The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Ventilation rates in schools and pupils’ performance
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Wargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390951 · Cited by 364
Mechanisms underlying Children's susceptibility to environmental toxicants.
Faustman, E. M., Silbernagel, S. M., Fenske, R. A., Burbacher, T. M., & Ponce, R. A. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108s113 · Cited by 344
Association between substandard classroom ventilation rates and students’ academic achievement
Haverinen-Shaughnessy, U., Moschandreas, D. J., & Shaughnessy, R. J. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00686.x · Cited by 311
Mi, Y.-H., Norbäck, D., Tao, J., Mi, Y.-L., & Ferm, M. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00439.x · Cited by 212
Clements-Croome, D. J., Awbi, H. B., Bakó-Biró, Z., Kochhar, N., & Williams, M. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.018 · Cited by 203
Self-citationWargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390950 · Cited by 194
SPES: A psychological test system to diagnose environmental hazards
Iregren, A., Gamberale, F., & Kjellberg, A. (1996) · Neurotoxicology and Teratology · doi:10.1016/0892-0362(96)00033-5 · Cited by 79
Zhao, Z., Elfman, L., Wang, Z. H., Zhang, Z., & Norbäck, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00433.x · Cited by 57
Kildesø, J., Wyon, D., Skov, T., & Schneider, T. (1999) · Scandinavian Journal of Work, Environment and Health · doi:10.5271/sjweh.446 · Cited by 51
Ventilation Rates in Schools and Learning Performance
Kochhar, N., & Williams, M. (2007) · Cited by 47
Self-citationMental performance by secondary school pupils in relation to the quality of indoor air
Smedje, G., Norbäck, D., & Edling, C. (1996) · Cited by 22
Cited by
Barrett, P., Davies, F., Zhang, Y., & Barrett, L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.013 · Cited by 706
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Self-citationThe ventilation problem in schools: literature review
Fisk, W. J. (2017) · Indoor Air · doi:10.1111/ina.12403 · Cited by 333
Providing better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Carbon dioxide capture with zeotype materials
Fu, D., & Davis, M. E. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00508e · Cited by 284
Metadata
- Authors
- Bakó-Biró, Z., Clements-Croome, D. J., Kochhar, N., Awbi, H. B., & Williams, M. J.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2012-02
- Volume
- 48
- Pages
- 215-223
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W1970946684
- Cited by
- 580
- References
- 17
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.