The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A touch-actuated glucose sensor fully integrated with microneedle array and reverse iontophoresis for diabetes monitoring
Abstract
The development of non-invasive biosensor for monitoring glucose in interstitial fluid (ISF) is still challenging, because ISF extraction through classical reverse iontophoresis (RI) is limited by low extraction flux and consistency. Here, we developed a touch-actuated biosensor for monitoring glucose in ISF. The biosensor is composed of three main components: 1) the solid microneedle array (MA) for painless skin penetration; 2) the RI unit for ISF extraction through the MA-created microchannels; and 3) the sensing unit for glucose monitoring. The sensing strategy of this biosensor is "skin penetration-RI extraction-electrochemical detection". Compared with RI extraction only, the reported skin penetration-RI extraction sampling strategy obviously increased the glucose extraction flux by ∼1.6 times not only in vitro but also in vivo. Moreover, we developed a wearable glucose monitoring system by incorporating this touch-actuated biosensor, a wireless electrochemical detector, and a smartphone application. In vivo experiments using healthy and diabetic rats revealed a high correlation between the results measured by the reported wearable system and commercially blood glucometer. This sampling strategy which combined skin penetration and RI extraction paves the way to develop wearable platforms for not only glucose monitoring but also various ISF biomarkers without the need of painful finger-stick blood sampling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic kidney disease: global dimension and perspectives
Jha, V., Garcia-Garcia, G., Iseki, K., Li, Z., Naicker, S., Plattner, B., Saran, R., Wang, A. Y.-M., & Yang, C.-W. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60687-x · Cited by 4,383
Antonetti, D. A., Klein, R., & Gardner, T. W. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1005073 · Cited by 1,659
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315
Wearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Bisson, A., Bodin, A., Fauchier, G., Herbert, J., Angoulvant, D., Ducluzeau, P. H., Lip, G. Y. H., & Fauchier, L. (2021) · Cardiovascular Diabetology · doi:10.1186/s12933-021-01216-7 · Cited by 44
Cited by
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Metadata
- Authors
- Cheng, Y., Gong, X., Yang, J., Zheng, G., Zheng, Y., Li, Y., Xu, Y., Nie, G., Xie, X., Chen, M., Yi, C., & Jiang, L.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 203
- Pages
- 114026
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W4207018047
- Cited by
- 193
- References
- 9
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A touch-actuated glucose sensor fully integrated with microneedle array and reverse iontophoresis for diabetes monitoring. https://app.cochat.ai/papers/10.1016/j.bios.2022.114026
- The paper
- Cheng, Y., Gong, X., Yang, J., Zheng, G., Zheng, Y., Li, Y., Xu, Y., Nie, G., Xie, X., Chen, M., Yi, C., & Jiang, L. (2022). A touch-actuated glucose sensor fully integrated with microneedle array and reverse iontophoresis for diabetes monitoring. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2022.114026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.