A virus-induced kidney disease model based on organ-on-a-chip: Pathogenesis exploration of virus-related renal dysfunctions
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Renal dysfunctions usually happen in viral infections and many viruses specially infect distal renal tubules, however the pathogenesis remains unknown. Here, in order to explore the pathogenesis of virus-related renal dysfunctions, a Pseudorabies Virus (PrV) induced kidney disease model was built on a distal tubule-on-a-chip (DTC), for the first time. The barrier structure and Na reabsorption of distal renal tubules were successfully reconstituted in DTCs. After PrV infection, results showed electrolyte regulation dysfunction in Na reabsorption for the disordered Na transporters, the broken reabsorption barrier, and the transformed microvilli. And it would lead to virus induced serum electrolyte abnormalities. This work brought us a new cognition about the advantages of organ-on-a-chip (OOC) in virus research, for it had given us a better insight into the pathogenesis of virus induced dysfunctions, based on its unique ability in function reproduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Engineered In Vitro Disease Models
Benam, K. H., Dauth, S., Hassell, B., Herland, A., Jain, A., Jang, K.-J., Karalis, K., Kim, H. J., MacQueen, L., Mahmoodian, R., et al. (2015) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-012414-040418 · Cited by 554
Synergistic Engineering: Organoids Meet Organs-on-a-Chip
Takebe, T., Zhang, B., & Radisic, M. (2017) · Cell Stem Cell · doi:10.1016/j.stem.2017.08.016 · Cited by 258
3D microfluidic liver cultures as a physiological preclinical tool for hepatitis B virus infection
Ortega-Prieto, A. M., Skelton, J. K., Wai, S. N., Large, E., Lussignol, M., Vizcay-Barrena, G., Hughes, D., Fleck, R. A., Thursz, M., Catanese, M. T., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02969-8 · Cited by 236
Favoreel, H. W., Van Minnebruggen, G., Adriaensen, D., & Nauwynck, H. J. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409099102 · Cited by 159
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Ingber, D. E. (2020) · Advanced Science · doi:10.1002/advs.202002030 · Cited by 277
Integrating organoids and organ-on-a-chip devices
Zhao, Y., Landau, S., Okhovatian, S., Liu, C., Lu, R. X. Z., Lai, B. F. L., Wu, Q., Kieda, J., Cheung, K., Rajasekar, S., et al. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00207-z · Cited by 185
“Proximal tubule or glomerulus have been engineered separately by spatially arranging the primary or (conditionally) immortalized tubular epithelial cells or podocytes in OoC devices to resemble their native configurations with respect to endothelial cells 61–66 .”
Dufva, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-35043-5 · Cited by 14
Baddal, B. (2022) · Cyprus Journal of Medical Sciences · doi:10.4274/cjms.2020.1426 · Cited by 6
“In a first-time study, Wang et al.(48) has built a distal tubuleon-a-chip to explore the pathogenesis of pseudorabies virus induced kidney disease, which demonstrated that the virus infection induced renal dysfunction in electrolyte regulation and disorder of Na transporters due to disrupted tight junctions and intert…”
Metadata
- Authors
- Wang, J., Wang, C., Xu, N., Liu, Z.-F., Pang, D.-W., & Zhang, Z.-L.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 219
- Pages
- 119367
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2959622527
- Cited by
- 88
- References
- 8
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.