CoChat

Remote Monitoring of Patients With Heart Failure: A White Paper From the Heart Failure Society of America Scientific Statements Committee

Dickinson, Michael G., Allen, Larry A., Albert, Nancy A., DiSalvo, Thomas, Ewald, Gregory A., Vest, Amanda R., Whellan, David J., Zile, Michael R., Givertz, Michael M. · 2018 · Journal of Cardiac Failure
Cited by 86

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

BACKGROUND After several neutral telehealth trials, the positive findings and subsequent Food and Drug Administration approval of an implantable pulmonary arterial pressure monitor (PAPM) led to renewed interest in remote patient monitoring (RPM). Here we seek to provide contemporary guidance on the appropriate use of RPM technology. RESULTS Although early trials of external RPM devices suggested benefit, subsequent multicenter trials failed to demonstrate improved outcomes. Monitoring features of cardiac implantable electronic devices (CIEDs) also did not deliver improved HF outcomes, newer, multisensor algorithms may be better. Earlier technologies using direct pressure measurement via implanted devices failed to show benefit owing to complications or failure. Recently, 1 PAPM showed benefit in a randomized controlled trial. Although not showing cost reduction, cost-benefit analysis of that device suggests that it may meet acceptable standards. Additional research is warranted and is in progress. Consumer-owned electronic devices are becoming more pervasive and hold hope for future benefit in HF management. Practical aspects around RPM technology include targeting of risk populations, having mechanisms to ensure patient adherence to monitoring, and health care team structures that act on the data. CONCLUSIONS Based on available evidence, routine use of external RPM devices is not recommended. Implanted devices that monitor pulmonary arterial pressure and/or other parameters may be beneficial in selected patients or when used in structured programs, but the value of these devices in routine care requires further study. Future research is also warranted to better understand the cost-effectiveness of these devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cardfail.2018.08.011

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 86

Metadata

Authors
Dickinson, M. G., Allen, L. A., Albert, N. A., DiSalvo, T., Ewald, G. A., Vest, A. R., Whellan, D. J., Zile, M. R., & Givertz, M. M.
Venue
Journal of Cardiac Failure
Publisher
Elsevier BV
Published
2018-10
Volume
24
Issue
10
Pages
682-694
ISSN
1071-9164 (ISSN-L)
OpenAlex
W2896612302
Cited by
86
References
18
FWCI
9.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Remote Monitoring of Patients With Heart Failure: A White Paper From the Heart Failure Society of America Scientific Statements Committee. https://app.cochat.ai/papers/10.1016/j.cardfail.2018.08.011
The paper
Dickinson, M. G., Allen, L. A., Albert, N. A., DiSalvo, T., Ewald, G. A., Vest, A. R., Whellan, D. J., Zile, M. R., & Givertz, M. M. (2018). Remote Monitoring of Patients With Heart Failure: A White Paper From the Heart Failure Society of America Scientific Statements Committee. Journal of Cardiac Failure. https://doi.org/10.1016/j.cardfail.2018.08.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.