Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 311

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Biocompatible, self-wrinkled, antifreezing and stretchable hydrogel-based wearable sensor with PEDOT:sulfonated lignin as conductive materials

Wang, Qinhua, Pan, Xiaofeng, Lin, Changmei, Lin, Dezhi, Ni, Yonghao, Chen, Lihui, Huang, Liulian, Cao, Shilin, Ma, Xiaojuan·2019·Chemical Engineering Journal

Abstract

Abstract Gel-based strain sensors have great potential in the fields of motion detection and real-time healthcare. Nevertheless, the relatively low strain sensitivity and inferior anti-freezing property limit the utilization of these sensors. In this work, a novel multifunctional organohydrogel sensor was developed based on a poly (acrylic acid) (PAA) skeleton with poly (3,4-ethylenedioxythiophene): sulfonated lignin (PEDOT:SL) as the conductive material and a water/glycerol binary solvent as the dispersion medium. The conductive, self-wrinkled, soft and elastic properties endue the organohydrogel sensor with a superior gauge factor (GF) of up to 7 (strain: 100%), while the freezing tolerance of the water/glycerol solvent endows the organohydrogel with an excellent anti-freezing property. The organohydrogel sensor senses not only the movement of limbs, but also a weak pulse and throat vibrations. Moreover, physiological signals such as those used for electrocardiography (ECG) and electromyography (EMG) can be readily detected. In addition, the cell culture test shows that the organohydrogel is nontoxic, and the animal experiments demonstrate that the organohydrogel can protect skin from frostbite. Overall, this work presents a new concept to use lignin for conductive PEDOT polymerization and integrates the fabrication of conductive organohydrogel materials for precise strain sensing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2019.03.287

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 311

Metadata

Authors
Wang, Q., Pan, X., Lin, C., Lin, D., Ni, Y., Chen, L., Huang, L., Cao, S., & Ma, X.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2019-08
Volume
370
Pages
1039-1047
ISSN
1385-8947 (ISSN-L)
OpenAlex
W2934689771
Cited by
311
References
6
FWCI
13.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biocompatible, self-wrinkled, antifreezing and stretchable hydrogel-based wearable sensor with PEDOT:sulfonated lignin as conductive materials. https://app.cochat.ai/papers/10.1016/j.cej.2019.03.287
The paper
Wang, Q., Pan, X., Lin, C., Lin, D., Ni, Y., Chen, L., Huang, L., Cao, S., & Ma, X. (2019). Biocompatible, self-wrinkled, antifreezing and stretchable hydrogel-based wearable sensor with PEDOT:sulfonated lignin as conductive materials. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2019.03.287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.