Racial Bias in Pulse Oximetry Measurement Among Patients About to Undergo Extracorporeal Membrane Oxygenation in 2019-2020
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND Pulse oximeters may be less accurate in non-White patients. RESEARCH QUESTION Do pulse oximeter less effectively detect arterial hypoxemia in Black, Hispanic, and/or Asian patients than in White patients in respiratory failure about to initiate Extracorporeal Membrane Oxygenation (ECMO)? STUDY DESIGN AND METHODS Extracorporeal Life Support Organization (ELSO) Registry of adult patients with respiratory failure readings 6 hours prior to ECMO from 324 centers, January 2019 and July 2020. Our primary analysis was of rates of occult hypoxemia-low arterial oxygen saturation (SaO2 ≤ 88%) on arterial blood gas despite a pulse oximetry reading in the ranges of 92-96%. RESULTS The rate of pre-ECMO occult hypoxemia of SaO2 ≤ 88% was 10.2% (95%CI, 6.2%, 15.3%) for 186 White patients with SpO2 92-96%; 21.5% (95%CI, 11.3%, 35.3%) for 51 Black patients (p=0.031 vs White); 8.6% (95%CI 3.2%, 17.7%) for 70 Hispanic patients (p=0.693 vs White); and 9.2% (95%CI 3.5%, 19.0%) for 65 Asian patients (p=0.820 vs White). Black patients with respiratory failure had a statistically significantly higher risk of occult hypoxemia with an odds ratio (OR) of 2.57 (95%CI, 1.12, 5.92) compared to White patients (p=0.026). The risk of occult hypoxemia for Hispanic and Asian patients was equivalent to that of White patients. In a secondary analysis of patients with SaO2 ≤ 88% despite SpO2 >96%, Black patients had over three times the risk compared to White patients OR=3.52 (95% CI 1.12,11.10) p=0.032. INTERPRETATION Compared to White patients, prevalence of occult hypoxemia was higher in Black patients than in White patients about to undergo ECMO for respiratory failure, but comparable in Hispanic and Asian patients to White patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A simulation study of the number of events per variable in logistic regression analysis
Peduzzi, P., Concato, J., Kemper, E., Holford, T. R., & Feinstein, A. R. (1996) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(96)00236-3 · Cited by 9,655
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Racial bias in pulse oximetry measurement
Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2029240 · Cited by 1,114
Self-citationConservative Oxygen Therapy during Mechanical Ventilation in the ICU
The ICU-ROX Investigators and the Australian and New Zealand Intensive Care Society Clinical Trials Group (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1903297 · Cited by 511
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Feiner, J. R., Severinghaus, J. W., & Bickler, P. E. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000285988.35174.d9 · Cited by 400
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296
Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion
Louie, A., Feiner, J. R., Bickler, P. E., Rhodes, L., Bernstein, M., & Lucero, J. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002002 · Cited by 106
Critical care trainees call for pulse oximetry reform
Hidalgo, D. C., Olusanya, O., & Harlan, E. (2021) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(21)00102-8 · Cited by 21
Cited by
A New Global Definition of Acute Respiratory Distress Syndrome
Matthay, M. A., Arabi, Y., Arroliga, A. C., Bernard, G., Bersten, A. D., Brochard, L. J., Calfee, C. S., Combes, A., Daniel, B. M., Ferguson, N. D., et al. (2024) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202303-0558ws · Cited by 812
Fawzy, A., Wu, T. D., Wang, K., Robinson, M. L., Farha, J., Bradke, A., Golden, S. H., Xu, Y., & Garibaldi, B. T. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1906 · Cited by 326
“3%) had a total of 32 282 concurrently measured SpO2 and SaO2 levels during their hospital encounter, with a median (IQR) of 10 (2-30) measurements per patient.”
BackgroundShi, C., Goodall, M., Dumville, J., Hill, J., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · doi:10.1101/2022.02.16.22271062 · Cited by 158
Henry, N. R., Hanson, A. C., Schulte, P. J., Warner, N. S., Manento, M. N., Weister, T. J., & Warner, M. A. (2022) · Critical Care Medicine · doi:10.1097/ccm.0000000000005394 · Cited by 133
Valbuena, V. S. M., Seelye, S., Sjoding, M. W., Valley, T. S., Dickson, R. P., Gay, S. E., Claar, D., Prescott, H. C., & Iwashyna, T. J. (2022) · BMJ · doi:10.1136/bmj-2021-069775 · Cited by 127
Self-citation
Metadata
- Authors
- Valbuena, V. S. M., Barbaro, R. P., Claar, D., Valley, T. S., Dickson, R. P., Gay, S. E., Sjoding, M. W., & Iwashyna, T. J.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 2022-04
- Volume
- 161
- Issue
- 4
- Pages
- 971-978
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W3204102067
- Cited by
- 119
- References
- 12
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.