Effect of EEG electrode number on epileptic source localization in pediatric patients
Open accessAbstract
Objective To investigate the relationship between EEG source localization and the number of scalp EEG recording channels.Methods 128 EEG channel recordings of 5 pediatric patients with medically intractable partial epilepsy were used to perform source localization of interictal spikes. The results were compared with surgical resection and intracranial recordings. Various electrode configurations were tested and a series of computer simulations based on a realistic head boundary element model were also performed in order to further validate the clinical findings.Results The improvement seen in source localization substantially decreases as the number of electrodes increases. This finding was evaluated using the surgical resection, intracranial recordings and computer simulation. It was also shown in the simulation that increasing the electrode numbers could remedy the localization error of deep sources. A plateauing effect was seen in deep and superficial sources with further increasing the electrode number.Conclusion The source localization is improved when electrode numbers increase, but the absolute improvement in accuracy decreases with increasing electrode number.Significance Increasing the electrode number helps decrease localization error and thus can more ably assist the physician to better plan for surgical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Studies indicate that higher spatial sampling helps improve the precision of ESI (18, 19).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details.
Pascual-Marqui, R. D. (2002) · PubMed · Cited by 3,329
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Baillet, S., Mosher, J., & Leahy, R. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,846
Michel, C., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & de Peralta, R. G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,771
Electric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA · doi:10.1001/jama.1982.03320380071046 · Cited by 1,557
Surgical treatment of the epilepsies
Bloomfield, S. M., & Shetter, A. G. (1988) · Surgical Neurology · doi:10.1016/0090-3019(88)90022-5 · Cited by 1,206
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Spatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 756
Cited by
Sorted by citations
Items 101–148 of 148
Limotai, C., Mokklaew, J., Sukaem, B., Jirasakuldej, S., Prakkamakul, S., Tepmongkol, S., & Bunyaratavej, K. (2023) · Journal of neurosurgery · doi:10.3171/2023.6.jns222695 · Cited by 3
Effects of EEG Electrode Numbers on Deep Learning-Based Source Imaging
Rong, J., Sun, R., Guo, Y., & He, B. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-43075-6_11 · Cited by 2
Self-citationNucera, B., Perulli, M., Alvisi, L., Bisulli, F., Bonanni, P., Canafoglia, L., Cantalupo, G., Ferlazzo, E., Granvillano, A., Mecarelli, O., et al. (2023) · Neurological Sciences · doi:10.1007/s10072-023-07159-z · Cited by 3
“High-density EEG (hdEEG) is a tool that allows the localization of EEG cortical sources with higher accuracy compared to standard recordings [1].”
Ren, X., White, E. J., Kuplicki, R., Paulus, M. P., Ironside, M., Aupperle, R. L., & Stewart, J. L. (2025) · Biological Psychiatry Cognitive Neuroscience and Neuroimaging · doi:10.1016/j.bpsc.2025.02.001 · Cited by 3
Determination of the Optimal Electrode Selection for Motor Imaginary Classification with EEGNet
Sangbamrung, I., Kanjanawattana, S., & Bhakdisongkhram, G. (2024) · International Conference on Computer Technology Applications (ICCTA) · doi:10.1145/3674558.3674567 · Cited by 2
Revolutionizing brain–computer interfaces: Compact and high-speed wireless neural signal acquisition
Liu, M., Guo, X., Cao, L., Cui, H., Li, Z., Lin, Y., Yin, Z., Quan, W., Feng, C., Ma, T., et al. (2025) · Review of Scientific Instruments · doi:10.1063/5.0287033 · Cited by 2
Complexity reduction techniques in music-based EEG source localization
Safavi, S. M., Lee, S., Lopour, B. A., & Chou, P. H. (2016) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2016.7906018 · Cited by 2
Aberrant hyperfocusing in schizophrenia indicated by elevated theta phase-gamma amplitude coupling
An, S.-J., Choi, S., Hwang, J. S., Park, S., Jang, M., Kim, M., & Kwon, J. S. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.11.012 · Cited by 2
Effect of EEG Electrode Numbers on Source Estimation in Motor Imagery
Yazıcı, M., Ulutaş, M., & Okuyan, M. (2025) · Brain Sciences · doi:10.3390/brainsci15070685 · Cited by 2
“When EEG source analysis studies are examined, it has been demonstrated that a small number of electrodes may cause errors in the source analysis, and the use of at least 64 EEG electrodes can result in higher accuracy in source analysis [29–33].”
Kumar, S., Sharma, A. K., Mamun, K. A., & Tsunoda, T. (2015) · Asia-Pacific World Congress on Computer Science and Engineering (APWC on CSE) · doi:10.1109/apwccse.2015.7476214 · Cited by 2
“The major focus and emphasis of BCI research is in the field of biomedical engineering [11-15].”
BackgroundOchoa, J. G., Rini, J. F., Diaz, J., & Botwell, J. (2019) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000557 · Cited by 2
Babiloni, C., Percio, C. D., Lizio, R., Lopez, S., Pennica, A., Roma, P., Correr, V., Cucciolla, F., Toma, G., Soricelli, A., et al. (2022) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2022.01.015 · Cited by 2
Friedrich, E. V. C., Zillekens, I. C., Biel, A. L., O’Leary, D., Singer, J., Seegenschmiedt, E. V., Sauseng, P., & Schilbach, L. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15903 · Cited by 2
Electroencephalogram-based brain–computer interface systems for controlling rehabilitative devices
Tarafdar, K. K., Pradhan, B. K., Nayak, S. K., Khasnobish, A., Bhattacharyya, S., & Pal, K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102420-1.00041-8 · Cited by 2
Bruña, R., Cuesta, P., Ramírez‐Toraño, F., Suárez‐Méndez, I., & Pereda, E. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.01.19.524740 · Cited by 2
Effect of analytical variability in estimating EEG-based functional connectivityPreprint
Allouch, S., Kabbara, A., Duprez, J., Paban, V., Khalil, M. A., Modolo, J., & Hassan, M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.08.17.553675 · Cited by 2
“More specifically, it has been shown that a higher number of electrodes is associated with a significant decrease in localization error (Lantz et al. 2003; Song et al. 2015; Sohrabpour et al. 2015).”
Simulation study on high spatio-temporal resolution acousto-electrophysiological neuroimaging
Schoeters, R., Tarnaud, T., Martens, L., & Tanghe, E. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad169c · Cited by 1
“Also, the localization error increases with depth, while the rate drops with a higher number of electrodes [20].”
Spatial Resolution of Low-Density OPM-MEG: A Comparative Analysis With High-Density EEG
Gao, Z., Cao, F., An, N., Li, W., Wang, W., Yang, J., Wang, D., & Ning, X. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3551466 · Cited by 1
“The spatial localization accuracy of electromagnetic techniques is influenced by various factors, including the sensor configuration [15], accuracy of forward modeling [16], [17], [18], and inverse source imaging method [19].”
Wang, Y., Xiaoni, W., Huang, L., Feng, Y., Pan, Q., Wen, B., Qu, Q., & Xu, J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3529476 · Cited by 1
“Sohrabpour et al. discoveredthatincreasingthenumberofelectrodesenhancedthe performance of source localization in EEG [59].”
The Cost of Simplicity: How Reducing EEG Electrodes Affects Source Localization and BCI Accuracy
Guttmann-Flury, E., Wei, Y., Zhao, S., Zhao, J., & Sawan, M. (2025) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine66377.2025.11340265 · Cited by 1
“While anatomical constraints help restrict possible source configurations, current methods still struggle to distinguish adjacent cortical areas or resolve deep sources, which are critical for enhancing epilepsy treatment outcomes [4], [5].”
EEG Instrumentation and Basics
Ray, A. K., & Issa, N. P. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108754200.012 · Cited by 1
Detección Temprana de Epilepsia Pediátrica: Progresión de los Electrodos en EEG
Miranda, C., Lescher, A., Rojas, A., Molino, J. J., Ibarra, E., & Tristán, S. D. (2023) · European Scientific Journal ESJ · doi:10.19044/esj.2023.v19n6p1 · Cited by 1
A Review of Source Imaging Techniques Based on EEG
Wu, J., & Zhao, C. (2023) · Journal of Artificial Intelligence for Medical Sciences · doi:10.55578/joaims.231215.001 · Cited by 1
“…the spatial resolution of EEG. Sohrabpour et al., in their study on the relationship between the number of EEG channels and brain-source localization in pediatric epilepsy patients, proved that the accuracy of brain-source localization improved with the increase of the number of electrodes [34].”
BackgroundMoBI: Mobile Brain/Body Imaging to Understand Walking and Balance
Tait, P., Timm, E. C., O’Keefe, J. A., Watermeyer, T., Vitório, R. R., Morris, R., & Stuart, S. (2024) · Springer eBooks · doi:10.1007/978-3-031-74123-4_2 · Cited by 1
Improved Back-Projection Cortical Potential Imaging by Multi-resolution Optimization Technique
Haor, D., Joffe, R., Shavit, R., Peremen, Z., Stern, Y., & Geva, A. (2018) · Brain Topography · doi:10.1007/s10548-018-0668-1
Methods Used to Estimate EEG Source-Space Networks: A Comparative Simulation-Based Study
Allouch, S., Duprez, J., Khalil, M. A., Hassan, M., Modolo, J., & Kabbara, A. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871047 · Cited by 1
“[11] recommended using 128 or 256 electrodes, while in [10] the most dramatic decrease in localization error was obtained when going from 32 to 64 electrodes.”
MethodSoler, A. F., Moctezuma, L. A., Giraldo, E., & Molinas, M. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.11.24.469917 · Cited by 1
“Moreover, the results are in line with the widely accepted concept of higher number of channels leading to a higher localization accuracy, which has been previously demonstrated and discussed (Sohrabpour et al. (2015); Song et al. (2015)).”
BackgroundMethodResultInfluentialAllouch, S., Kabbara, A., Duprez, J., Khalil, M. A., Modolo, J., & Hassan, M. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.01.494301 · Cited by 1
“Consistently, (Goran Lantz et al. 2003) and (Sohrabpour et al. 2015) showed that a dramatic decrease in localization error was achieved when increasing the number of electrodes from 32 to 64 electrodes.”
BackgroundResultInfluentialSohrabpour, A., Lu, Y., Worrell, G. A., & He, B. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590652
“However, the number of electrodes used affects the quality of the results as investigated by previous studies [27], [28].”
ResultSelf-citationApplication of Dictionary Learning in Alleviating Computational Burden of EEG Source LocalizationPreprint
Safavi, S. M., Lopour, B. A., & Chou, P. H. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1707.03536
“In addition, although it was shown that increasing the number of electrodes will improve the localization accuracy [11, 12], the computational complexity will grow quadratically with the number of electrodes.”
Background(2012) · SpringerReference · doi:10.1007/springerreference_169250
[Study on precise localization of intraoperative matrix electrode].
Jiang, T., Hu, H., Fu, Q., & Bai, H. (2017) · PubMed Central · doi:10.7507/1001-5515.201608030
EEG Coherence and Intelligence in Elementary School Children
Granados-Ramos, D. E., Sánchez, J. D. L., Figueroa-Rodrguez, S., & Sanabria-Barradas, B. (2019) · Journal of Psychology and Behavioral Science · doi:10.15640/jpbs.v7n2a11
“…and clinicians to better locate areas of interest, either when searching for connectivity between brain areas or when locating epileptic foci (Sohrabpour et al., 2015), for that reason in this research, we used 64 electrodes, because some authors recommend at least this number (Ryynänen et…”
MethodCOALIA: a ground-truth for the evaluation of the EEG source connectivity
Allouch, S., Hassan, M., Yochum, M., Duprez, J., Khalil, M. A., Wendling, F., Modolo, J., & Kabbara, A. (2021) · International Conference on Advances in Biomedical Engineering (ICABME) · doi:10.1109/icabme53305.2021.9604833
Nedergaard, R. B. (2021) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau468595486
Presurgical focus localization in epilepsy
Mouthaan, B. E. (2022) · Utrecht University Repository (Utrecht University) · doi:10.33540/964
MSP Patches Based Optimized EEG Source Localization and Validation in Visual Cortex of Human Brain
Gaho, A. A., Khan, A. M., Musavi, S. H. A., Hasan, M. A., & Shafiq, M. (2022) · Pakistan Journal of Engineering and Technology · doi:10.51846/vol5iss2pp204-210
WEBB, A. G. (2018) · Cambridge University Press eBooks · doi:10.1017/9781316286210.007
Smart instead of high-density EEG
Kokkinos, V., & Schuele, S. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.09.003
Mishra, J., Ramanathan, D., Grennan, G., Nan, J., Jaiswal, S., Purpura, S. R., Manchanda, J. K., Maric, V., & Balasubramani, P. P. (2023) · Research Square · doi:10.21203/rs.3.rs-3304836/v1
Mishra, J., Ramanathan, D., Grennan, G., Nan, J., Jaiswal, S., Purpura, S. R., Manchanda, J. K., Maric, V., & Balasubramani, P. P. (2024) · Research Square · doi:10.21203/rs.3.rs-3813664/v1
Electroencephalography (EEG) Combined with Neuroimaging and Neurostimulation
Vaudano, A. E., Rampp, S., & Lemieux, L. (2025) · Springer eBooks · doi:10.1007/978-3-031-86878-8_19
Mouchnino, L., Cornuault, P.-H., Faucheu, J., Witt, A., Sutter, C., Weiland, B., Blouin, J., Massi, F., Chatelet, E., & Danna, J. (2025) · Journal of Integrative Neuroscience · doi:10.31083/jin43841
Yan, X., Takahashi, T., Kurihara, Y., Ito, M., & Osu, R. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.22.700987
“We utilized a 64-channel EEG system, which offers relatively high accuracy in source estimation (Shen et al., 2023; Sohrabpour et al., 2015).”
Leśniewska, A., Górska, U., Wyczesany, M., Hołda, M., Chojnacki, B., & Binder, M. (2026) · Biological Psychology · doi:10.1016/j.biopsycho.2026.109243 · Cited by 1
Resting-state EEG functional connectivity analysis in benign childhood epilepsy and neonate
Adebimpe, A. (2016) · theses.fr (ABES) · doi:10.70675/24b394a3zd618z4e1ezbf52z364f1629a084
Metadata
- Authors
- Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B.
- Affiliations
- University of Minnesota (US)
- University of Alabama at Birmingham (US)
- Corresponding author
- He, Bin
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 126
- Issue
- 3
- Pages
- 472-480
- ISSN
- 1388-2457 (ISSN-L)
- PMC
- PMC4289666
- OpenAlex
- W2020479538
- Cited by
- 149
- References
- 65
- Citations by year
- 2026: 2 · 2025: 14 · 2024: 9 · 2023: 29 · 2022: 13 · 2021: 16 · 2020: 10 · 2019: 19 · 2018: 8 · 2017: 9 · 2016: 10 · 2015: 7
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- NIH (EB006433, EY023101, HL117664)
- NSF
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- EEG source localization, electrode number, pediatric epilepsy, interictal spikes, electrode configuration, surgical planning, intracranial recordings
- MeSH terms
- Adolescent, Brain, Brain Mapping, Child, Child, Preschool, Computer Simulation, Electrodes, Electroencephalography, Epilepsies, Partial, Female, Humans, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review