Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893 · cited 1×
“2-mm region around the fracture callus [29].”
Self-citationProduction of a standard closed fracture in laboratory animal bone
Bonnarens, F., & Einhorn, T. A. (1984) · Journal of Orthopaedic Research · doi:10.1002/jor.1100020115 · Cited by 888 · cited 1×
“Male Sabra rats (Animal Quarters, Hebrew University Medical School; mean weight 295F 14 g) received a closed unilateral mid-diaphyseal femur fracture [5].”
Backgroundvan Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865 · cited 1×
“Previous studies have used finite element models derived from CT images to determine the mechanical properties of whole bones [8,12], fractured bones [33], trabecular bone [21,36], and osteoporotic bone [22].”
BackgroundOn the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734 · cited 1×
“Previous studies have suggested various relations between the bone density and the elastic modulus [7,27,30].”
BackgroundStiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652 · cited 1×
“Previous studies have suggested various relations between the bone density and the elastic modulus [7,27,30].”
BackgroundHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322 · cited 2×
“Previous studies have used structural parameters [22] or finite element models [14] of unfractured trabecular bone to predict bone stiffness and obtained correlation coefficients with experimental measurements from 0.”
BackgroundMethodTaddei, F., Pancanti, A., & Viceconti, M. (2004) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00138-3 · Cited by 274 · cited 1×
“Studies have examined the sensitivity of the model to material properties [6,32,34], image and mesh resolution [25], and element type [14,19].”
BackgroundThree-dimensional finite element modelling of non-invasively assessed trabecular bone structures
Müller, R., & Rüegsegger, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91884-j · Cited by 240 · cited 1×
“Previous studies have used finite element models derived from CT images to determine the mechanical properties of whole bones [8,12], fractured bones [33], trabecular bone [21,36], and osteoporotic bone [22].”
BackgroundSelf-citationNewitt, D. C., van Rietbergen, B., & Majumdar, S. (2002) · Osteoporosis International · doi:10.1007/s001980200027 · Cited by 199
Micro-tomographic imaging for the nondestructive evaluation of trabecular bone architecture.
Müller, R., & Ruegsegger, P. (1997) · PubMed · Cited by 197
Self-citationvan Rietbergen, B., Ingersleben, G. V., Chesnut, C. H., MacDonald, B. R., Genant, H. K., Newitt, D. C., Majumdar, S., Harris, S. T., & Garnero, P. (2002) · Osteoporosis International · doi:10.1007/s198-002-8332-0 · Cited by 179 · cited 2×
“Previous studies have used structural parameters [22] or finite element models [14] of unfractured trabecular bone to predict bone stiffness and obtained correlation coefficients with experimental measurements from 0.”
BackgroundMethodDavid, V., Laroche, N., Boudignon, B. M., Lafage‐Proust, M., Alexandre, C., Ruegsegger, P., & Vico, L. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.9.1622 · Cited by 169 · cited 1×
“Whereas experimental testing requires sacrifice of the animal, FEA can be performed on living animals with images obtained from an in vivo micro-CT scanner [10].”
MethodPanjabi, M. M., Walter, S. D., Karuda, M., White, A. A., & Lawson, J. P. (1985) · Journal of Orthopaedic Research · doi:10.1002/jor.1100030211 · Cited by 159 · cited 2×
“It was shown, however, that these measures do not sufficiently predict fracture strength [24].”
BackgroundTrabecular bone's mechanical properties are affected by its non-uniform mineral distribution
van der Linden, J. C., Birkenhäger-Frenkel, D. H., Verhaar, J. A. N., & Weinans, H. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00146-4 · Cited by 149
Bourne, B. C., & van der Meulen, M. C. H. (2003) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.10.002 · Cited by 138 · cited 2×
“3 was assigned for all elements [6].”
BackgroundMonitoring and healing analysis of 100 tibial shaft fractures
Claes, L., Grass, R., Schmickal, T., Kisse, B., Eggers, C., Gerngro�, H., Mutschler, W., Arand, M., Wintermeyer, T., & Wentzensen, A. (2002) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-002-0306-x · Cited by 137 · cited 1×
“Others have used external fixators to monitor the interfragmentary movement at the fracture ends [9,13,15,16,31] and to assess rigidity of the fracture [28,37].”
BackgroundSelf-citationQuantitative Assessment of Experimental Fracture Repair by Peripheral Computed Tomography
Augat, P., Merk, J., Genant, H. K., & Claes, L. (1997) · Calcified Tissue International · doi:10.1007/s002239900213 · Cited by 121 · cited 2×
“87 [2,18].”
MethodSelf-citationOsteogenic growth peptide modulates fracture callus structural and mechanical properties
Gabet, Y., Müller, R., Regev, E., Sela, J., Shteyer, A., Palomares, K. T. S., Chorev, M., & Bab, I. (2004) · Bone · doi:10.1016/j.bone.2004.03.025 · Cited by 111
Self-citationA three-dimensional finite element model from computed tomography data: A semi-automated method
Cattaneo, P. M., Dalstra, M., & Frich, L. H. (2001) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411011533760 · Cited by 108 · cited 1×
“Previous studies have used finite element models derived from CT images to determine the mechanical properties of whole bones [8,12], fractured bones [33], trabecular bone [21,36], and osteoporotic bone [22].”
Backgroundvan Rietbergen, B., Majumdar, S., Newitt, D. N., & MacDonald, B. R. (2002) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00110-3 · Cited by 89
X-Ray Diagnosis of Healing Fractures in Rabbits
NICHOLLS, P. J., BERG, E., BLIVEN, F. E., & KLING, J. M. (1979) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197907000-00037 · Cited by 64 · cited 1×
“Roentgenograms are evaluated using qualitative observations such as loss of fracture line and bony bridging of the fracture gap [23].”
Fracture stiffness measurement in the assessment and management of tibial fractures
Richardson, J., KENWRIGHT, J., & Cunningham, J. L. (1992) · Clinical Biomechanics · doi:10.1016/0268-0033(92)90018-y · Cited by 63 · cited 1×
“Others have used external fixators to monitor the interfragmentary movement at the fracture ends [9,13,15,16,31] and to assess rigidity of the fracture [28,37].”
BackgroundPerillo‐Marcone, A., Alonso-Vázquez, A., & Taylor, M. (2003) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/1025584031000064470 · Cited by 61 · cited 1×
“Studies have examined the sensitivity of the model to material properties [6,32,34], image and mesh resolution [25], and element type [14,19].”
BackgroundThree-dimensional load measurements in an external fixator
Seide, K., Weinrich, N., Wenzl, M. E., Wolter, D., & Jürgens, C. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.025 · Cited by 58
Mechanical strength of a femoral reconstruction in paediatric oncology: A finite element study
Taddei, F., Viceconti, M., Manfrini, M., & Toni, A. (2003) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544110360579321 · Cited by 46 · cited 1×
“Previous studies have used finite element models derived from CT images to determine the mechanical properties of whole bones [8,12], fractured bones [33], trabecular bone [21,36], and osteoporotic bone [22].”
Background
Cited by
Morgan, E. F., Mason, Z. D., Chien, K. B., Pfeiffer, A. J., Barnes, G. L., Einhorn, T. A., & Gerstenfeld, L. C. (2009) · Bone · doi:10.1016/j.bone.2008.10.039 · Cited by 266
Straumit, I., Lomov, S. V., & Wevers, M. (2015) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2014.11.016 · Cited by 242
A Perspective: Engineering Periosteum for Structural Bone Graft Healing
Zhang, X., Awad, H. A., O’Keefe, R. J., Guldberg, R. E., & Schwarz, E. M. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0312-6 · Cited by 234
Bone Formation During Distraction Osteogenesis Is Dependent on Both VEGFR1 and VEGFR2 Signaling
Jacobsen, K. A., Al-Aql, Z. S., Wan, C., Fitch, J. L., Stapleton, S. N., Mason, Z. D., Cole, R. M., Gilbert, S. R., Clemens, T. L., Morgan, E. F., et al. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080103 · Cited by 192
Application of Histomorphometric Methods to the Study of Bone Repair
Gerstenfeld, L. C., Wronski, T. J., Hollinger, J. O., & Einhorn, T. A. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050702 · Cited by 172
Metadata
- Authors
- Shefelbine, S. J., Simon, U., Claes, L., Gold, A., Gabet, Y., Bab, I., Müller, R., & Augat, P.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 2005-03
- Volume
- 36
- Issue
- 3
- Pages
- 480-488
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2046713908
- Cited by
- 179
- References
- 26
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.