The DOI matches its Crossref record; 170 of the 174 references it cites were found in a registry or an index.
Biosensors for real-time in vivo measurements
Abstract
The current status of sensors capable of continuous measurement of analytes in biological media is reviewed. This review containing 173 references deals with devices whose use in single cells, tissue slices, animal models and humans has been demonstrated. In addition to sensors specific for glucose, lactate, glutamate, pyruvate, choline and acetylcholine, insights obtained from monitoring nitric oxide, Na(+), K(+), Ca(2+), and dopamine are presented. Performance criteria for sensor performance are described as is the subject of biosensor calibration. Biocompatibility issues are dealt with in some detail as is the status of continuous blood glucose monitoring in humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As described earlier, the use of mediators to shuttle electrons between the enzyme and the electrode can also minimize the impact of interfering species by lowering the working potential required to oxidize hydrogen peroxide.56,58,62”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [58]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
HEPATOCELLULAR CARCINOMA AND HEPATITIS B VIRUS
Beasley, R. P., Lin, C., Hwang, L., & Chien, C. (1981) · The Lancet · doi:10.1016/s0140-6736(81)90585-7 · Cited by 2,856
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,858
Self-citationEvaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Neural activity triggers neuronal oxidative metabolism followed by astrocytic glycolysis
Kasischke, K. A., Vishwasrao, H. D., Fisher, P. J., Zipfel, W. R., & Webb, W. W. (2004) · Science · doi:10.1126/science.1096485 · Cited by 742
Surveying for Surfaces that Resist the Adsorption of Proteins
Chapman, R., Ostuni, E., Takayama, S., Holmlin, R. E., Yan, L., & Whitesides, G. M. (2000) · Journal of the American Chemical Society · doi:10.1021/ja000774f · Cited by 600
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
The Encyclopedia of Electrochemistry
(1965) · Students Quarterly Journal · doi:10.1049/sqj.1965.0065 · Cited by 501
Daunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith‐Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 446
Flagged first, then by citations
4 of the 174 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- Clark, 1998, Electrochemistry in neuronal microenvironments, Electroanal. Chem., 20, 227
- Ishihara, 1997, Preventing the protein adsorption by the phospholipid polymers, Polym. Mater. Sci. Eng., 77, 574
- Reichert, 1999, vol. 28
- Sharkawy, 1998, Engineering the tissue which encapsulates subcutaneous implants. Part III. Effective tissue response times, J. Biomed. Mater. Res., 40, 598, 10.1002/(SICI)1097-4636(19980615)40:4<598::AID-JBM11>3.0.CO;2-C · DOI
Cited by
Sorted by citations
Items 401–500 of 661
In vitro monitoring of goat-blood glycemia with a microwave biosensor
Kim, S., Kim, J., Kim, K., Lee, J., Babajanyan, A., Friedman, B., & Lee, K. (2014) · Current Applied Physics · doi:10.1016/j.cap.2014.01.011 · Cited by 13
Jamesh, M.-I., Boxman, R. L., Nosworthy, N. J., Falconer, I. S., Chu, P. K.-H., Bilek, M., Kondyurin, A. V., Ganesan, R., & McKenzie, D. R. (2014) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2014.11.025 · Cited by 13
Kvist, P. H., & Jensen, H. E. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100520 · Cited by 13
Microdialysis sampling techniques applied to studies of the foreign body reaction
Sides, C. R., & Stenken, J. A. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.11.002 · Cited by 13
Fernandes, E., Ledo, A., & Barbosa, R. M. (2022) · Molecules · doi:10.3390/molecules27020514 · Cited by 13
Biosensors for Foodborne Pathogen Detection
Warriner, K., & Namvar, A. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-088504-9.00322-6 · Cited by 13
Use of Enzymatic Biosensors to Quantify Endogenous ATP or H2O2 in the Kidney
Palygin, O., Levchenko, V., Evans, L. C., Blass, G., Cowley, A. W., & Staruschenko, A. (2015) · Journal of Visualized Experiments · doi:10.3791/53059 · Cited by 13
Needle-implantable, wireless biosensor for continuous glucose monitoring
Vaddiraju, S., Kastellorizios, M., Legassey, A., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299421 · Cited by 13
Rahman, A. R. A., Justin, G. A., & Guiseppi‐Elie, A. (2009) · Electroanalysis · doi:10.1002/elan.200804540 · Cited by 13
Lab automation in cultivation of adherent cells
Kuncová-Kallio, J., & Kallio, P. J. (2006) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2006.871482 · Cited by 13
Nanomaterial-based biosensors for food contaminant assessment
Dominguez, R. B., Hayat, A., Alonso-Silverio, G. A., Gutiérrez, J. M., Muñoz, R., & Marty, J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804301-1.00019-9 · Cited by 13
Electrochemical Sensor Designs for Biomedical Implants
Anastasova, S., Kassanos, P., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_2 · Cited by 13
Calibration of The Continuous Glucose Monitoring System for Transient Glucose Monitoring
Lesperance, L. M., Spektor, A. C., & McLeod, K. J. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0008 · Cited by 13
Takase, M., Takahashi, E., Murata, M., Ohnuki, H., Hibi, K., Ren, H., & Endo, H. (2012) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2011.649739 · Cited by 13
Chemically modified flexible strips as electrochemical biosensors
Raju, T., & Ganesh, V. (2014) · The Analyst · doi:10.1039/c4an00646a · Cited by 13
Diamond Microelectrodes and their Applications in Biological Studies
Martínez-Huitle, C. A. (2007) · Small · doi:10.1002/smll.200700272 · Cited by 13
Murack, M., Kadamani, A. K., Guindon-Riopel, A., Traynor, O. H., Iqbal, U., Bronner, S., Messier, C., & Ismail, N. (2024) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2024.107146 · Cited by 12
Wu, C., Alam, M. J., Qiu, S., Akter, S., Hong, S.-L., Islam, K. N., Liu, H., & Mahmud, S. (2025) · Diamond and Related Materials · doi:10.1016/j.diamond.2025.112263 · Cited by 12
Nanostructured glucose-oxidase immobilized SnO2 thin films for glucose sensing
Dhobale, S., Joshee, P., Deore, G. B., Laware, S. L., & Kale, S. N. (2011) · Applied Physics Letters · doi:10.1063/1.3555460 · Cited by 12
Unruh, R. M., Bornhoeft, L. R., Nichols, S. P., Wisniewski, N. A., & McShane, M. J. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202100380 · Cited by 12
Zhang, S., Huang, T., Bridgman, R. C., & Weese, J. O. (2006) · Journal of Food Science · doi:10.1111/j.1365-2621.2006.tb15631.x · Cited by 12
Adams, S. D., Kouzani, A. Z., Tye, S. J., Bennet, K. E., & Berk, M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0349-z · Cited by 12
Evans, G. W. H., Bhuiyan, W. T., Pang, S., Warren, B., Makris, K., Coleman, S., Hassan, S.-U., & Niu, X. (2021) · The Analyst · doi:10.1039/d1an00671a · Cited by 12
Electrochemical Biosensors for Real-Time Monitoring of Reactive Oxygen and Nitrogen Species
Liu, X., Dumitrescu, E., & Andreescu, S. (2015) · ACS symposium series · doi:10.1021/bk-2015-1200.ch013 · Cited by 12
Bioinformatics and enzymatics investigation of Trametes laccase for optical biosensing application
Wang, Y., & Chen, Z. (2018) · Journal of Materials Science · doi:10.1007/s10853-018-03187-9 · Cited by 12
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12
Alkasem, O., & Can, M. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.116030 · Cited by 11
Liao, S., Shiau, K.-Y., Wang, F.-H., & Yang, C. (2023) · Sensors · doi:10.3390/s23198029 · Cited by 11
Opening windows on new biology and disease mechanisms: development of real-time in vivo sensors
Eckert, M. A., & Zhao, W. (2013) · Interface Focus · doi:10.1098/rsfs.2013.0014 · Cited by 11
Electrical and Physical Sensors for Biomedical Implants
Kassanos, P., Anastasova, S., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_3 · Cited by 11
Activation‐Based Catalase Enzyme Electrode and its Usage for Glucose Determination
Akbayirli, P., & Akyılmaz, E. (2007) · Analytical Letters · doi:10.1080/00032710701689073 · Cited by 11
Conducting polymer nanofiber-based biosensor for detection of neurochemicals
Layton, K. N., & Abidian, M. R. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910546 · Cited by 11
Nanopatterned Surfaces for Bio-Detection
Lisboa, P., Valsesia, A., Colpo, P., Rossi, F., & Mascini, M. (2010) · Analytical Letters · doi:10.1080/00032711003653916 · Cited by 11
Hydrogen Peroxide Producing and Decomposing Enzymes: their Use in Biosensors and other Applications
Adányi, N., Barna, T., Emri, T., Miskei, M., & Pócsi, I. (2007) · Springer eBooks · doi:10.1007/1-4020-5377-0_25 · Cited by 11
Addressing Medical Device Challenges with Drug–Device Combinations
Avula, M., & Grainger, D. W. (2015) · Wiley eBooks · doi:10.1002/9781119002956.ch01 · Cited by 11
Ho, K. K. Y., Peng, Y.-W., Ye, M., Tchouta, L., Schneider, B., Hayes, M., Toomasian, J. M., Cornell, M. S., Rojas-Peña, Á., Charpie, J. R., et al. (2020) · Chemosensors · doi:10.3390/chemosensors8030056 · Cited by 10
Kassem, S. H., Hamdy, M. E., Selim, K. M., Elmasry, D., Shahein, M. A., & El-Husseini, D. M. (2024) · Molecules · doi:10.3390/molecules29071676 · Cited by 10
Lochead, J., Schessner, J. P., Werner, T., & Wölfl, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0131233 · Cited by 10
Kimmel, D. W., Meschievitz, M. E., Hiatt, L. A., & Cliffel, D. E. (2013) · Electroanalysis · doi:10.1002/elan.201300121 · Cited by 10
Animal Study and Pre-clinical Trials of Biomaterials
Noviana, D., Estuningsih, S., & Ulum, M. F. (2016) · Advanced structured materials · doi:10.1007/978-3-319-14845-8_4 · Cited by 10
Microelectrode Array Fabrication and Optimization for Selective Neurochemical Detection
Hascup, K. N., Hascup, E. R., Littrell, O. M., Hinzman, J. M., Werner, C. E., Davis, V. A., Burmeister, J. J., Pomerleau, F., Quintero, J. E., Huettl, P. F., et al. (2013) · Neuromethods · doi:10.1007/978-1-62703-370-1_2 · Cited by 10
Hughes, L. B., Labban, N., Conway, G. E., Pollock, J. A., & Leopold, M. C. (2019) · Sensors · doi:10.3390/s19112584 · Cited by 10
Self-Immobilized Putrescine Oxidase Biocatalyst System Engineered with a Metal Binding Peptide
Kamathewatta, N. J. B., Deay, D. O., Karaca, B. T., Seibold, S. A., Nguyen, T. M., Tomás, B., Richter, M. L., Berrie, C. L., & Tamerler, C. (2020) · Langmuir · doi:10.1021/acs.langmuir.0c01986 · Cited by 10
Laser-Induced Forward Transfer: A Laser-Based Technique for Biomolecules Printing
Serra, P., Duocastella, M., Fernández-Pradas, J. M., & Morenza, J. L. (2010) · Springer eBooks · doi:10.1007/978-90-481-9145-1_4 · Cited by 10
Thermomicrocapillaries as temperature biosensors in single cells
Herth, S., Giesguth, M., Wedel, W., Reiss, G., & Dietz, K. (2013) · Applied Physics Letters · doi:10.1063/1.4795289 · Cited by 10
Reconstitution of apoglucose oxidase with FAD conjugates for biosensoring of progesterone
Posthuma‐Trumpie, G. A., van den Berg, W., van de Wiel, D. F. M., Schaaper, W. M. M., Korf, J., & van Berkel, W. J. H. (2007) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2007.04.009 · Cited by 10
Automated Blood Sampling and Glucose Sensing in Critical Care Settings
Kunjan, K., & Lloyd, F. P. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200204 · Cited by 10
Sensor Embodiment and Flexible Electronics
Kassanos, P., Anastasova, S., Chen, C. M., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_4 · Cited by 11
Sensor and biosensor to detect vascular graft infection: diagnosis and challenges
Jamal, M., Shaikh, F. M., Aslam, B., & Razeeb, K. M. (2012) · Analytical Methods · doi:10.1039/c2ay25027f · Cited by 10
Stabilised Biosensing Using Needle‐Based Recess Electrodes
Anastasova, S., Spehar‐Délèze, A., Bickham, D., Uebel, P., Schmidt, M. A., Russell, P. S. J., & Vadgama, P. M. (2011) · Electroanalysis · doi:10.1002/elan.201100511 · Cited by 9
Zhang, Z., Hao, J., Xiao, T., Yu, P., & Mao, L. (2015) · The Analyst · doi:10.1039/c5an00593k · Cited by 9
CMOS biosensor devices and applications
Reed, M. A. (2013) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2013.6724587 · Cited by 9
Disposable amperometric biosensor based on nanostructured bacteriophages for glucose detection
Kang, Y. R., Hwang, K. H., Kim, J. H., Nam, C. H., & Kim, S. W. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/105804 · Cited by 9
Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry
Attar, T., Harek, Y., & Larabi, L. (2013) · Journal of the Korean Chemical Society · doi:10.5012/jkcs.2013.57.5.568 · Cited by 9
Development of a piezoelectric immunosensor for matrix metalloproteinase-1 detection
Soumetz, F. C., Pastorino, L., & Ruggiero, C. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333860 · Cited by 9
Functional Nanoparticle-Based Bioelectronic Devices
Hepel, T. (2012) · ACS symposium series · doi:10.1021/bk-2012-1113.ch008 · Cited by 9
Townsend, A. D., Sprague, R. S., & Martin, R. S. (2019) · Electroanalysis · doi:10.1002/elan.201900157 · Cited by 9
Sadana, A., & Sadana, N. (2010) · Elsevier eBooks · doi:10.1016/b978-0-444-53262-6.00005-x · Cited by 9
An Electrochemical Non‐Enzymatic Glucose Sensor Based on Ultrathin PdAg Single‐Crystalline Nanowires
Xu, X., Lv, H., Sun, L., Song, P., Liu, B., & Chen, X. (2020) · ChemPlusChem · doi:10.1002/cplu.202000141 · Cited by 8
Saira, F., Razzaq, H., Mumtaz, M., Ahmad, S., Rafiq, M. A., Yaqub, A., Dilshad, N., Ihsan, A., & Hasan, M. M. U. (2020) · Karbala International Journal of Modern Science · doi:10.33640/2405-609x.1370 · Cited by 8
Clark, K. M., & Henry, C. S. (2021) · Electroanalysis · doi:10.1002/elan.202100446 · Cited by 8
divya, D. D., Dastidar, M. G., Mahapatra, S., Kumari, R., Dkhar, D. S., Roy, S., & Chandra, P. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108431 · Cited by 8
Design of poly(N‐acryloylglycine) materials for incorporation of microorganisms
Ringeard, J.-M., Griesmar, P., Caplain, E., Michiel, M., Serfaty, S., Huérou, J. Y. L., Marinkova, D., & Yotova, L. K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39242 · Cited by 8
Starrett, M. A., Nielsen, M., Smeenge, D. M., Romanowicz, G. E., & Frost, M. C. (2012) · Nitric Oxide · doi:10.1016/j.niox.2012.08.074 · Cited by 8
Towards a FRET-based immunosensor for continuous carbohydrate monitoring
Engström, H. A., Andersson, P. O., Gregorius, K., & Ohlson, S. (2008) · Journal of Immunological Methods · doi:10.1016/j.jim.2008.01.021 · Cited by 8
Convolutive reshaping as a way to simulate voltammetry at disk electrodes
Mahon, P. J. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.11.096 · Cited by 8
Electropolymerized layers as selective membranes in first generation uric acid biosensors
Chen, K., Conway, G. E., Hamilton, G. A., Trawick, M. L., & Leopold, M. C. (2016) · Journal of Applied Electrochemistry · doi:10.1007/s10800-016-0947-z · Cited by 8
Template Based Electrochemical Synthesis of Copper (Cu) Nanowires as CH2Cl2 Sensor
Gupta, J., Arya, S. K., Singh, A., Verma, S., Sharma, A., Singh, B., & Tomar, A. (2020) · Integrated ferroelectrics · doi:10.1080/10584587.2019.1674990 · Cited by 8
Flexible Glucose Sensor Using Biocompatible Polymers
Kudo, H., Sawada, T., Chu, M. X., Saito, T., Saito, H., Otsuka, K., Iwasaki, Y., & Mitsubayashi, K. (2006) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2007.355544 · Cited by 8
Multiplexed and continuous microfluidic sensors using dynamic complex droplets
Barua, B., Durkin, T. J., Beeley, I. M., Gadh, A., & Savagatrup, S. (2023) · Soft Matter · doi:10.1039/d3sm00074e · Cited by 7
Mitsubayashi, K. (2014) · International Conference on Simulation of Semiconductor Processes and Devices · doi:10.1109/sispad.2014.6931635 · Cited by 7
Extreme Physiological State: Development of Tissue Lactate Sensor
Spehar‐Délèze, A., Anastasova, S., Popplewell, J. F., & Vadgama, P. M. (2012) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2012.32 · Cited by 7
NON ENZYMATIC ELECTROCHEMICAL DETECTION OF GLUCOSE AT RICE STARCH-NANOPARTICLES MODIFIED ELECTRODE
Saha, M. (2013) · International Journal of Pharma and Bio Sciences · Cited by 7
Sol-gel technology in enzymatic electrochemical biosensors for clinical analysis
Preda, G., Bizerea, O., & Vlad-Oros, B. (2011) · InTech eBooks · doi:10.5772/19622 · Cited by 9
Gangwar, R. K., Dhumale, V. A., Date, K. S., Alegaonkar, P. S., Sharma, R. B., & Datar, S. S. (2016) · Materials Research Express · doi:10.1088/2053-1591/3/3/035008 · Cited by 7
Enrico, P., & Diana, M. (2017) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2017.00097 · Cited by 8
Sandberg, S. G., & Garris, P. A. (2010) · Frontiers in neuroscience · doi:10.1201/9781420007350-c3 · Cited by 7
Biocatalysts Immobilized in Ultrathin Ordered Films
Sołoducho, J., & Cabaj, J. (2010) · Sensors · doi:10.3390/s101110298 · Cited by 7
Cavitas Sensors (Soft Contact Lens Type Biosensor, Mouth-Guard Type Sensor, etc.) for Daily Medicine
Arakawa, T., & Mitsubayashi, K. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-47319-2_3 · Cited by 7
Béland-Millar, A., & Messier, C. (2018) · Behavioural Brain Research · doi:10.1016/j.bbr.2018.02.018 · Cited by 7
Aptamer-Mediated Nanobiosensing for Health Monitoring
Malinee, M., Kumar, A., Dhiman, A., & Sharma, T. K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815743-5.00008-1 · Cited by 7
Mou, X., & Stenken, J. A. (2006) · Analytical Chemistry · doi:10.1021/ac061124i · Cited by 7
Whitney, L. V., Abasi, S., Aggas, J. R., & Guiseppi‐Elie, A. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202300153 · Cited by 6
Chiu, H.-C., & Su, C. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c01036 · Cited by 6
A first step to develop quantum medicine: Radiometers, detectors, and biosensors
Chamkouri, H., Si, J., Chen, P., Niu, C., & Chen, L. (2024) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2024.100658 · Cited by 6
Activity of formaldehyde dehydrogenase on titanium dioxide films with different crystallinities
Nakamura, H., Kato, K., Masuda, Y., & Kato, K. (2014) · Applied Surface Science · doi:10.1016/j.apsusc.2014.12.027 · Cited by 6
Enjalbert, Q., Racaud, A., Lemoine, J., Redon, S., Ayhan, M. M., Andraud, C., Chambert, S., Bretonnière, Y., Loison, C., Antoine, R., et al. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp2099015 · Cited by 6
Amperometric Biosensors for Lactate, Alcohols, and Glycerol Assays in Clinical Diagnostics
Smutok, O. V., Galina, Dmytruk, K. V., Halyna, Марина, Andriy, Czesaw, Broda, D., Wolfgang, W., Gonchar, M. V., et al. (2011) · InTech eBooks · doi:10.5772/16643 · Cited by 6
van den Bosch, E. E. M., de Bont, N. H. M., Qiu, J. H., & Gelling, O. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700223 · Cited by 8
Winter, R. T., van den Berg, T., Colpa, D. I., van Bloois, E., & Fraaije, M. W. (2011) · ChemBioChem · doi:10.1002/cbic.201100639 · Cited by 6
Frost, M. C., Wolf, A. K., & Meyerhoff, M. E. (2013) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737302-00129 · Cited by 6
3.34 Biomaterials Challenges in Continuous Glucose Monitors In Vivo
Rao, A. N., Avula, M., & Grainger, D. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09314-0 · Cited by 7
Zheng, L., & Zhang, Y. (2021) · Springer eBooks · doi:10.1007/978-981-16-1037-0_25 · Cited by 6
Lundquist, J., Horstmann, B., Pestov, D., Özgür, Ü., Avrutin, V. S., & Topsakal, E. (2022) · Biosensors · doi:10.3390/bios12050358 · Cited by 6
Neurochemistry of Addiction: Monitoring Essential Neurotransmitters of Addiction
Sandberg, S. G., & Garris, P. A. (2010) · CRC Press/Taylor & Francis, Boca Raton (FL) eBooks · Cited by 6
Antimicrobial and Anti‐Inflammatory Intelligent Surfaces
Griesser, H. J., Hall, H., Jenkins, A. T. A., Griesser, S. S., & Vasilev, K. A. (2012) · Wiley eBooks · doi:10.1002/9781118181249.ch6 · Cited by 6
Continuous monitoring of biomolecular targets in vivo using DNA-based electrochemical sensors
Chamorro-García, A., Alfonsini, M., Caprioli, D., Parolo, C., & Idili, A. (2025) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2025.101765 · Cited by 5
Ghahramani, Y., Razavi, N., Tavakol, O., Gholami, M. D., Khandani, F., Khaksar, E., Khaksar, E., Derakhshan, M., Kalashgrani, M. Y., Karganroudi, S. S., et al. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.126398 · Cited by 6
Multiscale Engineering of Ion‐Conducting Gels for Sustainable Bioelectronic Systems
Kim, J. H., Choi, W. H., Kim, J. H., Park, Y., Yun, S., Kim, T., & Kim, D. H. (2025) · Small Methods · doi:10.1002/smtd.202501625 · Cited by 5
Enzyme-Free Self-Powered Glucose Sensing System
Baingane, A., & Slaughter, G. E. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589871 · Cited by 5
Metadata
- Authors
- Wilson, G. S., & Gifford, R.
- Affiliations
- University of Kansas (US)
- Corresponding author
- Wilson, George S.
- ORCID
- Wilson, George S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2005-06
- Volume
- 20
- Issue
- 12
- Pages
- 2388-2403
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2090868198
- Cited by
- 660
- References
- 174
- Citations by year
- 2026: 17 · 2025: 21 · 2024: 14 · 2023: 16 · 2022: 17 · 2021: 13 · 2020: 23 · 2019: 27 · 2018: 36 · 2017: 25 · 2016: 37 · 2015: 39 · 2014: 40 · 2013: 50 · 2012: 52
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- biosensors, in vivo monitoring, glucose sensor, lactate sensor, glutamate sensor, nitric oxide sensor, ion sensors, dopamine sensor, sensor calibration, biocompatibility, continuous glucose monitoring
- MeSH terms
- Blood Glucose, Equipment Design, Transducers, Blood Glucose Self-Monitoring, Biosensing Techniques, Monitoring, Ambulatory, Cell Culture Techniques, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review