Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This study employed a multi-component Eulerian-Lagrangian approach to model the evaporation and dispersion of cough droplets in quiescent air. The approach is featured with a continuity equation being explicitly solved for water vapor, which allows comprehensively considering the effects of inhomogeneous humidity field on droplets evaporation and movement. The computational fluid dynamics (CFD) computations based on the approach achieved a satisfactory agreement with the theoretical models reported in the literature. The results demonstrated that the evaporation-generated vapor and super-saturated wet air exhaled from the respiratory tracks forms a “vapor plume” in front of the respiratory track opening, which, despite the short life time, significantly impedes the evaporation of the droplets captured in it. The study also revealed that due to the droplet size reduction induced by evaporation, both the number density of airborne droplets and mass concentration of inhalable pathogens remarkably increased, which can result in a higher risk of infection. Parametric studies were finally conducted to evaluate the factors affecting droplet evaporation. Summary The study demonstrated the importance of considering inhomogeneous humidity field when modelling the evaporation and dispersion of cough droplets. The multi-component Eulerian-Lagrangian model presented in this study provides a comprehensive approach to address different influential factors in a wide parametric range, which will enhance the assessment of the health risks associated with droplet exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particulate air pollution as a predictor of mortality in a prospective study of U.S. adults.
Pope, C. A., Thun, M. J., Namboodiri, M. M., Dockery, D. W., Evans, J. S., Speizer, F. E., & Heath, C. W. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.3.7881654 · Cited by 2,911
(2006) · A-to-Z Guide to Thermodynamics, Heat and Mass Transfer, and Fluids Engineering · doi:10.1615/atoz.e.evaofdrop · Cited by 2,132
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087 · cited 1×
“[24] , were employed to specify the droplet injection conditions.”
MethodHow far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966 · cited 2×
“In recent years, a couple of mathematic models [7,9,13,16] were developed in which the effects of respiratory jets, air turbulence, droplet salinity and ambient humidity were partially considered.”
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 2×
“Respiratory droplets are composed of water and a small amount of non-volatile compounds including sodium chloride, carbohydrate, lipids, protein and microorganisms [7,8].”
Violent expiratory events: on coughing and sneezing
Bourouiba, L., Dehandschoewercker, E., & Bush, J. W. M. (2014) · Journal of Fluid Mechanics · doi:10.1017/jfm.2014.88 · Cited by 828 · cited 1×
“Droplets expulsion by a human cough [26].”
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803 · cited 1×
“This means that as water evaporates, some free-falling large droplets could become airborne [10], leading to an elevated number density of inhalable droplets in the breathing zone and an increased probability of infection [11,12].”
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665 · cited 2×
“[2], the droplets generated from human coughing, sneezing and talking are mostly between 1 nm and 500 μm.”
Flow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605 · cited 2×
“(a) Air flow rate of a single cough [19].”
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“The classic Wells evaporation-falling curve (1934) [15] was widely used to estimate the droplet size as a function of time.”
Cited by
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
Feng, Y., Marchal, T., Sperry, T., & Yi, H. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105585 · Cited by 406
Sneezing and asymptomatic virus transmission
Busco, G., Yang, S. R., Seo, J., & Hassan, Y. A. (2020) · Physics of Fluids · doi:10.1063/5.0019090 · Cited by 188
Metadata
- Authors
- Li, X., Shang, Y., Yan, Y., Yang, L., & Tu, J.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 128
- Pages
- 68-76
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2769844196
- Cited by
- 182
- References
- 24
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.