CoChat

Short-Latency Artifacts Associated with Concurrent TMS–EEG

Open access
Rogasch, Nigel C., Thomson, Richard H., Daskalakis, Zafiris J., Fitzgerald, Paul B. · 2013 · Brain Stimulation
Cited by 117

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND Concurrent transcranial magnetic stimulation and electroencephalography (TMS-EEG) is an emerging method for studying cortical network properties. However, various artifacts affect measurement of TMS-evoked cortical potentials (TEPs), especially within 30 ms of stimulation. OBJECTIVE/HYPOTHESIS The aim of this study was to assess the origin and recovery of short-latency TMS-EEG artifacts (<30 ms) using different stimulators and under different experimental conditions. METHODS EEG was recorded during TMS delivered to a phantom head (melon) and 12 healthy volunteers with different TMS machines, at different scalp positions, at different TMS intensities, and following paired-pulse TMS. Recovery from the TMS artifact and other short-latency artifacts were compared between conditions. RESULTS Following phantom stimulation, the artifact resulting from different TMS machines (Magstim 200, Magventure MagPro R30 and X100) and pulse shapes (monophasic and biphasic) resulted in different artifact profiles. After accounting for differences between machines, TMS artifacts recovered within ∼12 ms. This was replicated in human participants, however a large secondary artifact (peaks at 5 and 10 ms) became prominent following stimulation over lateral scalp positions, which only recovered after ∼25-40 ms. Increasing TMS intensity increased secondary artifact amplitude over both motor and prefrontal cortex. There was no consistent modulation of the secondary artifact following inhibitory paired-pulse TMS (interstimulus interval = 100 ms) over motor cortex. CONCLUSIONS The secondary artifact observed in humans is consistent with activation of scalp muscles following TMS. TEPs can be recorded within a short period of time (10-12 ms) following TMS, however measures must be taken to avoid muscle stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2013.04.004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • The role of the coil click in TMS assessed with simultaneous EEG

    Nikouline, V., Ruohonen, J., & Ilmoniemi, R. J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00070-x · Cited by 269 · cited 1×

    “These include auditoryevoked potentials resulting from the coil click [4,5], involuntary blinking [6] and somatosensory-evoked potentials resulting from small coil vibrations, trigeminal nerve stimulation or joint movement following evoked muscle responses (i.”
    Background

Show all 1 references

Cited by

Metadata

Authors
Rogasch, N. C., Thomson, R. H., Daskalakis, Z. J., & Fitzgerald, P. B.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2013-11
Volume
6
Issue
6
Pages
868-876
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2030279250
Cited by
117
References
1
FWCI
2.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.