Evolution of metallic cardiovascular stent materials: A comparative study among stainless steel, magnesium and zinc
Open accessThe DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Abstract
A cardiovascular stent is a small mesh tube that expands a narrowed or blocked coronary artery. Unfortunately, current stents, regardless metallic or polymeric, still largely fall short to the ideal clinical needs due to late restenosis, thrombosis and other clinical complications. Nonetheless, metallic stents are preferred clinically thanks to their superior mechanical property and radiopacity to their polymeric counterparts. The emergence of bioresorbable metals opens a window for better stent materials as they may have the potential to reduce or eliminate late restenosis and thrombosis. In fact, some bioresorbable magnesium (Mg)-based stents have obtained regulatory approval or under trials with mixed clinical outcomes. Some major issues with Mg include the too rapid degradation rate and late restenosis. To mitigate these problems, bioresorbable zinc (Zn)-based stent materials are being developed lately with the more suitable degradation rate and better biocompatibility. The past decades have witnessed the unprecedented evolution of metallic stent materials from first generation represented by stainless steel (SS), to second generation represented by Mg, and to third generation represented by Zn. To further elucidate their pros and cons as metallic stent materials, we systematically evaluated their performances in vitro and in vivo through direct side-by-side comparisons. Our results demonstrated that tailored Zn-based material with proper configurations could be a promising candidate for a better stent material in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Global, Regional, and National Burden of Cardiovascular Diseases for 10 Causes, 1990 to 2015
Roth, G. A., Johnson, C., Abajobir, A., Abd-Allah, F., Abera, S. F., Abyu, G., Ahmed, M., Aksut, B., Alam, T., Alam, K., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.04.052 · Cited by 3,791
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Self-citationChen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398 · cited 3×
“In addition to the static mechanical strength and durability, cyclic fatigue strength and durability are also critical to the stent's stability in the pulsatile conditions [4].”
BackgroundWang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121 · cited 1×
“Higher corrosion resistance has been pursued for a long period for traditional inert metals and thus the titanium alloys, SS, and cobaltchrome alloys with excellent corrosion resistance have been developed rapidly and commercialized as permanent implant materials in many clinic applications [4,79,80].”
BackgroundDegradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343 · cited 1×
“The hemolysis tests and platelet adhesion tests were performed according to the method described previously [41,42].”
MethodSelf-citationBiomedical coatings on magnesium alloys – A review
Hornberger, H., Virtanen, S., & Boccaccini, A. R. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.012 · Cited by 1,273
Aligned biodegradable nanofibrous structure: a potential scaffold for blood vessel engineering
Xu, C. Y., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00593-3 · Cited by 1,213
Cited by
Chen, L.-Y., Liang, S.-X., Liu, Y., & Zhang, L.-C. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100648 · Cited by 603
Improving biocompatibility for next generation of metallic implants
Bandyopadhyay, A., Mitra, I., Goodman, S. B., Kumar, M., & Bose, S. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101053 · Cited by 463
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Applications of Magnesium and Its Alloys: A Review
Tan, J., & Ramakrishna, S. (2021) · Applied Sciences · doi:10.3390/app11156861 · Cited by 350
Biodegradable magnesium‐based biomaterials: An overview of challenges and opportunities
Amukarimi, S., & Mozafari, M. (2021) · MedComm · doi:10.1002/mco2.59 · Cited by 258
Yang, N., Gong, F., Liu, B., Hao, Y., Chao, Y., Lei, H., Yang, X., Gong, Y., Wang, X., Liu, Z., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29938-6 · Cited by 196
Functionalization treatment of micro-arc oxidation coatings on magnesium alloys: a review
Lin, Z., Wang, T., Yu, X., Sun, X., & Yang, H. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2021.160453 · Cited by 183
Advances in coatings on magnesium alloys for cardiovascular stents – A review
Zhang, Z.-Q., Yang, Y.-X., Li, J.-A., Zeng, R.-C., & Guan, S.-K. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.04.044 · Cited by 173
Lin, Z., Sun, X., & Yang, H. (2021) · Materials & Design · doi:10.1016/j.matdes.2020.109350 · Cited by 156
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Shen, X., Zhang, H., Li, X., Li, P., Zhao, Y., Wang, Y., & Wang, J. (2022) · Regenerative Biomaterials · doi:10.1093/rb/rbac068 · Cited by 21
Self-citationResearch progress on the role and mechanism of magnesium-containing materials in bone repair.
(2025) · PubMed Central · doi:10.12336/bmt.24.00038 · Cited by 3
Metadata
- Authors
- Fu, J., Su, Y., Qin, Y.-X., Zheng, Y., Wang, Y., & Zhu, D.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 230
- Pages
- 119641
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2991016599
- Cited by
- 209
- References
- 94
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.