pathways of the coagulation cascade, calcium ions are essential for the coagulation process [58].”
BackgroundEngineering biomaterials surfaces to modulate the host response
Yu, K., Mei, Y., Hadjesfandiari, N., & Kizhakkedathu, J. N. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.08.009 · Cited by 58
Crosslinking decreases the hemocompatibility of decellularized, porcine small intestinal submucosa
Glynn, J. J., Polsin, E. G., & Hinds, M. T. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.038 · Cited by 30
“contact activation pathway may play a more dominant role in biomaterial-mediated thrombosis, though this is controversial.[24,42] The PT and the APTT are two widely-used assays used to identify deficiencies of the extrinsic and intrinsic coagulation pathways, respectively.”
Method
Metadata
- Authors
- Vogler, E. A., & Siedlecki, C. A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 30
- Issue
- 10
- Pages
- 1857-1869
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2065722574
- Cited by
- 299
- References
- 72
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.