The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Aptamer–MIP hybrid receptor for highly sensitive electrochemical detection of prostate specific antigen
Open accessAbstract
This study reports the design and evaluation of a new synthetic receptor sensor based on the amalgamation of biomolecular recognition elements and molecular imprinting to overcome some of the challenges faced by conventional protein imprinting. A thiolated DNA aptamer with established affinity for prostate specific antigen (PSA) was complexed with PSA prior to being immobilised on the surface of a gold electrode. Controlled electropolymerisation of dopamine around the complex served to both entrap the complex, holding the aptamer in, or near to, it's binding conformation, and to localise the PSA binding sites at the sensor surface. Following removal of PSA, it was proposed that the molecularly imprinted polymer (MIP) cavity would act synergistically with the embedded aptamer to form a hybrid receptor (apta-MIP), displaying recognition properties superior to that of aptamer alone. Electrochemical impedance spectroscopy (EIS) was used to evaluate subsequent rebinding of PSA to the apta-MIP surface. The apta-MIP sensor showed high sensitivity with a linear response from 100pg/ml to 100ng/ml of PSA and a limit of detection of 1pg/ml, which was three-fold higher than aptamer alone sensor for PSA. Furthermore, the sensor demonstrated low cross-reactivity with a homologous protein (human Kallikrein 2) and low response to human serum albumin (HSA), suggesting possible resilience to the non-specific binding of serum proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hsu, C. H., & Mansfeld, F. (2001) · Corrosion · doi:10.5006/1.3280607 · Cited by 2,099
Heidenreich, A., Bastian, P. J., Bellmunt, J., Bolla, M., Joniau, S., van der Kwast, T., Mason, M., Matveev, V., Wiegel, T., Zattoni, F., et al. (2014) · European Urology · doi:10.1016/j.eururo.2013.09.046 · Cited by 1,936
Heidenreich, A., Bastian, P. J., Bellmunt, J., Bolla, M., Joniau, S., van der Kwast, T., Mason, M., Matveev, V., Wiegel, T., Zattoni, F., et al. (2014) · European Urology · doi:10.1016/j.eururo.2013.11.002 · Cited by 1,341
Polydopamine—a nature-inspired polymer coating for biomedical science
Lynge, M. E., van der Westen, R., Postma, A., & Städler, B. (2011) · Nanoscale · doi:10.1039/c1nr10969c · Cited by 907
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Analytical Chemistry · doi:10.1021/ac060830g · Cited by 660
From 3D to 2D: A Review of the Molecular Imprinting of Proteins
Turner, N. W., Jeans, C. W., Brain, K. R., Allender, C. J., Hlady, V., & Britt, D. W. (2006) · Biotechnology Progress · doi:10.1002/bp060122g · Cited by 396
Self-citationElectrochemical sensors based on molecularly imprinted polymers
Blanco-López, M. C., Lobo-Castañón, M. J., Miranda-Ordieres, A. J., & Tuñón-Blanco, P. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00102-5 · Cited by 382
Screening for Prostate Cancer With the Prostate-Specific Antigen Test: A Review of Current Evidence
Hayes, J. H., & Barry, M. J. (2014) · JAMA · doi:10.1001/jama.2014.2085 · Cited by 361
Characterization of Dopamine−Melanin Growth on Silicon Oxide
Bernsmann, F., Ponche, A., Ringwald, C., Hemmerlé, J., Raya, J., Bechinger, B., Voegel, J.-C., Schaaf, P., & Ball, V. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp901188h · Cited by 348
Enhanced resistance of DNA nanostructures to enzymatic digestion
Keum, J.-W., & Bermudez, H. (2009) · Chemical Communications · doi:10.1039/b917661f · Cited by 305
Electropolymerized Molecularly Imprinted Polymers as Receptor Layers in Capacitive Chemical Sensors
Panasyuk, T. L., Mirsky, V. M., Piletsky, S. A., & Wolfbeis, O. S. (1999) · Analytical Chemistry · doi:10.1021/ac9903196 · Cited by 273
Aptamer-based biosensor arrays for detection and quantification of biological macromolecules
McCauley, T. G., Hamaguchi, N., & Stanton, M. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(03)00297-5 · Cited by 266
The pH-controlled nanoparticles size of polydopamine for anti-cancer drug delivery
Ho, C.-C., & Ding, S.-J. (2013) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-013-4994-2 · Cited by 228
Łuczak, T. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.03.052 · Cited by 210
Ball, V., Frari, D. D., Michel, M., Buehler, M. J., Toniazzo, V., Singh, M. K., Gracio, J. J. D. A., & Ruch, D. (2011) · BioNanoScience · doi:10.1007/s12668-011-0032-3 · Cited by 173
Savory, N., Abe, K., Sode, K., & Ikebukuro, K. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.057 · Cited by 167
Ionic binding, net charge, and Donnan effect of human serum albumin as a function of pH
Fogh‐Andersen, N., Bjerrum, P. J., & Siggaard‐Andersen, O. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.1.48 · Cited by 148
Liu, K., Wei, W., Zeng, J., Liu, X., & Gao, Y. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0489-z · Cited by 127
Väisänen, V., Peltola, M. T., Lilja, H. G., Nurmi, M. J., & Pettersson, K. S. I. (2006) · Analytical Chemistry · doi:10.1021/ac061201+ · Cited by 69
Kallikreins as Biomarkers for Prostate Cancer
Hong, S. K. (2014) · BioMed Research International · doi:10.1155/2014/526341 · Cited by 60
Polydopamine-assisted deposition of heparin for selective adsorption of low-density lipoprotein
Liu, Y., Qiu, W., Yang, H., Qian, Y., Huang, X., & Xu, Z. (2015) · RSC Advances · doi:10.1039/c4ra16700g · Cited by 26
Cited by
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Development of a portable MIP-based electrochemical sensor for detection of SARS-CoV-2 antigen
Raziq, A., Kidakova, A., Boroznjak, R., Reut, J., Öpik, A., & Syritski, V. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113029 · Cited by 454
Metadata
- Authors
- Jolly, P., Tamboli, V., Harniman, R. L., Estrela, P., Allender, C. J., & Bowen, J. L.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2016-01
- Volume
- 75
- Pages
- 188-195
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2153088547
- Cited by
- 286
- References
- 21
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.