The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Degradation of tetracycline by peroxymonosulfate activated with zero-valent iron: Performance, intermediates, toxicity and mechanism
Abstract
In this paper, the degradation of tetracycline (TC) by peroxymonosulfate (PMS) activated with zero-valent iron (Fe0) was systematically studied through batches of experiments. First, effects of the key parameters (i.e., Fe0 dosage, PMS dosage, initial pH and co-existing ions) on TC degradation were investigated. Under the optimal conditions, high TC removal efficiency (88.5%) was achieved after 5 min treatment. Also, four control experiments were conducted to demonstrate the excellent performance of Fe0/PMS process and the synergistic effect between Fe0 and PMS. Compared with Fe2+ (the relatively common PMS activator), Fe0 was an efficient and long-lasting activator which consume less PMS and produce less dissolved iron ions. Then, the characteristics of reacted Fe0 particles were analyzed by SEM-EDS, XRD and XPS. The results shows that a few iron corrosion products generated and some of them deposited on the surface of reacted Fe0 particles. The generated iron corrosion products could promote PMS activation or adsorb TC directly. Next, the possible degradation pathway of TC was elaborated according to the intermediates detected by LC-QTOF-MS/MS and the toxicity in solution during reaction was evaluated. Finally, the common free radicals were monitored and the reaction mechanism was proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, J., & Wang, S. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.11.059 · Cited by 4,087
Rate Constants for Reactions of Inorganic Radicals in Aqueous Solution
Neta, P., Huie, R. E., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555808 · Cited by 3,651
Ghanbari, F., & Moradi, M. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.10.064 · Cited by 2,680
X-ray photoelectron spectroscopic studies of iron oxides
McIntyre, N. S., & Zetaruk, D. G. (1977) · Analytical Chemistry · doi:10.1021/ac50019a016 · Cited by 1,815
Influence of pH on the Formation of Sulfate and Hydroxyl Radicals in the UV/Peroxymonosulfate System
Guan, Y.-H., Ma, J., Li, X.-C., Fang, J.-Y., & Chen, L.-W. (2011) · Environmental Science & Technology · doi:10.1021/es2017363 · Cited by 1,338
Identification of Sulfate and Hydroxyl Radicals in Thermally Activated Persulfate
Liang, C., & Su, H.-W. (2009) · Industrial & Engineering Chemistry Research · doi:10.1021/ie9002848 · Cited by 1,301
Activation of peroxymonosulfate by base: Implications for the degradation of organic pollutants
Qi, C., Liu, X., Ma, J., Lin, C., Li, X., & Zhang, H. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.02.089 · Cited by 1,125
Rastogi, A., Al-Abed, S. R., & Dionysiou, D. D. (2009) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2008.07.010 · Cited by 1,112
Ji, L., Chen, W., Duan, L., & Zhu, D. (2009) · Environmental Science & Technology · doi:10.1021/es803268b · Cited by 801
Xu, Y., Ai, J., & Zhang, H. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.01.023 · Cited by 683
Photocatalytic degradation of tetracycline in aqueous solution by nanosized TiO2
Zhu, X.-D., Wang, Y.-J., Sun, R.-J., & Zhou, D.-M. (2013) · Chemosphere · doi:10.1016/j.chemosphere.2013.02.066 · Cited by 674
Halling-Sørensen, B., Sengeløv, G., & Tjørnelund, J. (2002) · Archives of Environmental Contamination and Toxicology · doi:10.1007/s00244-001-0017-2 · Cited by 625
Transition metal/UV-based advanced oxidation technologies for water decontamination
Anipsitakis, G. P., & Dionysiou, D. D. (2004) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2004.05.025 · Cited by 606
Tan, C., Gao, N., Deng, Y., Deng, J., Zhou, S., Li, J., & Xin, X. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.05.068 · Cited by 561
Persulfate Persistence under Thermal Activation Conditions
Johnson, R. L., Tratnyek, P. G., & Johnson, R. O. (2008) · Environmental Science & Technology · doi:10.1021/es8019462 · Cited by 508
Piumetti, M., Fino, D., & Russo, N. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.08.012 · Cited by 500
Quantification of the Oxidizing Capacity of Nanoparticulate Zero-Valent Iron
Joo, S. H., Feitz, A. J., Sedlak, D. L., & Waite, T. D. (2005) · Environmental Science & Technology · doi:10.1021/es048983d · Cited by 496
Lau, T. K., Chu, W., & Graham, N. J. D. (2007) · Environmental Science & Technology · doi:10.1021/es061395a · Cited by 451
Ao, X., & Liu, W. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.12.089 · Cited by 438
Aqueous photolysis of tetracycline and toxicity of photolytic products to luminescent bacteria
Jiao, S., Zheng, S., Yin, D., Wang, L., & Chen, L. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2008.05.042 · Cited by 437
Shukla, P. R., Wang, S., Sun, H., Ang, H. M., & Tadé, M. (2010) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2010.09.006 · Cited by 415
The Kinetics and Mechanism of the Decomposition of Caro's Acid. I
Ball, D. L., & Edwards, J. O. (1956) · Journal of the American Chemical Society · doi:10.1021/ja01587a011 · Cited by 396
Influences of carbonate and chloride ions on persulfate oxidation of trichloroethylene at 20 °C
Liang, C., Wang, Z.-S., & Mohanty, N. (2006) · Science of The Total Environment · doi:10.1016/j.scitotenv.2006.08.028 · Cited by 378
Barhoumi, N., Olvera-Vargas, H., Oturan, N., Huguenot, D., Gadri, A., Ammar, S., Brillas, E., & Oturan, M. A. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.03.034 · Cited by 376
Yin, R., Guo, W., Wang, H., Du, J., Zhou, X., Wu, Q., Zheng, H., Chang, J., & Ren, N. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.063 · Cited by 369
Huang, Y.-H., Huang, Y., Huang, C.-I., & Chen, C. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.05.091 · Cited by 364
Wang, Y., Cao, D., & Zhao, X. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.07.042 · Cited by 364
Yang, S., Wu, P., Liu, J., Chen, M., Ahmed, Z., & Zhu, N. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.04.175 · Cited by 360
Liu, Y., He, X., Fu, Y., & Dionysiou, D. D. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.11.043 · Cited by 357
Ji, Y., Shi, Y., Dong, W., Wen, X., Jiang, M., & Lu, J. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.04.028 · Cited by 348
Nefedov, V. I., Salyn, Y. V., Leonhardt, G., & Scheibe, R. (1977) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(77)85010-x · Cited by 344
Degradation and inactivation of tetracycline by TiO2 photocatalysis
Reyes, C., Fernández, J., Freer, J., Mondaca, M. A., Zaror, C., Malato, S., & Mansilla, H. D. (2006) · Journal of Photochemistry and Photobiology A: Chemistry · doi:10.1016/j.jphotochem.2006.04.007 · Cited by 328
Aqueous tetracycline degradation by H2O2 alone: Removal and transformation pathway
Chen, Y.-Y., Ma, Y.-L., Yang, J., Wang, L.-Q., Lv, J.-M., & Ren, C.-J. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.08.046 · Cited by 314
Zhou, T., Zou, X., Mao, J., & Wu, X. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2015.12.004 · Cited by 304
Wu, J., Zhang, H., Oturan, N., Wang, Y., Chen, L., & Oturan, M. A. (2012) · Chemosphere · doi:10.1016/j.chemosphere.2012.01.036 · Cited by 296
Lai, L., Yan, J., Li, J., & Lai, B. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.01.035 · Cited by 285
Self-citationTan, C., Dong, Y., Fu, D., Gao, N., Ma, J., & Liu, X. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.020 · Cited by 283
Jiang, X., Guo, Y., Zhang, L., Jiang, W., & Xie, R. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.02.034 · Cited by 281
Ji, F., Li, C., Wei, X., & Yu, J. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.07.053 · Cited by 265
Degradation of tetracycline in aqueous media by ozonation in an internal loop-lift reactor
Wang, Y., Zhang, H., Zhang, J., Lu, C., Huang, Q., Wu, J., & Liu, F. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.04.086 · Cited by 264
Oh, W.-D., Dong, Z., Ronn, G., & Lim, T.-T. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.11.056 · Cited by 263
Bicarbonate-activated persulfate oxidation of acetaminophen
Jiang, M., Lu, J., Ji, Y., & Kong, D. (2017) · Water Research · doi:10.1016/j.watres.2017.03.043 · Cited by 259
Qi, F., Chu, W., & Xu, B. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.08.113 · Cited by 257
Modeling of iron activated persulfate oxidation treating reactive azo dye in water matrix
Kušić, H., Peternel, I., Ukić, Š., Koprivanac, N., Bolanča, T., Papić, S., & Božić, A. L. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.05.076 · Cited by 225
Govindan, K., Raja, M., Noel, M., & James, E. J. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.02.036 · Cited by 225
Chen, H., Luo, H., Lan, Y., Dong, T., Hu, B., & Wang, Y. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.04.089 · Cited by 218
Assessment of the efficiency of photocatalysis on tetracycline biodegradation
Mboula, V. M., Hequet, V., Gru, Y., Colin, R., & Andrès, Y. (2012) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2012.01.032 · Cited by 211
Nasseri, S., Mahvi, A. H., Seyedsalehi, M., Yaghmaeian, K., Nabizadeh, R., Alimohammadi, M., & Safari, G. H. (2017) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2017.05.137 · Cited by 208
Aqueous tetracycline degradation by non-thermal plasma combined with nano-TiO2
He, D., Sun, Y., Xin, L., & Feng, J. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.07.089 · Cited by 207
Huang, Y., Huang, Y.-F., Huang, Y.-H., et al. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.12.138 · Cited by 197
Dalmázio, I., Almeida, M. O., Augusti, R., & Alves, T. M. A. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.12.001 · Cited by 194
XPS and FTIR spectroscopic study on microwave treated high phosphorus iron ore
Omran, M., Fabritius, T., Elmahdy, A. M., Abdel-Khalek, N. A., El-Aref, M., & Elmanawi, A. E.-H. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2015.03.209 · Cited by 192
Liu, X., Zhang, T., Zhou, Y., Fang, L., & Shao, Y. (2013) · Chemosphere · doi:10.1016/j.chemosphere.2013.08.090 · Cited by 182
Activating persulfate by Fe0 coupling with weak magnetic field: Performance and mechanism
Xiong, X., Sun, B., Zhang, J., Gao, N., Shen, J., Li, J., & Guan, X. (2014) · Water Research · doi:10.1016/j.watres.2014.05.042 · Cited by 180
Degradation of a xanthene dye by Fe(II)-mediated activation of Oxone process
Wang, Y. R., & Chu, W. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.12.033 · Cited by 178
Li, J., Liu, Q., Ji, Q. Q., & Lai, B. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.07.026 · Cited by 170
Self-citationYang, S., Xiao, T., Jun, Z., Chen, Y., & Li, L. (2015) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.01.022 · Cited by 154
Trichloroethylene Degradation by Zero Valent Iron Activated Persulfate Oxidation
Liang, C., & Lai, M.-C. (2008) · Environmental Engineering Science · doi:10.1089/ees.2007.0174 · Cited by 153
Ahmadi, M., & Ghanbari, F. (2018) · Materials Research Bulletin · doi:10.1016/j.materresbull.2018.10.027 · Cited by 136
Ultimate biodegradation and elimination of antibiotics in inherent tests
Gartiser, S., Urich, E., Alexy, R., & Kümmerer, K. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2006.08.038 · Cited by 134
Yang, Z., Dai, D., Yao, Y., Chen, L., Liu, Q., & Luo, L. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.04.018 · Cited by 132
Determination of antibiotic compounds in water by on-line SPE-LC/MSD
Choi, K.-J., Kim, S.-G., Kim, S.-G., Kim, C.-W., Kim, S.-H., & Kim, S.-H. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2006.07.037 · Cited by 129
Cherifi, Y., Addad, A., Vezin, H., Barras, A., Ouddane, B., Chaouchi, A., Szunerits, S., & Boukherroub, R. (2018) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2018.11.012 · Cited by 129
Ji, Q., Li, J., Xiong, Z., & Lai, B. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.12.128 · Cited by 125
Self-citationEffects of dissolved oxygen on dye removal by zero-valent iron
Wang, K.-S., Lin, C.-L., Wei, M., Liang, H.-H., Li, H.-C., Chang, C., Fang, Y.-T., & Chang, S. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.07.002 · Cited by 124
Yang, F., Huang, Y., Fang, C., et al. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.02.023 · Cited by 119
Wang, Y., Zhang, H., Chen, L., Wang, S., & Zhang, D. (2011) · Separation and Purification Technology · doi:10.1016/j.seppur.2011.06.035 · Cited by 109
Liu, Y., & Wang, Y. (2016) · AIChE Journal · doi:10.1002/aic.15503 · Cited by 105
Ultrasound enhanced catalytic ozonation of tetracycline in a rectangular air-lift reactor
Wang, Y., Zhang, H., & Chen, L. (2011) · Catalysis Today · doi:10.1016/j.cattod.2011.06.001 · Cited by 101
Electron efficiency of zero-valent iron for groundwater remediation and wastewater treatment
Liu, H., Wang, Q., Wang, C., & Li, X. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.11.010 · Cited by 95
Safari, G. H., Nasseri, S., Mahvi, A. H., Yaghmaeian, K., Nabizadeh, R., & Alimohammadi, M. (2015) · Journal of Environmental Health Science and Engineering · doi:10.1186/s40201-015-0234-7 · Cited by 94
Jaafarzadeh, N., Barzegar, G., & Ghanbari, F. (2017) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2017.08.012 · Cited by 87
Li, J., Ji, Q., Lai, B., & Yuan, D. (2017) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2017.09.002 · Cited by 80
Self-citationDegradation of azo dye with activated peroxygens: when zero-valent iron meets chloride
Wang, Z., Ai, L., Huang, Y., Zhang, J., Li, S., Chen, J., & Yang, F. (2017) · RSC Advances · doi:10.1039/c7ra03872k · Cited by 59
Keener, S. A., Wrbitzky, R., & Bader, M. (2006) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-006-0138-z · Cited by 39
Cited by
Xiao, S., Cheng, M., Zhong, H., Liu, Z., Liu, Y., Yang, X., & Liang, Q. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.123265 · Cited by 954
Xin, S., Liu, G., Ma, X., Gong, J., Ma, B., Yan, Q., Chen, Q., Ma, D., Zhang, G., Gao, M., et al. (2021) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2020.119386 · Cited by 567
Peng, X., Wu, J., Zhao, Z., Wang, X., Dai, H., Xu, L., Xu, G., Jian, Y., & Hu, F. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.130803 · Cited by 400
Insight on water remediation application using magnetic nanomaterials and biosorbents
Abdel Maksoud, M. I. A., Elgarahy, A. M., Farrell, C., Al-Muhtaseb, A. H., Rooney, D. W., & Osman, A. I. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.213096 · Cited by 374
Li, X., Cui, K., Guo, Z., Yang, T., Cao, Y., Xiang, Y., Chen, H., & Xi, M. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.122324 · Cited by 308
Metadata
- Authors
- Cao, J., Lai, L., Lai, B., Yao, G., Chen, X., & Song, L.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 364
- Pages
- 45-56
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2913204964
- Cited by
- 647
- References
- 75
- FWCI
- 28.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.