Advances in Micropipette Aspiration: Applications in Cell Biomechanics, Models, and Extended Studies
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
With five decades of sustained application, micropipette aspiration has enabled a wide range of biomechanical studies in the field of cell mechanics. Here, we provide an update on the use of the technique, with a focus on recent developments in the analysis of the experiments, innovative microaspiration-based approaches, and applications in a broad variety of cell types. We first recapitulate experimental variations of the technique. We then discuss analysis models focusing on important limitations of widely used biomechanical models, which underpin the urge to adopt the appropriate ones to avoid misleading conclusions. The possibilities of performing different studies on the same cell are also considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423 · cited 4×
“A simple approach, suitable for some suspended cells and taking into account the actomyosin cortex contractility, is to consider the cell mechanically equivalent to a liquid drop, its shape being determined by the cortical tension Tc (38,50) produced by the actomyosin cortex (51).”
BackgroundInfluentialEntropy-driven tension and bending elasticity in condensed-fluid membranes
Evans, E., & Rawicz, W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.2094 · Cited by 1,128 · cited 1×
“7 is easily modified if the cortical tension is considered different inside and outside the pipette (52).”
BackgroundA Review of Cell Adhesion Studies for Biomedical and Biological Applications
Khalili, A., & Ahmad, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160818149 · Cited by 951
Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration
Evans, E., & Yeung, A. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82660-8 · Cited by 788
Universal physical responses to stretch in the living cell
Trepat, X., Deng, L., An, S. S., Navajas, D., Tschumperlin, D. J., Gerthoffer, W. T., Butler, J. P., & Fredberg, J. J. (2007) · Nature · doi:10.1038/nature05824 · Cited by 699 · cited 1×
“When a cell undergoes large deformations, it evolves from a solid-like to a fluid-like behavior (47,48), and it is possible to quantify its apparent viscosity (21,42).”
BackgroundThe cytoplasm of living cells behaves as a poroelastic material
Moeendarbary, E., Valon, L., Fritzsche, M., Harris, A. R., Moulding, D. A., Thrasher, A. J., Stride, E., Mahadevan, L., & Charras, G. T. (2013) · Nature Materials · doi:10.1038/nmat3517 · Cited by 686 · cited 2×
“In poroelastic (and poroviscoelastic) models, the cell is described as an elastic (or viscoelastic) porous structure dispersed in a viscous fluid (48,55).”
BackgroundCell Mechanics: Integrating Cell Responses to Mechanical Stimuli
Janmey, P. A., & McCulloch, C. A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151927 · Cited by 630
Mechanoreciprocity in cell migration
van Helvert, S., Storm, C., & Friedl, P. (2018) · Nature Cell Biology · doi:10.1038/s41556-017-0012-0 · Cited by 587
Viscoelastic Properties of the Cell Nucleus
Guilak, F., Tedrow, J. R., & Burgkart, R. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.2360 · Cited by 587 · cited 2×
“From the 1970s, microaspiration experiments have remained widely used in the study of cell mechanics, comprising assays of suspended cells—mainly blood cells (1,18–22)— and adherent cells—adhered cells or resuspended cells (5,23–27) —, cell nucleus (28), cell blebs (29), giant unilamellar vesicles (30–33), extracellul…”
BackgroundHouk, A. R., Jilkine, A., Mejean, C. O., Boltyanskiy, R., Dufresne, E. R., Angenent, S. B., Altschuler, S. J., Wu, L. F., & Weiner, O. D. (2012) · Cell · doi:10.1016/j.cell.2011.10.050 · Cited by 565 · cited 3×
“3 is (37): LpðtÞ Rp ¼ DP cl JðtÞ: (5) Regarding the creep function J(t), the standard linear solid model with three parameters and the power-law rheological model with two parameters are customarily used for aspiration experiments (45,46).”
BackgroundQuantifying forces in cell biology
Roca-Cusachs, P., Conte, V., & Trepat, X. (2017) · Nature Cell Biology · doi:10.1038/ncb3564 · Cited by 498
Measuring cell-generated forces: a guide to the available tools
Polacheck, W. J., & Chen, C. S. (2016) · Nature Methods · doi:10.1038/nmeth.3834 · Cited by 489
Evans, E. A. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86036-9 · Cited by 391
Theret, D. P., Levesque, M. J., Sato, M., Nerem, R. M., & Wheeler, L. T. (1988) · Journal of Biomechanical Engineering · doi:10.1115/1.3108430 · Cited by 382 · cited 2×
“(43) provided one equation to compute the elastic modulus E of a sample, assumed to be a homogeneous incompressible linear-elastic half space:”
BackgroundAsymmetric division of contractile domains couples cell positioning and fate specification
Maître, J.-L., Turlier, H., Illukkumbura, R., Eismann, B., Niwayama, R., Nédélec, F., & Hiiragi, T. (2016) · Nature · doi:10.1038/nature18958 · Cited by 381 · cited 1×
“The mechanical behavior of cells is central to the cell state and functions, including growth (1), degree of differentiation (2,3), ability to migrate (4,5), immune cell activation (6), and fate (7).”
BackgroundSato, M., Theret, D. P., Wheeler, L. T., Ohshima, N., & Nerem, R. M. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891183 · Cited by 373
Cortical shell-liquid core model for passive flow of liquid-like spherical cells into micropipets
Yeung, A., & Evans, E. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82659-1 · Cited by 289 · cited 1×
“When a cell undergoes large deformations, it evolves from a solid-like to a fluid-like behavior (47,48), and it is possible to quantify its apparent viscosity (21,42).”
BackgroundMolecular mechanisms of cellular mechanosensing
Luo, T., Mohan, K., Iglesias, P. A., & Robinson, D. N. (2013) · Nature Materials · doi:10.1038/nmat3772 · Cited by 267 · cited 2×
“Dynamic changes, heterogeneity, and anisotropy are not taken into account by these models and may contribute to the variability of the evaluated deformability parameters (for instance, because of a mechanosensing-related evolution of a nonhomogeneous cytoskeletal cortex) (49).”
BackgroundAlexopoulos, L. G., Haider, M. A., Vail, T. P., & Guilak, F. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1579047 · Cited by 221 · cited 2×
“From the 1970s, microaspiration experiments have remained widely used in the study of cell mechanics, comprising assays of suspended cells—mainly blood cells (1,18–22)— and adherent cells—adhered cells or resuspended cells (5,23–27) —, cell nucleus (28), cell blebs (29), giant unilamellar vesicles (30–33), extracellul…”
BackgroundMultiscale force sensing in development
Petridou, N. I., Spiró, Z., & Heisenberg, C.-P. (2017) · Nature Cell Biology · doi:10.1038/ncb3524 · Cited by 221
In vivo mechanical characterization of human liver
Nava, A., Mazza, E., Furrer, M., Villiger, P., & Reinhart, W. H. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.10.001 · Cited by 220
Review on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218 · cited 1×
“8 would reduce the differences between the elastic modulus estimated by aspiration and by other techniques usually yielding higher values (13).”
BackgroundShao, J. Y., & Hochmuth, R. M. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79486-9 · Cited by 193 · cited 2×
“Typically, Uf is several orders of magnitude higher than U (Uf z 4 mm/s for a capillary of internal radius Rp z 5 mm and for a low value rgh1⁄4 1 Pa (40)).”
BackgroundMethodThe physical chemistry of cytoplasm and its influence on cell function: an update
Luby-Phelps, K. (2013) · Molecular Biology of the Cell · doi:10.1091/mbc.e12-08-0617 · Cited by 191 · cited 1×
“The interior of the cell is a complex fluid with active microdomains that can be tuned by the cell to control its structure and function (53).”
BackgroundEvans, E., & Kukan, B. (1984) · Blood · doi:10.1182/blood.v64.5.1028.1028 · Cited by 188
Advances in high-throughput single-cell microtechnologies
Weaver, W. M., Tseng, P., Kunze, A., Masaeli, M., Chung, A. J., Dudani, J. S., Kittur, H., Kulkarni, R. P., & Carlo, D. D. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.09.005 · Cited by 119 · cited 1×
“developed a new microfluidic device based on microaspiration that has greatly increased the throughput of the technique ( 1000 cells/h) (67), complementing other microfluidics approaches to measure cell-deformability parameters with a high throughput (68) (Fig.”
BackgroundBoudou, T., Ohayon, J., Arntz, Y., Finet, G., Picart, C., & Tracqui, P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.026 · Cited by 106
Khalilian, M., Navidbakhsh, M., Valojerdi, M. R., Chizari, M., & Eftekhari‐Yazdi, P. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0380 · Cited by 102
Automated Micropipette Aspiration of Single Cells
Shojaei-Baghini, E., Zheng, Y., & Sun, Y. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0791-9 · Cited by 97 · cited 1×
“1 c) are determined microscopically by means of image analysis (39).”
MethodZhao, R., Sider, K. L., & Simmons, C. A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.004 · Cited by 96 · cited 1×
“From the 1970s, microaspiration experiments have remained widely used in the study of cell mechanics, comprising assays of suspended cells—mainly blood cells (1,18–22)— and adherent cells—adhered cells or resuspended cells (5,23–27) —, cell nucleus (28), cell blebs (29), giant unilamellar vesicles (30–33), extracellul…”
BackgroundVigmostad, S. C., Krog, B. L., Nauseef, J. T., Henry, M. D., & Chivukula, V. K. (2015) · Cell Health and Cytoskeleton · doi:10.2147/chc.s71852 · Cited by 96
Critical review: cellular mechanobiology and amoeboid migration
Guck, J. R., Lautenschläger, F., Paschke, S., & Beil, M. (2010) · Integrative Biology · doi:10.1039/c0ib00050g · Cited by 92
Guevorkian, K., & Maître, J. (2016) · Methods in cell biology · doi:10.1016/bs.mcb.2016.11.012 · Cited by 88
Power-law rheology analysis of cells undergoing micropipette aspiration
Zhou, E. H., Quek, S. T., & Lim, C. T. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0197-7 · Cited by 80 · cited 1×
“Regarding the creep function J(t), the standard linear solid model with three parameters and the power-law rheological model with two parameters are customarily used for aspiration experiments (45,46).”
MethodMembrane mechanical properties of synthetic asymmetric phospholipid vesicles
Lu, L., Doak, W. J., Schertzer, J. W., & Chiarot, P. R. (2016) · Soft Matter · doi:10.1039/c6sm01349j · Cited by 76 · cited 1×
“’s model of a hyperelastic sphere (44) (the linearized expression (30) is used, see Eqs.”
MethodRoss, J. L. (2016) · Biophysical Journal · doi:10.1016/j.bpj.2016.07.037 · Cited by 73 · cited 1×
“Indeed, given the large amount of understudied species of molecules (54), biomechanical modeling cannot yet describe in full detail the response of cells and is therefore an active area of research.”
BackgroundSliogeryte, K., Thorpe, S. D., Wang, Z., Thompson, C. L., Gavara, N., & Knight, M. M. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.034 · Cited by 66 · cited 1×
“4 b), which permits inferring mechanosensing activity (49,61).”
BackgroundMicropipette force probe to quantify single-cell force generation: application to T-cell activation
Sawicka, A., Babataheri, A., Dogniaux, S., Barakat, A. I., Gonzalez‐Rodriguez, D., Hivroz, C., & Husson, J. (2017) · Molecular Biology of the Cell · doi:10.1091/mbc.e17-06-0385 · Cited by 66 · cited 2×
“The mechanical behavior of cells is central to the cell state and functions, including growth (1), degree of differentiation (2,3), ability to migrate (4,5), immune cell activation (6), and fate (7).”
BackgroundMethodShao, J., & Xu, J. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1486469 · Cited by 58 · cited 1×
“Micropipette force probe has been used to assess the pushing force by activated T cells (6,63).”
MethodModel for Probing Membrane-Cortex Adhesion by Micropipette Aspiration and Fluctuation Spectroscopy
Alert, R., Casademunt, J., Brugués, J., & Sens, P. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.02.027 · Cited by 56 · cited 1×
“obtained a model that would allow for estimations of the membrane-cortex ligand density and the contractile activity of the cortex (56) in experiments combining micropipette aspiration and interferometric spectroscopy.”
MethodKleinberger, R. M., Burke, N. A. D., Dalnoki‐Veress, K., & Stöver, H. D. H. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.06.033 · Cited by 47
Zhou, E. H., Martínez, F. D., & Fredberg, J. J. (2013) · Nature Materials · doi:10.1038/nmat3574 · Cited by 46 · cited 2×
“In poroelastic (and poroviscoelastic) models, the cell is described as an elastic (or viscoelastic) porous structure dispersed in a viscous fluid (48,55).”
BackgroundLee, L. M., Lee, J. W., Chase, D. L., Gebrezgiabhier, D., & Liu, A. P. (2016) · Biomicrofluidics · doi:10.1063/1.4962968 · Cited by 42 · cited 1×
“developed a new microfluidic device based on microaspiration that has greatly increased the throughput of the technique ( 1000 cells/h) (67), complementing other microfluidics approaches to measure cell-deformability parameters with a high throughput (68) (Fig.”
BackgroundProbing eukaryotic cell mechanics via mesoscopic simulations
Lykov, K., Nematbakhsh, Y., Shang, M., Lim, C. T., & Pivkin, I. V. (2017) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1005726 · Cited by 40 · cited 1×
“developed a discrete particle-based model of a spherical cell, describing the cell membrane, nucleus, and cytoskeleton during the aspiration process (57).”
Gigaseal Mechanics: Creep of the Gigaseal under the Action of Pressure, Adhesion, and Voltage
Slavchov, R. I., Nomura, T., Martinac, B., Sokabe, M., & Sachs, F. (2014) · The Journal of Physical Chemistry B · doi:10.1021/jp506965v · Cited by 34 · cited 1×
“To prevent adhesion of the membrane to the glass in micropipette-aspiration experiments (41), which could lead to overestimates of the cell mechanical properties, different experimental protocols have been reported in the literature (28,42).”
Low-Intensity Pulsed Ultrasound Improves the Functional Properties of Cardiac Mesoangioblasts
Bernal, A., Pérez, L. M., de Lucas, B., Martín, N. S., Kadow‐Romacker, A., Plaza, G. R., Raum, K., & Gálvez, B. G. (2015) · Stem Cell Reviews and Reports · doi:10.1007/s12015-015-9608-6 · Cited by 31
Self-citationShen, Y., Cheng, Y., Uyeda, T. Q. P., & Plaza, G. R. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1884-7 · Cited by 18
Self-citationMechanical phenotyping of stem cells
Keefer, C. L., & Desai, J. P. (2011) · Theriogenology · doi:10.1016/j.theriogenology.2010.11.032 · Cited by 16 · cited 2×
“588 Biophysical Journal 116, 587–594, February 19, 2019 DP E 1⁄4 2p 3fp Lp Rp ; (2)”
BackgroundSpagnol, S. T., Lin, W.-C., Booth, E. A., Ladoux, B., Lazarus, H. M., & Dahl, K. N. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1508-z · Cited by 12 · cited 1×
“The mechanical behavior of cells is central to the cell state and functions, including growth (1), degree of differentiation (2,3), ability to migrate (4,5), immune cell activation (6), and fate (7).”
BackgroundProbing the effect of tip pressure on fungal growth: Application toAspergillus nidulans
González‐Bermúdez, B., Li, Q., Guinea, G. V., Peñalva, M. A., & Plaza, G. R. (2017) · Physical review. E · doi:10.1103/physreve.96.022402 · Cited by 11 · cited 1×
“We developed a procedure to study the influence of the differential pressure applied at the tip, DP, on the growth rate dLp/dt (59), predicting and measuring a DP value that arrests the cell growth.”
MethodSelf-citationSignatures of Mechanosensitive Gating
Morris, R. G. (2017) · Biophysical Journal · doi:10.1016/j.bpj.2016.12.009 · Cited by 6 · cited 1×
“For instance, micropipette aspiration combined with single-particle tracking has been employed in mechanosensitive studies of membrane-embedded ion channels and proteins (62).”
Background
Cited by
Mechanical Adaptability of Tumor Cells in Metastasis
Gensbittel, V., Kräter, M., Harlepp, S., Busnelli, I., Guck, J., & Goetz, J. G. (2021) · Developmental Cell · doi:10.1016/j.devcel.2020.10.011 · Cited by 234
Mittelheisser, V., Gensbittel, V., Bonati, L., Li, W., Tang, L., & Goetz, J. G. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01535-8 · Cited by 109
“A plethora of in vitro techniques, such as micropipette aspiration, atomic force microscopy (AFM) and biomembrane force probe, have been available for measuring the mechanical properties of single cells, tissues and interaction forces between cells 7,211 .”
Lei, M., & Chen, G. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.05.011 · Cited by 12
Metadata
- Authors
- González-Bermúdez, B., Guinea, G. V., & Plaza, G. R.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 116
- Issue
- 4
- Pages
- 587-594
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2909930030
- Cited by
- 175
- References
- 51
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.