The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Airborne transmission of infectious respiratory diseases in indoor environments has drawn our attention for decades, and this issue is revitalized with the outbreak of severe acute respiratory syndrome (SARS). One of the concerns is that there may be multiple transmission routes across households in high-rise residential buildings, one of which is the natural ventilative airflow through open windows between flats, caused by buoyancy effects. Our early on-site measurement using tracer gases confirmed qualitatively and quantitatively that the re-entry of the exhaust-polluted air from the window of the lower floor into the adjacent upper floor is a fact. This study presents the modeling of this cascade effect using computational fluid dynamics (CFD) technique. It is found that the presence of the pollutants generated in the lower floor is generally lower in the immediate upper floor by two orders of magnitude, but the risk of infection calculated by the Wells–Riley equation is only around one order of magnitude lower. It is found that, with single-side open-window conditions, wind blowing perpendicularly to the building may either reinforce or suppress the upward transport, depending on the wind speed. High-speed winds can restrain the convective transfer of heat and mass between flats, functioning like an air curtain. Despite the complexities of the air flow involved, it is clear that this transmission route should be taken into account in infection control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Heat Transfer and Fluid Flow
Patankar, S. V. (2018) · CRC Press eBooks · doi:10.1201/9781482234213 · Cited by 23,360
Numerical Heat Transfer and Fluid Flow
Hsu, C.-J. (1981) · Nuclear Science and Engineering · doi:10.13182/nse81-a20112 · Cited by 15,125
Renormalization group analysis of turbulence. I. Basic theory
Yakhot, V., & Orszag, S. A. (1986) · Journal of Scientific Computing · doi:10.1007/bf01061452 · Cited by 4,265
Renormalization-Group Analysis of Turbulence
Yakhot, V., & Orszag, S. A. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.1722 · Cited by 1,708 · cited 1×
“The turbulent effect is modeled by the RNG k-e model [9] .”
MethodOn predicting particle-laden turbulent flows
Elghobashi, S. (1994) · Applied Scientific Research · doi:10.1007/bf00936835 · Cited by 1,554 · cited 1×
“Temperature-driven single-sided natural ventilation through large openings has been fully studied in regard to air change rate [7] and the resulting indoor air quality and comfort level [8] by experimental works [9] , theoretical predictions [10] , and computational fluid dynamics (CFD) simulations [11] .”
Background(2005) · PsycEXTRA Dataset · doi:10.1037/e545842006-001 · Cited by 1,274
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055 · cited 1×
“[3] reviewed over 40 studies on the relationship between the transmission of infection and ventilation systems in hospitals, offices, aircraft cabins, etc.”
BackgroundSelf-citationAIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932 · cited 1×
“Based on the knowledge of infection dose (the number of organisms required to cause infection), the risk of airborne infection and ventilation rate per person can be correlated by Wells–Riley equation [31]:”
MethodToward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 2×
“[14] suggested that evaporation from respiratory particles with an initial diameter less than 20 mm be treated as an instantaneous process.”
BackgroundThe size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803 · cited 1×
“Temperature-driven single-sided natural ventilation through large openings has been fully studied in regard to air change rate [7] and the resulting indoor air quality and comfort level [8] by experimental works [9] , theoretical predictions [10] , and computational fluid dynamics (CFD) simulations [11] .”
BackgroundTransmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744 · cited 1×
“On the other hand, recent systematic reviews [6, 7] concluded that person to person respiratory virus transmission could occur in three possible modes: airborne transmission, droplet transmission, and direct contact with secretions (or fomites).”
BackgroundBuilding ventilation: theory and measurement
(1997) · Choice Reviews Online · doi:10.5860/choice.35-2135 · Cited by 734 · cited 1×
“The wind profile in an urban environment is calculated by the following equation [27]:”
MethodMODELING INDOOR PARTICLE DEPOSITION FROM TURBULENT FLOW ONTO SMOOTH SURFACES
K. Lai, A. C., & Nazaroff, W. W. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00536-4 · Cited by 696 · cited 2×
“Although, according to the deposition model by Lai and Nazaroff [25] , high friction velocity in the boundary layer will also increase the deposition velocity, this effect is negligible for particles larger than 2.5 mm because deposition onto the upward facing surfaces caused by gravitational force constitutes most of…”
MethodInfluentialTang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667 · cited 1×
“Airborne transmission is deemed as long-range aerosol transmission, which refers to the situation that agents can be carried long distances (within a room or between rooms, generally greater than 1m) by air flows [2].”
BackgroundDroplet fate in indoor environments, or can we prevent the spread of infection?
Morawska, L. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00432.x · Cited by 635 · cited 3×
“Our previous simulations also exhibited this cascade effect in windless cases [14] .”
BackgroundMethodInfluentialZhang, Z., & Chen, Q. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.01.014 · Cited by 422
Natural Ventilation for the Prevention of Airborne Contagion
Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., et al. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040068 · Cited by 420 · cited 1×
“median ventilation of 28 air changes per hour (ACH), more than double that of mechanically ventilated rooms [5].”
BackgroundRole of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Numerical approaches for motion of dispersed particles, droplets and bubbles
Loth, E. (2000) · Progress in Energy and Combustion Science · doi:10.1016/s0360-1285(99)00013-1 · Cited by 403 · cited 1×
“The computations are carried out by using a commercial program, Fluent [15] .”
MethodParticle deposition in turbulent duct flows—comparisons of different model predictions
Tian, L., & Ahmadi, G. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2006.12.003 · Cited by 399
Sze To, G. N., & Chao, C. Y. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00621.x · Cited by 383
Recent progress in CFD modelling of wind field and pollutant transport in street canyons
LI, X., LIU, C., LEUNG, D., & LAM, K. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.04.055 · Cited by 378 · cited 1×
“Given the low-speed conditions, 8% is acceptable since a general estimation of it in the wind field is 10% [36] .”
BackgroundNatural Ventilation in Buildings, a Design Handbook
Allard, F. (1998) · HAL · Cited by 364
Modeling particle distribution and deposition in indoor environments with a new drift–flux model
Chen, F., Yu, S. C. M., & Lai, A. C. K. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.09.044 · Cited by 347 · cited 1×
“[27] experimentally investigated the concentration distributions of mono-dispersed 10 mm particles with a material density of 1400 kg/m 3 in a simple model room using a phase Doppler anemometry system (Fig.”
MethodImproved numerical simulation of aerosol deposition in an idealized mouth–throat
Matida, E. A., Finlay, W. H., Lange, C. F., & Grgic, B. (2004) · Journal of Aerosol Science · doi:10.1016/s0021-8502(03)00381-1 · Cited by 293 · cited 2×
“This finding is supported by the experiment by Wilson and Kiel [29] .”
BackgroundResultDesign analysis of single-sided natural ventilation
Allocca, C., Chen, Q., & Glicksman, L. R. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00239-6 · Cited by 292 · cited 2×
“[12] , this domain is large enough to obtain the true results.”
BackgroundModeling particle dispersion and deposition in indoor environments
Gao, N. P., & Niu, J. L. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.016 · Cited by 273
Self-citationThe Airborne Transmission of Infection in Hospital Buildings: Fact or Fiction?
Beggs, C. B. (2003) · Indoor and Built Environment · doi:10.1177/1420326x03012001002 · Cited by 220 · cited 1×
“Beggs’s study in hospital buildings concluded that the contribution of airborne micro-organisms to the spread of infection is likely to be underestimated currently although contact-spread is the principal route of transmission for most infections [1].”
BackgroundUijttewaal, W. S. J., & Oliemans, R. V. A. (1996) · Physics of Fluids · doi:10.1063/1.869046 · Cited by 214
Characteristics of airflow from open windows
Heiselberg, P., Svidt, K., & Nielsen, P. V. (2001) · Building and Environment · doi:10.1016/s0360-1323(01)00012-9 · Cited by 209 · cited 1×
“The turbulent effect is modeled by the RNG k-e model [9] .”
MethodSelf-citation04/00989 Design analysis of single-sided natural ventilation
(2004) · Fuel and Energy Abstracts · doi:10.1016/s0140-6701(04)93371-1 · Cited by 199
Li, Y., Duan, S., Yu, I. T. S., & Wong, T. W. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00318.x · Cited by 194
Large eddy simulation of particle deposition in a vertical turbulent channel flow
Wang, Q., & Squires, K. D. (1996) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(96)00007-9 · Cited by 192 · cited 1×
“[22] using low-Reynoldsnumber k-e models (3.8 W/m 2 K).”
InfluentialStudy of natural ventilation in buildings with LES
Jiang, Y. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 179
Chao, C. Y. H., & Wan, M. P. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00426.x · Cited by 139 · cited 2×
“Heat loss due to imperfect insulation at the top and bottom walls in the experiment reduces the core temperature at any level [18] .”
BackgroundPrediction of room air motion by Reynolds-stress models
Chen, Q. (1996) · Building and Environment · doi:10.1016/0360-1323(95)00049-6 · Cited by 139 · cited 1×
“The DRW model assumes turbulence is isotropic and the random velocity fluctuations follow a Gaussian probability distribution:”
BackgroundLarge eddy simulation of indoor airflow with a filtered dynamic subgrid scale model
Zhang, W., & Chen, Q. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00348-8 · Cited by 128 · cited 1×
“Thus, isotropic decomposition of kinetic energy over-predicts the deposition rate of small particles [20, 21] .”
BackgroundEffective depth of fresh air distribution in rooms with single-sided natural ventilation
Gan, G. (2000) · Energy and Buildings · doi:10.1016/s0378-7788(99)00006-7 · Cited by 125
Numerical simulation of aerosol deposition in a 3-D human nasal cavity using RANS, RANS/EIM, and LES
Liu, Y., Matida, E. A., Gu, J., & Johnson, M. R. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.003 · Cited by 122 · cited 1×
“[28] and Allocca et al.”
On the effect of anisotropy on the turbulent dispersion and deposition of small particles
Wang, Y., & James, P. W. (1999) · International Journal of Multiphase Flow · doi:10.1016/s0301-9322(98)00053-6 · Cited by 108 · cited 1×
“[23] carried out wind tunnel tests to investigate the airflow around a building-like model, whose dimensions are 250 mm (H) Â 250 mm (L) Â 250 mm (W) with a wall thickness of 6 mm (Fig.”
Lai, A. C. K., & Chen, F. (2006) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2006.06.008 · Cited by 105
Niu, J., & Tung, T.-H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00500.x · Cited by 102 · cited 3×
“On-site measurements were carried out at Wing Shui House in the spring from January to February of 2005 [13].”
BackgroundMethodResultInfluentialSelf-citationTemperature-driven single-sided ventilation through a large rectangular opening
Favarolo, P. A., & Manz, H. (2004) · Building and Environment · doi:10.1016/j.buildenv.2004.08.003 · Cited by 85 · cited 1×
“Temperature-driven single-sided natural ventilation through large openings has been fully studied in regard to air change rate [7] and the resulting indoor air quality and comfort level [8] by experimental works [9] , theoretical predictions [10] , and computational fluid dynamics (CFD) simulations [11] .”
BackgroundUsing large eddy simulation to study particle motions in a room
Béghein, C., Jiang, Y., & Chen, Q. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00373.x · Cited by 84
Cited by
Sze To, G. N., & Chao, C. Y. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00621.x · Cited by 383
Metadata
- Authors
- Gao, N. P., Niu, J. L., Perino, M., & Heiselberg, P.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2008-11
- Volume
- 43
- Issue
- 11
- Pages
- 1805-1817
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2019982837
- Cited by
- 188
- References
- 46
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.