CoChat

Dose-controlled tDCS reduces electric field intensity variability at a cortical target site

Open access
Evans, Carys, Bachmann, Clarissa, Lee, Jenny S.A., Gregoriou, Evridiki, Ward, Nick, Bestmann, Sven · 2020 · Brain Stimulation
Cited by 164

The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Variable effects limit the efficacy of transcranial direct current stimulation (tDCS) as a research and therapeutic tool. Conventional application of a fixed-dose of tDCS does not account for inter-individual differences in anatomy (e.g. skull thickness), which varies the amount of current reaching the brain. Individualised dose-control may reduce the variable effects of tDCS by reducing variability in electric field (E-field) intensities at a cortical target site. OBJECTIVE: To characterise the variability in E-field intensity at a cortical site (left primary motor cortex; M1) and throughout the brain for conventional fixed-dose tDCS, and individualised dose-controlled tDCS. METHODS: The intensity and distribution of the E-field during tDCS was estimated using Realistic Volumetric Approach to Simulate Transcranial Electric Stimulation (ROAST) in 50 individual brain scans taken from the Human Connectome Project, for fixed-dose tDCS (1 mA & 2 mA) and individualised dose-controlled tDCS targeting left M1. RESULTS: With a fixed-dose (1 mA & 2 mA), E-field intensity in left M1 varied by more than 100% across individuals, with substantial variation observed throughout the brain as well. Individualised dose-control ensured the same E-field intensity was delivered to left M1 in all individuals. Its variance in other regions of interest (right M1 and area underneath the electrodes) was comparable with fixed- and individualised-dose. CONCLUSIONS: Individualised dose-control can eliminate the variance in E-field intensities at a cortical target site. Assuming that the current delivered to the brain directly determines its physiological and behavioural consequences, this approach may allow for reducing the known variability of tDCS effects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2019.10.004

Cites

75 of 75 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 75 references

Cited by

Metadata

Authors
Evans, C., Bachmann, C., Lee, J. S. A., Gregoriou, E., Ward, N., & Bestmann, S.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2020-01
Volume
13
Issue
1
Pages
125-136
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2979888413
Cited by
164
References
75
FWCI
7.12
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.