CoChat

Ultrasound leaching–dispersive liquid–liquid microextraction based on solidification of floating organic droplet for determination of polybrominated diphenyl ethers in sediment samples by gas chromatography–tandem mass spectrometry

Open access
Lana, Nerina B., Berton, Paula, Covaci, Adrian, Atencio, Adrián G., Ciocco, Néstor F., Altamirano, Jorgelina C. · 2013 · Journal of Chromatography A
Cited by 42

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Ultrasound leaching-dispersive liquid-liquid microextraction using solidification of floating organic droplet (USL-DLLME-SFO) technique is proposed for extraction and isolation of polybrominated diphenyl ethers (PBDEs) from sediment and further determination by gas chromatography-tandem mass spectrometry (GC-MS/MS). Parameters that affect the efficiency of the procedure were investigated by a full factorial (2(k)) screening design. Variables showing significant effects on the analytical responses were considered within a further central composite design (CCD). The optimization assays have led to following protocol: ultrasound assisted lixiviation of 1g sediment was carried out by using 1.2 mL MeOH. Further, the analytes were isolated from 0.4 mL of the extract using the DLLME-SFO technique. The microextraction was performed using 0.1 mL MeOH, 22 mg 1-dodecanol, 1 mL NaCl solution 6.15M and 4.4 mL ultrapure water as dispersive and extracting solvents, medium ionic strength and dispersant bulk, respectively. Under optimum conditions, the method exhibits good performance in terms of linearity and precision (RSD<9.2%), with recoveries above 71% and limits of detection (LODs) within the range 0.5-1.8 pgg(-1) dry weight (d.w.). Method validation was demonstrated through the analysis of environmental sediment samples in which PBDEs were detected and quantified. The presence of BDE-47, -100, -99 and -153 was reported within the concentration range of <LOD to 29 pgg(-1) d.w. The proposed methodology constitutes a suitable approach for the analysis of PBDEs in complex solid samples requires minimum organic solvents consumption, sample manipulation, and increases sample throughput.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2013.02.027

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 42

Metadata

Authors
Lana, N. B., Berton, P., Covaci, A., Atencio, A. G., Ciocco, N. F., & Altamirano, J. C.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2013-04
Volume
1285
Pages
15-21
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2020435767
Cited by
42
References
9
FWCI
6.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.