The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
SERS-based CRISPR/Cas assay on microfluidic paper analytical devices for supersensitive detection of pathogenic bacteria in foods
Abstract
Rapid and point-of-need (PON) detection of bacteria is crucial to directly provide rapid and reliable diagnostics information during on-site tests, allowing more room for taking proactive measures. By taking the multifaceted advantages of CRISPR/Cas12a and surface-enhanced Raman scattering (SERS), for the first time, we designed a recombinase polymerase amplification (RPA)-integrated microfluidic paper-based analytical device (μPAD), coined RPA-Cas12a-μPAD for supersensitive SERS detection. Single-stranded DNAs were designed to "pull down" SERS nanoprobes. The amplicons of the invA gene triggered the trans-cleavage of Cas12a, resulting in the indiscriminate shredding of linker ssDNA. Thus, the degree of aggregation of SERS nanoprobes was dependent on the concentration of Salmonella typhimurium (S. typhi), which was determined on a μPAD and monitored by a Raman spectrometer. The limit of detection for S. typhi was approximately 3-4 CFU/mL for spiked milk and meat samples with a dynamic detection range from 1 to 108 CFU/mL. The RPA-Cas12a-μPAD secured accurate tests for food samples in 45 min. This work expands the reach of CRISPR-based diagnostics (CRISPR-Dx) and provides a novel and robust bacterial PON detection platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRISPR-Cas12a target binding unleashes indiscriminate single-stranded DNase activity
Chen, J. S., Ma, E., Harrington, L. B., Da Costa, M., Tian, X., Palefsky, J. M., & Doudna, J. A. (2018) · Science · doi:10.1126/science.aar6245 · Cited by 4,507
CRISPR–Cas12-based detection of SARS-CoV-2
Broughton, J. P., Deng, X., Yu, G., Fasching, C. L., Servellita, V., Singh, J., Miao, X., Streithorst, J. A., Granados, A., Sotomayor-Gonzalez, A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0513-4 · Cited by 2,717
Havelaar, A. H., Kirk, M. D., Torgerson, P. R., Gibb, H. J., Hald, T., Lake, R. J., Praet, N., Bellinger, D. C., de Silva, N. R., Gargouri, N., et al. (2015) · PLoS Medicine · doi:10.1371/journal.pmed.1001923 · Cited by 2,067
Kaminski, M. M., Abudayyeh, O. O., Gootenberg, J. S., Zhang, F., & Collins, J. J. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00760-7 · Cited by 1,259
CRISPR/Cas Systems towards Next-Generation Biosensing
Li, Y., Li, S., Wang, J., & Liu, G. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.12.005 · Cited by 917
Self-citationDai, Y., Somoza, R. A., Wang, L., Welter, J. F., Li, Y., Caplan, A. I., & Liu, C. C. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201910772 · Cited by 660
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
CRISPR-Cas12a-driven MXene-PEDOT:PSS piezoresistive wireless biosensor
Zeng, R., Wang, W., Chen, M., Wan, Q., Wang, C., Knopp, D., & Tang, D. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105711 · Cited by 394
Simultaneous Dual‐Gene Diagnosis of SARS‐CoV‐2 Based on CRISPR/Cas9‐Mediated Lateral Flow Assay
Xiong, E., Jiang, L., Tian, T., Hu, M., Yue, H., Huang, M., Lin, W., Jiang, Y., Zhu, D., & Zhou, X. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202014506 · Cited by 314
An ultrasensitive CRISPR/Cas12a based electrochemical biosensor for Listeria monocytogenes detection
Li, F., Ye, Q., Chen, M., Zhou, B., Zhang, J., Pang, R., Xue, L., Wang, J., Zeng, H., Wu, S., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113073 · Cited by 289
Self-citationCRISPR-Cas based virus detection: Recent advances and perspectives
Yin, L., Man, S., Ye, S., Liu, G., & Ma, L. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113541 · Cited by 277
Self-citationCRISPR Mediated Biosensing Toward Understanding Cellular Biology and Point‐of‐Care Diagnosis
Dai, Y., Wu, Y., Liu, G., & Gooding, J. J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202005398 · Cited by 242
Self-citationEmerging bacterial pathogens: the past and beyond
Vouga, M., & Greub, G. (2016) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2015.10.010 · Cited by 208
Ma, L., Peng, L., Yin, L., Liu, G., & Man, S. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00686 · Cited by 181
Self-citationNaked-Eye Detection of Grapevine Red-Blotch Viral Infection Using a Plasmonic CRISPR Cas12a Assay
Li, Y., Mansour, H., Wang, T., Poojari, S., & Li, F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03545 · Cited by 174
Tian, Y.-F., Ning, C.-F., He, F., Yin, B.-C., & Ye, B.-C. (2018) · The Analyst · doi:10.1039/c8an01041b · Cited by 172
Choi, J.-H., Shin, M., Yang, L., Conley, B., Yoon, J., Lee, S.-N., Lee, K.-B., & Choi, J.-W. (2021) · ACS Nano · doi:10.1021/acsnano.1c03975 · Cited by 165
A smartphone-based visual biosensor for CRISPR-Cas powered SARS-CoV-2 diagnostics
Ma, L., Yin, L., Li, X., Chen, S., Peng, L., Liu, G., Ye, S., Zhang, W., & Man, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113646 · Cited by 153
Self-citationPang, Y., Li, Q., Wang, C., zhen, S., Sun, Z., & Xiao, R. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132109 · Cited by 149
Chen, Y., Mei, Y., & Jiang, X. (2021) · Chemical Science · doi:10.1039/d0sc05717g · Cited by 144
CRISPR-Cas12a based aptasensor for sensitive and selective ATP detection
Peng, L., Zhou, J., Liu, G., Yin, L., Ren, S., Man, S., & Ma, L. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128164 · Cited by 134
Self-citationLiu, J., Chen, J., Wu, D., Huang, M., Chen, J., Pan, R., Wu, Y., & Li, G. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01163 · Cited by 107
SPRINT: a Cas13a-based platform for detection of small molecules
Iwasaki, R. S., & Batey, R. (2020) · Nucleic Acids Research · doi:10.1093/nar/gkaa673 · Cited by 99
Wang, D., Wang, J., Du, Y., Ma, J.-Y., Wang, S.-Y., Tang, A., & Kong, D. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112556 · Cited by 94
Self-citationCRISPR/Cas Powered Multiplexed Biosensing
Bruch, R. C., Urban, G. A., & Dincer, C. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2019.04.005 · Cited by 93
Liang, J., Teng, P., Xiao, W., He, G., Song, Q., Zhang, Y., Peng, B., Li, G., Hu, L., Cao, D., et al. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-021-01021-0 · Cited by 88
Peng, L., Zhou, J., Yin, L., Man, S., & Ma, L. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.05.017 · Cited by 79
Self-citationSERS Sensors: Recent Developments and a Generalized Classification Scheme Based on the Signal Origin
Gu, X., Trujillo, M. J., Olson, J. E., & Camden, J. P. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125724 · Cited by 76
trans Single‐Stranded DNA Cleavage via CRISPR/Cas14a1 Activated by Target RNA without Destruction
Wei, Y., Yang, Z., Zong, C., Wang, B., Ge, X., Tan, X., Liu, X., Tao, Z., Wang, P., Ma, C., et al. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202110384 · Cited by 72
Ghorbanizamani, F., Moulahoum, H., Zihnioğlu, F., Evran, S., Çiçek, C., Sertoz, R. Y., Arda, B., Göksel, T., Turhan, K., & Tımur, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113484 · Cited by 43
Metadata
- Authors
- Zhuang, J., Zhao, Z., Lian, K., Yin, L., Wang, J., Man, S., Liu, G., & Ma, L.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2022-07
- Volume
- 207
- Pages
- 114167
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W4220917387
- Cited by
- 295
- References
- 30
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.