The DOI matches its Crossref record; 47 of the 49 references it cites were found in a registry or an index.
A novel P300-based brain–computer interface stimulus presentation paradigm: Moving beyond rows and columns
Open accessAbstract
Objective An electroencephalographic brain-computer interface (BCI) can provide a non-muscular means of communication for people with amyotrophic lateral sclerosis (ALS) or other neuromuscular disorders. We present a novel P300-based BCI stimulus presentation - the checkerboard paradigm (CBP). CBP performance is compared to that of the standard row/column paradigm (RCP) introduced by Farwell and Donchin (1988).Methods Using an 8x9 matrix of alphanumeric characters and keyboard commands, 18 participants used the CBP and RCP in counter-balanced fashion. With approximately 9-12 min of calibration data, we used a stepwise linear discriminant analysis for online classification of subsequent data.Results Mean online accuracy was significantly higher for the CBP, 92%, than for the RCP, 77%. Correcting for extra selections due to errors, mean bit rate was also significantly higher for the CBP, 23 bits/min, than for the RCP, 17 bits/min. Moreover, the two paradigms produced significantly different waveforms. Initial tests with three advanced ALS participants produced similar results. Furthermore, these individuals preferred the CBP to the RCP.Conclusions These results suggest that the CBP is markedly superior to the RCP in performance and user acceptability.Significance The CBP has the potential to provide a substantially more effective BCI than the RCP. This is especially important for people with severe neuromuscular disabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“EEG spellers based on oddball potentials or motor imagery typically achieve 1–5 characters per minute28–32.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [30]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Draper, N. R., & Smith, H. (2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,993
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationUpdating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,129
Self-citationApplied Regression Analysis (2nd ed).
de Carvalho, J. F., Draper, N. R., & Smith, H. (1981) · Journal of the American Statistical Association · doi:10.2307/2287608 · Cited by 3,054
Clarke, G. M., Draper, N. R., & Smith, H. (1982) · Journal of the Royal Statistical Society Series A (General) · doi:10.2307/2982106 · Cited by 1,797
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Self-citationOn Quantifying Surprise: The Variation of Event‐Related Potentials With Subjective Probability
Duncan‐Johnson, C. C., & Donchin, E. (1977) · Psychophysiology · doi:10.1111/j.1469-8986.1977.tb01312.x · Cited by 1,235
Flagged first, then by citations
2 of the 49 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- Allison BZ. P3 or not P3: toward a better P300 BCI. PhD dissertation, University of California, San Diego, CA; 2003.
- Sharbrough, 1991, AEEGS guidelines for standard electrode position nomenclature, Clin Neurophysiol, 8, 202
Cited by
Sorted by citations
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
High-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 999
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 695
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
“Similarly, information transfer rates are also a meaningful point of comparison, though they are less reflective of practical communication rates than bitrate (which takes into account the need to correct errors; detailed in Nuyujukian et al. (2015) ; Townsend et al. (2010) ).”
BackgroundBrain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 541
Self-citationRashid, M., Sulaiman, N., Majeed, A. P. P. A., Musa, R. M., Nasir, A. F. A., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 545
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
A brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400
Self-citationBrain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F. W., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 390
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 382
Self-citationLazarou, I., Nikolopoulos, S., Petrantonakis, P. C., Kompatsiaris, I. Y., & Tsolaki, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00014 · Cited by 351
Flashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 308
Sparse Bayesian Classification of EEG for Brain–Computer Interface
Zhang, Y., Zhou, G., Jin, J., Zhao, Q., Wang, X., & Cichocki, A. S. (2015) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2015.2476656 · Cited by 264
A Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 259
Brain–Computer Interface Technologies in the Coming Decades
Lance, B. J., Kerick, S. E., Ries, A. J., Oie, K. S., & McDowell, K. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184830 · Cited by 231
Xu, M., Xiao, X., Wang, Y., Qi, H., Jung, T., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 228
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 226
Huggins, J. E., Wren, P. A., & Gruis, K. L. (2011) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482968.2011.572978 · Cited by 215
Wolpaw, J. R. (2013) · Handbook of clinical neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 231
Self-citationHramov, A. E., Александрович, М. В., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 228
Toward Brain-Actuated Humanoid Robots: Asynchronous Direct Control Using an EEG-Based BCI
Chae, Y., Jeong, J., & Jo, S. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2201310 · Cited by 211
Mak, J. N., Arbel, Y., Minett, J. W., McCane, L. M., Yuksel, B. F., Ryan, D. B., Thompson, D. E., Bianchi, L., & Deniz Erdogmus, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025003 · Cited by 195
Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces
Guger, C., Krausz, G., Allison, B. Z., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00060 · Cited by 201
Muenssinger, J., Halder, S., Kleih, S. C., Furdea, A., Raco, V., Hösle, A., & Kübler, A. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00182 · Cited by 175
Spelling with non-invasive Brain–Computer Interfaces – Current and future trends
Cecotti, H. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.08.003 · Cited by 177
A Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
Xu, M., Han, J. H., Wang, Y., Jung, T., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975614 · Cited by 165
Yuan, P., Gao, X., Allison, B. Z., Wang, Y., Bin, G., & Gao, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026014 · Cited by 171
An adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 161
Self-citationA novel BCI based on ERP components sensitive to configural processing of human faces
Zhang, Y., Zhao, Q., Jin, J., Wang, X., & Cichocki, A. S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026018 · Cited by 157
Gaze-independent BCI-spelling using rapid serial visual presentation (RSVP)
Acqualagna, L., & Blankertz, B. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.12.050 · Cited by 156
Jin, J., Allison, B. Z., Kaufmann, T., Kübler, A., Zhang, Y., Wang, X., & Cichocki, A. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049688 · Cited by 152
Application of BCI systems in neurorehabilitation: a scoping review
Bamdad, M., Zarshenas, H., & Auais, M. A. (2015) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2014.961569 · Cited by 150
Objective and Subjective Evaluation of Online Error Correction during P300-Based Spelling
Perrin, M., Maby, E., Daligault, S., Bertrand, O., & Mattout, J. (2012) · Advances in Human-Computer Interaction · doi:10.1155/2012/578295 · Cited by 149
Enhance decoding of pre-movement EEG patterns for brain–computer interfaces
Wang, K., Xu, M., Wang, Y., Zhang, S., Chen, L., & Ming, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab598f · Cited by 146
Spatial-Temporal Discriminant Analysis for ERP-Based Brain-Computer Interface
Zhang, Y., Zhou, G., Zhao, Q., Jin, J., Wang, X., & Cichocki, A. S. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2243471 · Cited by 145
He, B., Yuan, H., Meng, J., & Gao, S. (2020) · Springer eBooks · doi:10.1007/978-3-030-43395-6_4 · Cited by 150
Predictive Spelling With a P300-Based Brain–Computer Interface: Increasing the Rate of Communication
Ryan, D. B., Frye, G. E., Townsend, G., Berry, D. R., Mesa-G, S., Gates, N. A., & Sellers, E. W. (2010) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2011.535754 · Cited by 142
Self-citationMcCane, L. M., Heckman, S. M., McFarland, D. J., Townsend, G., Mak, J. N., Sellers, E. W., Zeitlin, D., Tenteromano, L. M., Wolpaw, J. R., & Vaughan, T. M. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.01.013 · Cited by 141
Self-citationThe Asilomar Survey: Stakeholders’ Opinions on Ethical Issues Related to Brain-Computer Interfacing
Nijboer, F., Clausen, J., Allison, B. Z., & Haselager, P. (2011) · Neuroethics · doi:10.1007/s12152-011-9132-6 · Cited by 144
Pires, G., Nunes, U., & Castelo-Branco, M. S. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.11.016 · Cited by 135
A hybrid BCI speller paradigm combining P300 potential and the SSVEP blocking feature
Xu, M., Qi, H., Wan, B., Yin, T., Liu, Z., & Ming, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026001 · Cited by 134
Brain-Computer Interface Controlled Functional Electrical Stimulation System for Ankle Movement
Do, A. H., Wang, P. T., King, C., Abiri, A., & Nenadić, Z. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-49 · Cited by 134
A P300 Brain–Computer Interface Based on a Modification of the Mismatch Negativity Paradigm
Jin, J., Sellers, E. W., Zhou, S., Zhang, Y., Wang, X., & Cichocki, A. S. (2015) · International Journal of Neural Systems · doi:10.1142/s0129065715500112 · Cited by 133
Self-citationBrain–Computer Interface after Nervous System Injury
Burns, A., Adeli, H., & Buford, J. A. (2014) · The Neuroscientist · doi:10.1177/1073858414549015 · Cited by 132
Brain-computer interface (BCI) evaluation in people with amyotrophic lateral sclerosis
McCane, L. M., Sellers, E. W., McFarland, D. J., Mak, J. N., Carmack, C. S., Zeitlin, D., Wolpaw, J. R., & Vaughan, T. M. (2014) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.3109/21678421.2013.865750 · Cited by 132
Self-citationBrain-Computer Interface: Current and Emerging Rehabilitation Applications
Daly, J. J., & Huggins, J. E. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2015.01.007 · Cited by 124
The P300-based brain–computer interface (BCI): Effects of stimulus rate
McFarland, D. J., Sarnacki, W. A., Townsend, G., Vaughan, T. M., & Wolpaw, J. R. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.029 · Cited by 124
Self-citationImplementing a calibration-free SSVEP-based BCI system with 160 targets
Chen, Y., Yang, C., Ye, X., Chen, X., Wang, Y., & Gao, X. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0bfa · Cited by 121
Jin, J., Allison, B. Z., Zhang, Y., Wang, X., & Cichocki, A. S. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500270 · Cited by 112
An efficient word typing P300-BCI system using a modified T9 interface and random forest classifier
Akram, F., Han, S. M., & Kim, T. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.10.021 · Cited by 107
Comparison of Classification Methods for P300 Brain-Computer Interface on Disabled Subjects
Manyakov, N. V., Chumerin, N., Combaz, A., & Hulle, M. M. V. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/519868 · Cited by 107
An Auditory-Tactile Visual Saccade-Independent P300 Brain–Computer Interface
Yin, E., Zeyl, T. J., Saab, R., Hu, D., Zhou, Z., & Chau, T. T. (2015) · International Journal of Neural Systems · doi:10.1142/s0129065716500015 · Cited by 105
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0689-8 · Cited by 105
Self-citationPires, G., Nunes, U., & Castelo-Branco, M. S. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.10.040 · Cited by 103
Barriers to and mediators of brain–computer interface user acceptance: focus group findings
Blain‐Moraes, S., Schaff, R., Gruis, K. L., Huggins, J. E., & Wren, P. A. (2012) · Ergonomics · doi:10.1080/00140139.2012.661082 · Cited by 102
Noninvasive Brain–Computer Interfaces for Augmentative and Alternative Communication
Akçakaya, M., Peters, B., Moghadamfalahi, M., Mooney, A. R., Orhan, U., Oken, B., Deniz Erdogmus, B., & Fried-Oken, M. B. (2014) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2295097 · Cited by 105
Review of real brain-controlled wheelchairs
Fernández-Rodríguez, Á., Velasco-Álvarez, F., & Ron-Angevín, R. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061001 · Cited by 102
Review of brain encoding and decoding mechanisms for EEG-based brain–computer interface
Xu, L., Xu, M.-P., Jung, T., & Dong, M. (2021) · Cognitive Neurodynamics · doi:10.1007/s11571-021-09676-z · Cited by 90
Huggins, J. E., Moinuddin, A. A., Chiodo, A. E., & Wren, P. A. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.05.028 · Cited by 97
Kaufmann, T., Völker, S., Gunesch, L., & Kübler, A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00072 · Cited by 98
A novel P300 BCI speller based on the Triple RSVP paradigm
Lin, Z., Zhang, C., Zeng, Y., Tong, L., & Yan, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-21717-y · Cited by 99
Kindermans, P.-J., Tangermann, M., Müller, K., & Schrauwen, B. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035005 · Cited by 98
Electroencephalography ( EEG )‐Based Brain–Computer Interfaces
Lotte, F., Bougrain, L., & Clerc, M. (2015) · Wiley eBooks · doi:10.1002/047134608x.w8278 · Cited by 111
Mak, J. N., McFarland, D. J., Vaughan, T. M., McCane, L. M., Tsui, P. Z., Zeitlin, D., Sellers, E. W., & Wolpaw, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026014 · Cited by 98
Self-citationAn Efficient ERP-Based Brain-Computer Interface Using Random Set Presentation and Face Familiarity
Yeom, S.-K., Fazli, S., Müller, K., & Lee, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111157 · Cited by 96
Is It Significant? Guidelines for Reporting BCI Performance
Billinger, M., Daly, I. P., Kaiser, V., Jin, J., Allison, B. Z., Müller-Putz, G., & Brunner, C. (2012) · Biological and medical physics series · doi:10.1007/978-3-642-29746-5_17 · Cited by 97
An Asynchronous Hybrid Spelling Approach Based on EEG–EOG Signals for Chinese Character Input
Yu, Y., Liu, Y., Yin, E., Jiang, J., Zhou, Z., & Hu, D. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2914916 · Cited by 95
EEG-Based Detection of Driver Emergency Braking Intention for Brain-Controlled Vehicles
Teng, T., Bi, L., & Liu, Y. (2017) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2017.2740427 · Cited by 94
Li, M., He, D., Li, C., & Qi, S. (2021) · Brain Sciences · doi:10.3390/brainsci11040450 · Cited by 101
Jin, J., Allison, B. Z., Wang, X., & Neuper, C. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.01.004 · Cited by 94
The Body-Machine Interface: A New Perspective on an Old Theme
Casadio, M., Ranganathan, R., & Mussa-Ivaldi, F. A. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.700968 · Cited by 100
Out of the frying pan into the fire—the P300-based BCI faces real-world challenges
Kleih, S. C., Kaufmann, T., Zickler, C., Halder, S., Leotta, F., Cincotti, F., Aloise, F., Riccio, A., Herbert, C., Mattia, D., et al. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00019-4 · Cited by 93
Age-related differences in SSVEP-based BCI performance
Volosyak, I., Gembler, F. W., & Stawicki, P. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.08.121 · Cited by 90
An optimized ERP brain–computer interface based on facial expression changes
Jin, J., Daly, I. P., Zhang, Y., Wang, X., & Cichocki, A. S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036004 · Cited by 89
Lakey, C. E., Berry, D. R., & Sellers, E. W. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025019 · Cited by 84
Self-citationA Brain–Computer Interface-Based Vehicle Destination Selection System Using P300 and SSVEP Signals
Fan, X., Bi, L., Teng, T., Ding, H., & Liu, Y. (2014) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2014.2330000 · Cited by 86
User-centered design in brain–computer interfaces—A case study
Schreuder, M., Riccio, A., Risetti, M., Dähne, S., Ramsay, A., Williamson, J. H., Donatella Mattia, A., & Tangermann, M. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.07.005 · Cited by 86
Amaral, C. P., Simões, M. A., Mouga, S., Andrade, J., & Castelo-Branco, M. S. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.07.029 · Cited by 90
Clinical evaluation of BrainTree, a motor imagery hybrid BCI speller
Perdikis, S., Leeb, R., Williamson, J., Ramsay, A., Tavella, M., Desideri, L., Hoogerwerf, E.-J., Al-Khodairy, A., Murray-Smith, R., & Millán, J. D. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036003 · Cited by 85
He, B., Gao, S., Yuan, H., & Wolpaw, J. R. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_2 · Cited by 86
Self-citationUpper Body-Based Power Wheelchair Control Interface for Individuals With Tetraplegia
Thorp, E. B., Abdollahi, F., Chen, D., Farshchiansadegh, A., Lee, M.-H., Pedersen, J. P., Pierella, C., Roth, E. J., Seáñez, I., & Mussa-Ivaldi, F. A. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2439240 · Cited by 82
Carabalona, R., Grossi, F., Tessadri, A., Castiglioni, P., Caracciolo, A., & Munari, I. D. (2012) · Ergonomics · doi:10.1080/00140139.2012.661083 · Cited by 81
The science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaïa, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 79
Brain–computer interfacing in disorders of consciousness
Chatelle, C., Chennu, S., Noirhomme, Q., Cruse, D., Owen, A. M., & Laureys, S. (2012) · Brain Injury · doi:10.3109/02699052.2012.698362 · Cited by 86
Incorporation of dynamic stopping strategy into the high-speed SSVEP-based BCIs
Jiang, J., Yin, E., Wang, C., Xu, M., & Ming, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac605 · Cited by 78
Double ErrP Detection for Automatic Error Correction in an ERP-Based BCI Speller
Cruz, A., Pires, G., & Nunes, U. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2755018 · Cited by 77
30+ years of P300 brain–computer interfaces
Allison, B. Z., Kübler, A., & Jin, J. (2020) · Psychophysiology · doi:10.1111/psyp.13569 · Cited by 81
An Asynchronous P300-Based Brain-Computer Interface Web Browser for Severely Disabled People
Martínez-Cagigal, V., Gómez‐Pilar, J., Álvarez, D., & Hornero, R. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2623381 · Cited by 76
Käthner, I., Kübler, A., & Halder, S. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0071-z · Cited by 75
Brain–computer interfaces in amyotrophic lateral sclerosis: A metanalysis
Marchetti, M., & Priftis, K. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.09.017 · Cited by 77
Playing Tetris with non-invasive BCI
Pires, G., Torres, M. A., Casaleiro, N., Nunes, U., & Castelo-Branco, M. S. (2011) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah.2011.6165454 · Cited by 73
An improved P300 pattern in BCI to catch user’s attention
Jin, J., Zhang, H., Daly, I. P., Wang, X., & Cichocki, A. S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6213 · Cited by 72
Natural language processing with dynamic classification improves P300 speller accuracy and bit rate
Speier, W. F., Arnold, C. W., Lu, J., Taira, R. K., & Pouratian, N. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016004 · Cited by 71
Combaz, A., Chatelle, C., Robben, A., Vanhoof, G., Goeleven, A., Thijs, V., Hulle, M. M. V., & Laureys, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073691 · Cited by 71
A Multimodal Gaze-Controlled Virtual Keyboard
Cecotti, H. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2537749 · Cited by 71
Increasing BCI communication rates with dynamic stopping towards more practical use: an ALS study
Mainsah, B. O., Collins, L. M., Colwell, K. A., Sellers, E. W., Ryan, D. B., Caves, K. M., & Throckmorton, C. S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016013 · Cited by 69
Self-citationA New Generation of Brain-Computer Interface Based on Riemannian Geometry
Congedo, M., Barachant, A., & Andreev, A. (2013) · arXiv · doi:10.48550/arxiv.1310.8115 · Cited by 69
Prediction of Auditory and Visual P300 Brain-Computer Interface Aptitude
Halder, S., Hammer, E. M., Kleih, S. C., Bogdan, M., Rosenstiel, W., Birbaumer, N., & Kübler, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053513 · Cited by 67
Metadata
- Authors
- Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W.
- Affiliations
- Algoma University (CA)
- New York State Department of Health (US)
- University of North Florida (US)
- East Tennessee State University (US)
- Corresponding author
- Sellers, E.W.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 121
- Issue
- 7
- Pages
- 1109-1120
- ISSN
- 1388-2457 (ISSN-L)
- PMC
- PMC2879474
- OpenAlex
- W2158655338
- Cited by
- 570
- References
- 49
- Citations by year
- 2026: 6 · 2025: 14 · 2024: 17 · 2023: 17 · 2022: 23 · 2021: 36 · 2020: 39 · 2019: 35 · 2018: 41 · 2017: 42 · 2016: 40 · 2015: 47 · 2014: 60 · 2013: 51 · 2012: 47
- FWCI
- 29.48
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Digital Commons - East Tennessee State University (East Tennessee State University) (submittedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (EB 00856, R01EB000856)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD030146, HD30146)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- P300, brain-computer interface, amyotrophic lateral sclerosis, neuromuscular disorders, communication aids, data rate, linear discriminant analysis, user acceptance
- MeSH terms
- Brain, Electroencephalography, Female, Humans, Male, Nervous System Diseases, Pattern Recognition, Visual, Photic Stimulation, User-Computer Interface, Event-Related Potentials, P300
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review