Cited by 661Electrochemical sensors and biosensorsAnalytical Chemistry and SensorsElectrochemical Analysis and Applications

The DOI matches its Crossref record; 170 of the 174 references it cites were found in a registry or an index.

Biosensors for real-time in vivo measurements

Wilson, George S., Gifford, Raeann·2005·Biosensors and Bioelectronics

Abstract

The current status of sensors capable of continuous measurement of analytes in biological media is reviewed. This review containing 173 references deals with devices whose use in single cells, tissue slices, animal models and humans has been demonstrated. In addition to sensors specific for glucose, lactate, glutamate, pyruvate, choline and acetylcholine, insights obtained from monitoring nitric oxide, Na(+), K(+), Ca(2+), and dopamine are presented. Performance criteria for sensor performance are described as is the subject of biosensor calibration. Biocompatibility issues are dealt with in some detail as is the status of continuous blood glucose monitoring in humans.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.bios.2004.12.003

Cites

170 of 170 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 174 references

4 of the 174 references couldn’t be matched to a known paper.

Research works printed but not linked: 4

  1. Clark, 1998, Electrochemistry in neuronal microenvironments, Electroanal. Chem., 20, 227
  2. Ishihara, 1997, Preventing the protein adsorption by the phospholipid polymers, Polym. Mater. Sci. Eng., 77, 574
  3. Reichert, 1999, vol. 28
  4. Sharkawy, 1998, Engineering the tissue which encapsulates subcutaneous implants. Part III. Effective tissue response times, J. Biomed. Mater. Res., 40, 598, 10.1002/(SICI)1097-4636(19980615)40:4<598::AID-JBM11>3.0.CO;2-C · DOI

Cited by

Sorted by citations

Items 401–500 of 661

Metadata

Authors
Wilson, G. S., & Gifford, R.
Affiliations
University of Kansas (US)
Corresponding author
Wilson, George S.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2005-06
Volume
20
Issue
12
Pages
2388-2403
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2090868198
Cited by
660
References
174
Citations by year
2026: 17 · 2025: 21 · 2024: 14 · 2023: 16 · 2022: 17 · 2021: 13 · 2020: 23 · 2019: 27 · 2018: 36 · 2017: 25 · 2016: 37 · 2015: 39 · 2014: 40 · 2013: 50 · 2012: 52
FWCI
2.85
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
biosensors, in vivo monitoring, glucose sensor, lactate sensor, glutamate sensor, nitric oxide sensor, ion sensors, dopamine sensor, sensor calibration, biocompatibility, continuous glucose monitoring
MeSH terms
Blood Glucose, Equipment Design, Transducers, Blood Glucose Self-Monitoring, Biosensing Techniques, Monitoring, Ambulatory, Cell Culture Techniques, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review