The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Solid-phase extraction combined with dispersive liquid–liquid microextraction-ultra preconcentration of chlorophenols in aqueous samples
Abstract
The solid-phase extraction (SPE) joined with the dispersive liquid-liquid microextraction (DLLME) has been developed as an ultra preconcentration technique for the determination of chlorophenols in water samples. Chlorophenols (CPs) were employed as model compounds to assess the extraction procedure and were determined by gas chromatography-electron-capture detection (GC-ECD). In solid-phase extraction-dispersive liquid-liquid microextraction (SPE-DLLME), CPs were adsorbed from a large volume of aqueous samples (100 mL) into 100 mg functionalized styrene-divinylbenzene polymer (PPL) sorbent. After the elution of the desired compounds from the sorbent by using acetone, DLLME technique was performed on the obtained solution. Some important extraction parameters, such as sample solution flow rate, breakthrough volume, sample pH, type and volume of the elution solvent as well as the salt addition, were studied and optimized. The new method (SPE-DLLME) provided an ultra enrichment factor (4390-17,870) for 19 CPs. The calibration graphs were linear in the range of 0.001-20 microg L(-1) and the limits of detection (LODs) ranged from 0.0005 to 0.1 microg L(-1). The relative standard deviations (RSDs, for 10.0 microg L(-1) of MCPs, 5.00 microg L(-1) of DCPs, 0.200 microg L(-1) of TCPs, 0.100 microg L(-1) of TeCPs and PCP) with and without the internal standard varied from 1.1 to 6.4% (n=7) and 2.5-9.7% (n=7), respectively. The relative recoveries of the well, tap and river water sampl…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Endocrine disrupters [10,18,57,59,80-83], antioxidants [62,84], PAHs [9,11,66,67,85,86] and other organic compounds of different natures [7,8,63, 87-104] have been analyzed by DLLME, IL-DLLME and DLLME-SFO.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [57]
In the citing paper
“Extraction recoveries were 2583%.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [57]
In the citing paper
“This combination of SPE and DLLME with GC-ECD provided enrichment factors of 4390-17870 and better LODs than other methods proposed in the literature (using SPE-GC-ECD, SPME-GC-MS and LPME-GC-MS), including another similar work developed by the same authors in which only DLLME was applied to extract the same group of chlorophenols from waters [79].”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [57]
In the citing paper
“It is worth mentioning the work of Fattahi et al . [57], in which 19 chlorophenols were analyzed by GC-ECD in water samples, combining SPE (with Bond Elute PPL sorbent) and DLLME.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [57]
In the citing paper
“This combination of SPE and DLLME with GC-ECD provided enrichment factors of 4390-17870”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [57]
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. B. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 5,007
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Self-citationSolvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Self-citationAnalytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. Κ. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 756
New trends in solid-phase extraction
Poole, C. F. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00605-8 · Cited by 718
He, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 682
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Optimization of solid-phase microextraction conditions for determination of phenols
Buchholz, K. D., & Pawliszyn, J. B. (1994) · Analytical Chemistry · doi:10.1021/ac00073a027 · Cited by 514
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Micelle-mediated separation and cloud-point extraction
Paleologos, E. K., Giokas, D. L., & Karayannis, M. I. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.01.013 · Cited by 484
Jahromi, E. Z., Bidari, A., Assadi, Y., Hosseini, M. R. M., & Jamali, M. R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.007 · Cited by 398
Self-citationDevelopments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Self-citationSample preparation for the analysis of volatile organic compounds in air and water matrices
Demeestere, K., Dewulf, J., Witte, B. D., & Langenhove, H. R. V. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.012 · Cited by 352
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Self-citationNagaraju, D., & Huang, S.-D. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.065 · Cited by 312
KOZANI, R., Assadi, Y., Shemirani, F., Hosseini, M. R. M., & Jamali, M. R. (2006) · Talanta · doi:10.1016/j.talanta.2006.10.039 · Cited by 264
Self-citationFarajzadeh, M. A., Bahram, M., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.040 · Cited by 234
Anodized Aluminum Wire as a Solid-Phase Microextraction Fiber
Djozan, D., Assadi, Y., & Haddadi, S. H. (2001) · Analytical Chemistry · doi:10.1021/ac0100188 · Cited by 214
Self-citationFariña, L., Boido, E., Carrau, F., & Dellacassa, E. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.006 · Cited by 209
Bagheri, H., Mir, A. A., & Babanezhad, E. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.10.040 · Cited by 200
Llompart, M., Lourido, M., Landı́n, P., Garcı́a-Jares, C., & Cela, R. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00646-5 · Cited by 186
Basheer, C., & Lee, H. K. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.083 · Cited by 183
Shokoufi, N., Shemirani, F., & Assadi, Y. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.009 · Cited by 183
Self-citationPeñalver, A., Pocurull, E., Borrull, F., & Marcé, R. M. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00113-9 · Cited by 180
Zhao, L., & Lee, H. K. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01199-2 · Cited by 131
Kozani, R. R., Assadi, Y., Shemirani, F., Hosseini, M. R. M., & Jamali, M. R. (2007) · Chromatographia · doi:10.1365/s10337-007-0226-6 · Cited by 128
Self-citationBagheri, H., & Saraji, M. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01972-6 · Cited by 128
Determination of phenols by solid-phase microextraction
Barták, P., & Čáp, L. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(96)01090-4 · Cited by 126
Single-drop microextraction for the analysis of organophosphorous insecticides in water
Lambropoulou, D. A., Psillakis, E., Albanis, T. A., & Kalogerakis, N. E. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.03.055 · Cited by 114
Bagheri, H., & Saraji, M. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)01165-1 · Cited by 110
Rodríguez, I., Turnes, M. I., Mejuto, M. C., & Cela, R. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00795-4 · Cited by 105
Homogeneous liquid–liquid extraction of trace amounts of mononitrotoluenes from waste water samples
Ebrahimzadeh, H., Yamini, Y., Kamarei, F., & Shariati, S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.05.013 · Cited by 91
Modified Pencil Lead as a New Fiber for Solid-Phase Microextraction
Djozan, D., & Assadi, Y. (2004) · Chromatographia · doi:10.1365/s10337-004-0368-8 · Cited by 83
Self-citationAguilar, C., Ferrer, I., Borrull, F., Marcé, R. M., & Barceló, . (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00033-1 · Cited by 75
Djozan, D., & Assadi, Y. (1999) · Microchemical Journal · doi:10.1006/mchj.1999.1791 · Cited by 70
Self-citationPuig, D., & Barceló, . (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00188-6 · Cited by 67
Djozan, D., & Assadi, Y. (1997) · Chromatographia · doi:10.1007/bf02505558 · Cited by 65
Self-citationJáuregui, O., Moyano, E., & Galcerán, M. T. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00653-5 · Cited by 64
Igarashi, S., Takahashi, A., Ueki, Y., & Yamaguchi, H. (2000) · The Analyst · doi:10.1039/b001581o · Cited by 56
Determination of phenol and monochlorophenols in water by reversed-phase liquid chromatography
Makuch, B., Gazda, K., & Kamiśnski, M. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)80007-8 · Cited by 55
Crespı́n, M. A., Gallego, M., & Valcárcel, M. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00012-0 · Cited by 52
Saito, Y., Ueta, I., Ogawa, M., Hayashida, M., & Jinno, K. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.011 · Cited by 51
Modified copper wire as solid-phase microextraction fiber, selective extraction of some amines
Djozan, D., Assadi, Y., & Karim‐Nezhad, G. (2002) · Chromatographia · doi:10.1007/bf02497678 · Cited by 44
Self-citationAzevedo, D. A., Lacorte, S., Viana, P. C., & Barceló, . (2000) · Chromatographia · doi:10.1007/bf02491556 · Cited by 44
Takagai, Y., & Igarashi, S. (2001) · The Analyst · doi:10.1039/b102079j · Cited by 37
Oshite, S., Furukawa, M., & Igarashi, S. (2001) · The Analyst · doi:10.1039/b100114k · Cited by 37
Research works printed but not linked: 2
- Djozan, 2004, Chromatographia, 60, 313
- A. Bidari, E. Zeini Jahromi, Y. Assadi, M.R. Milani Hosseini, Microchem. J., in press.
Cited by
Sorted by citations
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476
Liu, Q. S., Shi, J., Sun, J., Wang, T., Zeng, L., & Jiang, G. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201007138 · Cited by 415
Methodologies for the Extraction of Phenolic Compounds from Environmental Samples: New Approaches
Santana, C. M., Sosa‐Ferrera, Z., Torres-Padrón, M. E., & Santana‐Rodríguez, J. J. (2009) · Molecules · doi:10.3390/molecules14010298 · Cited by 300
Metadata
- Authors
- Fattahi, N., Samadi, S., Assadi, Y., & Hosseini, M. R. M.
- Affiliations
- Iran University of Science and Technology (IR)
- Corresponding author
- Assadi, Yaghoub
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2007-10
- Volume
- 1169
- Issue
- 1-2
- Pages
- 63-69
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2087588327
- Cited by
- 178
- References
- 48
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 6 · 2019: 6 · 2018: 9 · 2017: 8 · 2016: 10 · 2015: 8 · 2014: 24 · 2013: 14 · 2012: 13
- FWCI
- 17.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Iran University of Science and Technology
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Keywords
- chlorophenols, solid-phase extraction, dispersive liquid-liquid microextraction, water analysis, extraction optimization, electron capture detection
- MeSH terms
- Adsorption, Chlorophenols, Chromatography, Gas, Chemical Fractionation, Polystyrenes, Reference Standards, Sensitivity and Specificity, Specimen Handling, Spectrophotometry, Atomic, Water Pollutants, Chemical, Water Supply, Reproducibility of Results, Rivers, Solid Phase Extraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review