Triple-functional polyetheretherketone surface with enhanced bacteriostasis and anti-inflammatory and osseointegrative properties for implant application
The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Polyetheretherketone (PEEK) is considered a potential orthopedic/dental material because of its excellent mechanical and chemical properties (e.g., similar elastic modulus to that of human bone). However, the poor bacteriostasis and anti-inflammatory and osseointegrative properties of bioinert PEEK impede its clinical application. We previously developed a facile and versatile surface modification method using dexamethasone plus minocycline-loaded liposomes (Dex/Mino liposomes) bonded by a mussel-inspired polydopamine coating, which effectively modulated cell inflammatory response and discouraged bacterial colonization in vitro. Herein, we report the application of this multifunctional surface modification method to improve bioinert PEEK, aimed at further studying the in vitro osteogenesis and in vivo properties of Dex/Mino liposome-modified PEEK to prevent bacterial contamination, attenuate the inflammatory response, and enhance ossification for physiologic osseointegration. Our study established that the Dex/Mino liposome-modified PEEK surface presented favorable stability and cytocompatibility. Compared with bare PEEK, improved osteogenic differentiation of human mesenchymal stem cells under both osteoinductive and osteoconductive conditions was found on the functionalized surface due to the liposomal Dex releasing. In vivo bacteriostasis assay confirmed that Mino released from the functionalized surface provided an effective antibacterial effect. Moreover, the subcutaneous foreign body reaction and beagle femur implantation models corroborated the enhanced anti-inflammatory and osteointegrative properties of the functionalized PEEK. Our findings indicate that the developed Dex/Mino liposome-modified PEEK with enhanced antibacterial, anti-inflammatory, and osseointegrative capacity has great potential as an orthopedic/dental implant material for clinical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mussel-inspired surface chemistry for multifunctional coatings
Lee, H., Dellatore, S. M., Miller, W. M., & Messersmith, P. B. (2007) · Science · doi:10.1126/science.1147241 · Cited by 10,965
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Upon implantation, implants can evoke foreign body response at the implant–tissue interface, which is characterized by infiltration of numerous inflammatory cells and, eventually, encapsulation of the implants by dense fibrotic tissue, leading to failure of the implants [20,21].”
BackgroundChopra, I., & Roberts, M. (2001) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.65.2.232-260.2001 · Cited by 4,517 · cited 1×
“The mechanism by which Mino may block bacterial peptide and ribosomal protein synthesis can be summarized as breaking the association of aminoacyl-tRNA and bacterial ribosome by combining to form a specific ribosomal subunit, thereby disintegrating bacterial cells [58].”
BackgroundBiomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
Osteoinduction, osteoconduction and osseointegration
T., A., & C., J. (2001) · European Spine Journal · doi:10.1007/s005860100282 · Cited by 1,751 · cited 1×
“Osseointegration is a process involving the formation of a direct bone-to-implant contact without intervening fibrous connective tissue, providing an ordered and persistent functional connection for the implantation [12].”
BackgroundMinocycline: Far beyond an Antibiotic
Garrido‐Mesa, N., Zarzuelo, A., & Gálvez, J. (2013) · British Journal of Pharmacology · doi:10.1111/bph.12139 · Cited by 935
Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
Najeeb, S., Zafar, M. S., Khurshid, Z., & Siddiqui, F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2015.10.001 · Cited by 897
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
Biomaterial-Associated Infection: Locating the Finish Line in the Race for the Surface
Busscher, H. J., van der Mei, H. C., Subbiahdoss, G., Jutte, P. C., van den Dungen, J. J. A. M., Zaat, S. A. J., Schultz, M. J., & Grainger, D. W. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004528 · Cited by 707
Langenbach, F., & Handschel, J. (2013) · Stem Cell Research & Therapy · doi:10.1186/scrt328 · Cited by 662 · cited 1×
“As expected, the hMSCs cultured on the Dex/Mino lipo (−) group after 3 and 7 days expressed stronger ALP activity than the cells cultured on the blank lipo (−) group due to the presence of Dex (which is well-known for inducing osteogenic differentiation [47]) released from the Dex/Mino liposome-decorated surfaces.”
Background
Cited by
Bioinspired surface modification of orthopedic implants for bone tissue engineering
Hu, C., Ashok, D., Nisbet, D. R., & Gautam, V. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119366 · Cited by 324
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Antibacterial coatings on orthopedic implants
Chen, X., Zhou, J., Qian, Y., & Zhao, L. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100586 · Cited by 246
Fan, L., Guan, P., Xiao, C., Wen, H., Wang, Q., Liu, C., Luo, Y., Ma, L., Tan, G., Yu, P., et al. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.02.005 · Cited by 152
“After etching using concentrated sulfuric acid, a 3D porous structure was constructed on the PEEK surface which is not only favorable for Exos loading and delivery but also beneficial for improving osseointegration [17,19].”
BackgroundMethodBiomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Recent Development and Applications of Polydopamine in Tissue Repair and Regeneration Biomaterials
Guo, K., Wang, Y., Feng, Z.-X., Lin, X.-Y., Wu, Z.-R., Zhong, X.-C., Zhuang, Z.-M., Zhang, T., Chen, J., & Tan, W.-Q. (2024) · International Journal of Nanomedicine · doi:10.2147/ijn.s437854 · Cited by 41
Metadata
- Authors
- Xu, X., Li, Y., Wang, L., Li, Y., Pan, J., Fu, X., Luo, Z., Sui, Y., Zhang, S., Wang, L., Ni, Y., Zhang, L., & Wei, S.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 212
- Pages
- 98-114
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2944572535
- Cited by
- 195
- References
- 64
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.