The DOI matches its Crossref record; 120 of the 120 references it cites were found in a registry or an index.
Electric field depth–focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designs
Open accessAbstract
Background Various transcranial magnetic stimulation (TMS) coil designs are available or have been proposed. However, key coil characteristics such as electric field focality and attenuation in depth have not been adequately compared. Knowledge of the coil focality and depth characteristics can help TMS researchers and clinicians with coil selection and interpretation of TMS studies. Objective To quantify the electric field focality and depth of penetration of various TMS coils. Methods The electric field distributions induced by 50 TMS coils were simulated in a spherical human head model using the finite element method. For each coil design, we quantified the electric field penetration by the half-value depth, d1/2, and focality by the tangential spread, S1/2, defined as the half-value volume (V1/2) divided by the half-value depth, S1/2 = V1/2/d1/2. Results The 50 TMS coils exhibit a wide range of electric field focality and depth, but all followed a depth–focality tradeoff: coils with larger half-value depth cannot be as focal as more superficial coils. The ranges of achievable d1/2 are similar between coils producing circular and figure-8 electric field patterns, ranging 1.0–3.5 cm and 0.9–3.4 cm, respectively. However, figure-8 field coils are more focal, having S1/2 as low as 5 cm2 compared to 34 cm2 for circular field coils. Conclusions For any coil design, the ability to directly stimulate deeper brain structures is obtained at the expense of inducing wider electrical field spread. Novel coil designs should be benchmarked against comparison coils with consistent metrics such as d1/2 and S1/2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
NON-INVASIVE MAGNETIC STIMULATION OF HUMAN MOTOR CORTEX
Barker, A. T., Jalinous, R., & Freeston, I. L. (1985) · The Lancet · doi:10.1016/s0140-6736(85)92413-4 · Cited by 4,460
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
O’Reardon, J. P., Solvason, H. B., Janicak, P. G., Sampson, S., Isenberg, K. E., Nahas, Z., McDonald, W. M., Avery, D., Fitzgerald, P. B., Loo, C., et al. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2007.01.018 · Cited by 1,910
A comprehensive review of the effects of rTMS on motor cortical excitability and inhibition
Fitzgerald, P. B., Fountain, S., & Daskalakis, Z. J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.06.712 · Cited by 1,024
Electromagnetic fields and energy
Haus, H. A., & Melcher, J. R. (1989) · BiblioBoard Library Catalog (Open Research Library) · Cited by 782
Targeted electrode-based modulation of neural circuits for depression.
Mayberg, H. S. (2009) · Journal of Clinical Investigation · doi:10.1172/jci38454 · Cited by 542
Transcranial magnetic stimulation of deep brain regions: evidence for efficacy of the H-Coil
Zangen, A., Roth, Y., Voller, B., & Hallett, M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.11.008 · Cited by 473
Ueno, S., Tashiro, T., & Harada, K. (1988) · Journal of Applied Physics · doi:10.1063/1.342181 · Cited by 442
Impact of the gyral geometry on the electric field induced by transcranial magnetic stimulation
Thielscher, A., Opitz, A., & Windhoff, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.061 · Cited by 439
Peterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Self-citationKammer, T., Beck, S., Thielscher, A., Laubis-Herrmann, U., & Topka, H. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00513-7 · Cited by 423
Gradient coil design: A review of methods
Turner, R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90209-v · Cited by 418
Effects of coil design on delivery of focal magnetic stimulation. Technical considerations
Cohen, L. G., Roth, B. J., Nilsson, J., Dang, N., Panizza, M., Bandinelli, S., Friauf, W., & Hallett, M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90113-x · Cited by 409
Roth, Y., Amir, A., Levkovitz, Y., & Zangen, A. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31802fa393 · Cited by 389
How the brain tissue shapes the electric field induced by transcranial magnetic stimulation
Opitz, A., Windhoff, M., Heidemann, R. M., Turner, R., & Thielscher, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.069 · Cited by 360
Three-Dimensional Head Model Simulation of Transcranial Magnetic Stimulation
Wagner, T. A., Zahn, M., Grodzinsky, A. J., & Pascual-Leone, A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827925 · Cited by 348
A Coil Design for Transcranial Magnetic Stimulation of Deep Brain Regions
Roth, Y., Zangen, A., & Hallett, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200208000-00008 · Cited by 326
An Introduction to the Basic Principles of Magnetic Nerve Stimulation
Barker, A. T. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00005 · Cited by 324
Handbook of transcranial magnetic stimulation
Pascual‐Leone, Á. (2002) · Cited by 323
Maccabee, P. J., Amassian, V. E., Eberle, L. P., & Cracco, R. Q. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019467 · Cited by 321
Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
A theoretical calculation of the electric field induced in the cortex during magnetic stimulation
Roth, B. J., Saypol, J. M., Hallett, M., & Cohen, L. G. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90103-5 · Cited by 307
Handbook of Transcranial Magnetic Stimulation
Nahas, Z. (2003) · Journal of Psychiatry and Neuroscience · doi:10.1139/jpn.0345 · Cited by 295
Thielscher, A., & Kammer, T. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.019 · Cited by 294
Comparison of the magnetoencephalogram and electroencephalogram
Neil Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 274
Lazzaro, V. D., Oliviero, A., Saturno, E., Pilato, F., Insola, A., Mazzone, P., Profice, P., Tonali, P., & Rothwell, J. (2001) · Experimental Brain Research · doi:10.1007/s002210100722 · Cited by 265
Localizing the site of magnetic brain stimulation in humans
Epstein, C. M., Schwartzberg, D. G., Davey, K. R., & Sudderth, M. (1990) · Neurology · doi:10.1212/wnl.40.4.666 · Cited by 232
(2006) · Bone Marrow Diagnosis · doi:10.1002/9780470987544.ch29 · Cited by 222
Magnetic Seizure Therapy of Major Depression
Lisanby, S. H., Schlaepfer, T. E., Fisch, H.-U., & Sackeim, H. A. (2001) · Archives of General Psychiatry · doi:10.1001/archpsyc.58.3.303 · Cited by 221
Self-citationLevkovitz, Y., Harel, E. V., Roth, Y., Braw, Y., Most, D., Katz, L. N., Sheer, A., Gersner, R., & Zangen, A. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.08.002 · Cited by 217
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Self-citationThielscher, A., & Kammer, T. (2002) · NeuroImage · doi:10.1006/nimg.2002.1282 · Cited by 206
Technical and Practical Aspects of Magnetic Nerve Stimulation
Jalinous, R. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00004 · Cited by 203
Brain stimulation using electromagnetic sources: theoretical aspects
Heller, L., & van Hulsteyn, D. B. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81587-4 · Cited by 178
Deep brain stimulation for treatment-resistant depression
Holtzheimer, P. E., & Hamani, C. (2014) · Deep Brain Stimulation: Technology and Applications (Volume 2) · doi:10.2217/ebo.13.577 · Cited by 171
Lazzaro, V., Oliviero, A., Mazzone, P., Insola, A., Pilato, F., Saturno, E., Accurso, A., Tonali, P., & Rothwell, J. (2001) · Experimental Brain Research · doi:10.1007/s002210100863 · Cited by 169
Developing a More Focal Magnetic Stimulator. Part I: Some Basic Principles
Cohen, D., & Cuffin, B. N. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00013 · Cited by 159
The distribution of induced currents in magnetic stimulation of the nervous system
Tofts, P. S. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/8/008 · Cited by 159
A randomized controlled feasibility and safety study of deep transcranial magnetic stimulation
Levkovitz, Y., Roth, Y., Harel, E. V., Braw, Y., Sheer, A., & Zangen, A. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.061 · Cited by 142
Magnetic brain stimulation and brain size: relevance to animal studies
Weissman, J. D., Epstein, C. M., & DAVEY, K. R. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90135-x · Cited by 138
Computation of electric and magnetic stimulation in human head using the 3-D impedance method
Nadeem, M., Thorlin, T., Gandhi, O. P., & Persson, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813548 · Cited by 138
Krings, T., Buchbinder, B. R., Butler, W. E., Chiappa, K. H., Jiang, H., Rosen, B. R., & Cosgrove, G. R. (1997) · Neurosurgery · doi:10.1097/00006123-199712000-00016 · Cited by 133
Eaton, H. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446182 · Cited by 130
Iron-Core Coils for Transcranial Magnetic Stimulation
Epstein, C. M., & DAVEY, K. R. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200208000-00010 · Cited by 128
Roth, B. J., Cohen, L. G., Hallett, M., Friauf, W. S., & Basser, P. J. (1990) · Muscle & Nerve · doi:10.1002/mus.880130812 · Cited by 126
Detailed 3D models of the induced electric field of transcranial magnetic stimulation coils
Salinas, F. S., Lancaster, J. L., & Fox, P. T. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/016 · Cited by 126
Low-Field Magnetic Stimulation in Bipolar Depression Using an MRI-Based Stimulator
Rohan, M., Parow, A., Stoll, A. L., Demopulos, C., Friedman, S., Dager, S., Hennen, J., Cohen, B. M., & Renshaw, P. F. (2004) · American Journal of Psychiatry · doi:10.1176/appi.ajp.161.1.93 · Cited by 125
Harel, E. V., Zangen, A., Roth, Y., Reti, I. M., Braw, Y., & Levkovitz, Y. (2010) · The World Journal of Biological Psychiatry · doi:10.3109/15622975.2010.510893 · Cited by 125
Balslev, D., Braet, W., McAllister, C. J., & Miall, R. C. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.01.021 · Cited by 120
Consensus: New methodologies for brain stimulation
Huang, Y., Sommer, M., Thickbroom, G. W., Hamada, M., Pascual-Leonne, A., Paulus, W., Claßen, J., Peterchev, A. V., Zangen, A., & Ugawa, Y. (2008) · Brain stimulation · doi:10.1016/j.brs.2008.09.007 · Cited by 112
Self-citationIsserles, M., Rosenberg, O., Dannon, P., Levkovitz, Y., Kotler, M., Deutsch, F., Lerer, B., & Zangen, A. (2010) · Journal of Affective Disorders · doi:10.1016/j.jad.2010.06.038 · Cited by 112
Hayward, G., Mehta, M. A., Harmer, C. J., Spinks, T. J., Grasby, P. M., & Goodwin, G. M. (2007) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2007.05430.x · Cited by 108
Focusing and targeting of magnetic brain stimulation using multiple coils
Ruohonen, J., & Ilmoniemi, R. J. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522474 · Cited by 107
Ravazzani, P., Ruohonen, J., Grandori, F., & Tognola, G. (1996) · Annals of Biomedical Engineering · doi:10.1007/bf02684229 · Cited by 102
The effects of repetitive transcranial magnetic stimulation in the treatment of depression
Fitzgerald, P. B., & Daskalakis, Z. J. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.57 · Cited by 94
Levkovitz, Y., Rabany, L., Harel, E. V., & Zangen, A. (2011) · International Journal of Neuropsychopharmacology · doi:10.1017/s1461145711000642 · Cited by 87
The role of medial prefrontal cortex in theory of mind: A deep rTMS study
Krause, L., Enticott, P. G., Zangen, A., & Fitzgerald, P. B. (2011) · Behavioural Brain Research · doi:10.1016/j.bbr.2011.11.037 · Cited by 85
Transcranial magnetic brain stimulation modulates blepharospasm
Kranz, G., Shamim, E. A., Lin, P. T., Kranz, G. S., & Hallett, M. (2010) · Neurology · doi:10.1212/wnl.0b013e3181f8814d · Cited by 84
Transcranial stimulation of the leg area of the motor cortex in humans
Terao, Y., Ugawa, Y., Sakai, K. L., et al. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1994.tb02650.x · Cited by 82
Focality Assessment in Transcranial Magnetic Stimulation With Double and Cone Coils
Lontis, R., Voigt, M., & Struijk, J. J. (2006) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000229944.63011.a1 · Cited by 79
Wagner, T., Gangitano, M., Romero, J. R., Théoret, H., Kobayashi, M., Anschel, D. J., Ives, J. R., Cuffin, N., Schomer, D. L., & Pascual‐Leone, Á. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00861-9 · Cited by 77
Rösler, K. M., Hess, C. W., Heckmann, R., et al. (1989) · Neuroscience Letters · doi:10.1016/0304-3940(89)90711-8 · Cited by 76
A theoretical comparison of electric and magnetic stimulation of the brain
Saypol, J. M., Roth, B. J., Cohen, L. G., & Hallett, M. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02584306 · Cited by 76
Transcranial magnetic stimulation: Improved coil design for deep brain investigation
Crowther, L. J., Marketos, P., Williams, P., et al. (2011) · Journal of Applied Physics · doi:10.1063/1.3563076 · Cited by 71
Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS)
Deng, Z., Peterchev, A. V., & Lisanby, S. H. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650502 · Cited by 70
Self-citationTranscranial Magnetic Stimulation of Deep Brain Regions: Principles and Methods
Roth, Y., Padberg, F., & Zangen, A. (2007) · KARGER eBooks · doi:10.1159/000101039 · Cited by 69
A novel electric design for electromagnetic stimulation-the Slinky coil
Ren, C., TARJAN, P. P., & Popović, D. B. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.412658 · Cited by 68
Kim, D.-H., Georghiou, G. E., & Won, C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870244 · Cited by 67
T- Omega method using hierarchal edge elements
Webb, J. P., & Forghani, B. (1995) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:19951439 · Cited by 66
Sekino, M., & Ueno, S. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.828982 · Cited by 63
Effects of low-field magnetic stimulation on brain glucose metabolism
Volkow, N. D., Tomasi, D., Wang, G., Fowler, J. S., Telang, F., Wang, R., Alexoff, D., Logan, J., Wong, C., Pradhan, K., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.015 · Cited by 61
Coil design for real and sham transcranial magnetic stimulation
Ruohonen, J., Ollikainen, M., Nikouline, V., Virtanen, J., & Ilmoniemi, R. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821731 · Cited by 60
Suppressing the Surface Field During Transcranial Magnetic Stimulation
DAVEY, K. R., & Riehl, M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862545 · Cited by 59
Current density threshold for the stimulation of neurons in the motor cortex area
Kowalski, T. J., Silny, J., & Büchner, H. (2002) · Bioelectromagnetics · doi:10.1002/bem.10036 · Cited by 59
Enticott, P. G., Kennedy, H. A., Zangen, A., & Fitzgerald, P. B. (2010) · Journal of Ect · doi:10.1097/yct.0b013e3181f07948 · Cited by 58
Magnetic stimulation of the motor cortex-theoretical considerations
Grandori, F., & Ravazzani, P. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76385 · Cited by 58
Antidepressant-like effects of cranial stimulation within a low-energy magnetic field in rats
Carlezon, W. A., Rohan, M. L., Mague, S. D., Meloni, E. G., Parsegian, A., Cayetano, K. R., Tomasiewicz, H. C., Rouse, E. D., Cohen, B. M., & Renshaw, P. F. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2004.12.011 · Cited by 57
Toschi, N., Welt, T., Guerrisi, M., & Keck, M. (2008) · Physica medica (Testo stampato) · doi:10.1016/j.ejmp.2008.01.005 · Cited by 56
A 3-D differential coil design for localized magnetic stimulation
Hsu, K.-H., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.951519 · Cited by 55
Developing a More Focal Magnetic Stimulator. Part II
Yunokuchi, K., & Cohen, D. I. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00014 · Cited by 54
Chen, M., & Mogul, D. J. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.01.010 · Cited by 53
Sekino, M., & Ueno, S. (2002) · Journal of Applied Physics · doi:10.1063/1.1454987 · Cited by 52
Han, B. H., Chun, I. K., Lee, S. C., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824123 · Cited by 51
Analysis of efficiency of magnetic stimulation
Hsu, K.-H., Nagarajan, S. S., & Durand, D. M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.818473 · Cited by 50
Deep TMS in a resistant major depressive disorder: a brief report
Rosenberg, O., Shoenfeld, N., Zangen, A., Kotler, M., & Dannon, P. N. (2010) · Depression and Anxiety · doi:10.1002/da.20689 · Cited by 48
Differential effects of deep TMS of the prefrontal cortex on apathy and depression
Levkovitz, Y., Sheer, A., Harel, E. V., Katz, L. N., Most, D., Zangen, A., & Isserles, M. (2011) · Brain stimulation · doi:10.1016/j.brs.2010.12.004 · Cited by 48
Deng, Z., Lisanby, S. H., & Peterchev, A. V. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334091 · Cited by 46
Self-citationToschi, N., Welt, T., Guerrisi, M., & Keck, M. (2009) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2008.04.008 · Cited by 45
Rosenberg, O., Roth, Y., Kotler, M., Zangen, A., & Dannon, P. N. (2011) · Annals of General Psychiatry · doi:10.1186/1744-859x-10-3 · Cited by 44
Fadini, T., Matthäus, L., Rothkegel, H., Sommer, M., Tergau, F., Schweikard, A., Paulus, W., & Nitsche, M. A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.02.176 · Cited by 42
Theory of multichannel magnetic stimulation: toward functional neuromuscular rehabilitation
Ruohonen, J., Ravazzani, P., Grandori, F., et al. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764941 · Cited by 42
Analysis of the distribution of currents induced by a changing magnetic field in a volume conductor
Branston, N. M., & Tofts, P. S. (1991) · Physics in Medicine and Biology · doi:10.1088/0031-9155/36/2/001 · Cited by 41
Mini-coil for magnetic stimulation in the behaving primate
Tischler, H., Wolfus, S., Friedman, A., Perel, E., Pashut, T., Michal Lavidor, B., Korngreen, A., Yeshurun, Y., & Bar‐Gad, I. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.10.015 · Cited by 40
DAVEY, K. R., Epstein, C. M., George, M. S., et al. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00240-2 · Cited by 35
Effectiveness of a second deep TMS in depression: A brief report
Rosenberg, O., Isserles, M., Levkovitz, Y., Kotler, M., Zangen, A., & Dannon, P. N. (2011) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2011.02.015 · Cited by 35
Response to deep TMS in depressive patients with previous electroconvulsive treatment
Rosenberg, O., Zangen, A., Stryjer, R., Kotler, M., & Dannon, P. N. (2009) · Brain stimulation · doi:10.1016/j.brs.2009.12.001 · Cited by 35
Ho, S. L., Xu, G., Fu, W. N., et al. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2025892 · Cited by 33
Computer-Aided Performance Evaluation of a Multichannel Transcranial Magnetic Stimulation System
Im, C., & Lee, C. (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.883913 · Cited by 33
High-Permeability Core Coils for Transcranial Magnetic Stimulation of Deep Brain Regions
Salvador, R., Miranda, P. C., Roth, Y., et al. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353885 · Cited by 32
Determining the cortical target of transcranial magnetic stimulation
Thielscher, A., & Wichmann, F. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.021 · Cited by 31
Salvador, R., Miranda, P. C., Roth, Y., et al. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/10/010 · Cited by 26
Lu, M., & Ueno, S. (2009) · Journal of Applied Physics · doi:10.1063/1.3059614 · Cited by 24
The Optimal Design of Magnetic Coil in Transcranial Magnetic Stimulation
Xu, G., Wang, M., Chen, Y., et al. (2005) · doi:10.1109/iembs.2005.1615917 · Cited by 24
“Slinky” coils for neuromagnetic stimulation
Zimmermann, K. P., & Simpson, R. K. (1996) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/0924-980x(95)00227-c · Cited by 21
Computer modelling of brain cortex excitation by magnetic field pulses
Leo, R. D., Cerri, G., Balducci, D., Moglie, F., Scarpino, O., & Guidi, M. (1992) · Journal of Medical Engineering & Technology · doi:10.3109/03091909209030218 · Cited by 21
Toroidal coil models for transcutaneous magnetic simulation of nerves
Carbunaru, R., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.915709 · Cited by 21
A numerically optimized active shield for improved transcranial magnetic stimulation targeting
Hernández-García, L., Hall, T. L., Gomez, L. J., & Michielssen, E. (2010) · Brain stimulation · doi:10.1016/j.brs.2010.05.001 · Cited by 20
Gasca, F., Richter, L., & Schweikard, A. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626674 · Cited by 15
Valproate-related peripheral oedema: a manageable but probably neglected condition
Lin, S.-T., Chen, C., Yen, C., et al. (2009) · The International Journal of Neuropsychopharmacology · doi:10.1017/s1461145709000509 · Cited by 15
Effects of TMS coil geometry on stimulation specificity
Talebinejad, M., & Musallam, S. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626840 · Cited by 13
Transcranial magnetic stimulation coil with electronically switchable active and sham modes
Deng, Z., & Peterchev, A. V. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090561 · Cited by 13
Self-citationSynthesizing a Field Source for Magnetic Stimulation of Peripheral Nerves
Barba, P. D., Mognaschi, M. E., & Savini, A. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.905289 · Cited by 10
Magnetic Nerve Stimulation: Field Focality and Depth of Penetration
Al-Mutawaly, N., de Bruin, H., & Findlay, R. D. (2001) · doi:10.21236/ada411028 · Cited by 6
P19.12 Pain relief by deep repetitive transcranial magnetic stimulation applied with the H-coil
Tartaglia, G. G., Gabriele, M., Frasca, V., et al. (2011) · Clinical Neurophysiology · doi:10.1016/s1388-2457(11)60513-0 · Cited by 5
Libera, D. D., Colombo, B., Coppi, E., Straffi, L., Chieffo, R., Spagnolo, F., Bianco, M., Ferrari, L. D., Velikova, S., Nuara, A., et al. (2011) · Clinical Neurophysiology · doi:10.1016/s1388-2457(11)60520-8 · Cited by 5
Evoked motor response following deep transcranial magnetic stimulation in a cynomolgus monkey
Ishii, K., Matsuzaka, Y., Izumi, S., et al. (2008) · Brain stimulation · doi:10.1016/j.brs.2008.06.162 · Cited by 5
Magnetic nerve stimulation: field focality and depth of penetration
Al-Mutawaly, N., de Bruin, H., & Findlay, D. (2005) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019082 · Cited by 5
Analysis and Design of Whole-Head Magnetic Brain Stimulators: A Simulation Study
Lee, C., Im, C., & Jung, H. K. (2007) · International Journal of Control Automation and Systems · Cited by 1
Cited by
Lefaucheur, J.-P., Aleman, A., Baeken, C., Benninger, D. H., Brunelin, J., Di Lazzaro, V., Filipović, S. R., Grefkes, C., Hasan, A., Hummel, F. C., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.002 · Cited by 2,382
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
Self-citationStanford Neuromodulation Therapy (SNT): A Double-Blind Randomized Controlled Trial
Cole, E. J., Phillips, A. L., Bentzley, B. S., Stimpson, K. H., Nejad, R., Barmak, F., Veerapal, C., Khan, N., Cherian, K., Felber, E., et al. (2022) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2021.20101429 · Cited by 795
McClintock, S. M., Reti, I. M., Carpenter, L. L., McDonald, W. M., Dubin, M., Taylor, S. F., Cook, I. A., O’Reardon, J., Husain, M. M., Wall, C., et al. (2018) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.16cs10905 · Cited by 693
Self-citationPerera, T., George, M. S., Grammer, G., Janicak, P. G., Pascual-Leone, A., & Wirecki, T. S. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.03.010 · Cited by 674
Metadata
- Authors
- Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 6
- Issue
- 1
- Pages
- 1-13
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2123712730
- Cited by
- 1,073
- References
- 120
- FWCI
- 13.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.