The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
The standardized EEG electrode array of the IFCN
Open accessAbstract
Standardized EEG electrode positions are essential for both clinical applications and research. The aim of this guideline is to update and expand the unifying nomenclature and standardized positioning for EEG scalp electrodes. Electrode positions were based on 20% and 10% of standardized measurements from anatomical landmarks on the skull. However, standard recordings do not cover the anterior and basal temporal lobes, which is the most frequent source of epileptogenic activity. Here, we propose a basic array of 25 electrodes including the inferior temporal chain, which should be used for all standard clinical recordings. The nomenclature in the basic array is consistent with the 10-10-system. High-density scalp EEG arrays (64-256 electrodes) allow source imaging with even sub-lobar precision. This supplementary exam should be requested whenever necessary, e.g. search for epileptogenic activity in negative standard EEG or for presurgical evaluation. In the near future, nomenclature for high density electrodes arrays beyond the 10-10 system needs to be defined, to allow comparison and standardized recordings across centers. Contrary to the established belief that smaller heads needs less electrodes, in young children at least as many electrodes as in adults should be applied due to smaller skull thickness and the risk of spatial aliasing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A recent guideline of the International Federation of Clinical Neurophysiology suggests at least 64 channels of EEG should be used for ESI (20).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [20]
Citations
Cites
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Self-citationKlem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,915
&NA; (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199401000-00014 · Cited by 557
Shellhaas, R. A., Chang, T., Tsuchida, T. N., Scher, M. S., Riviello, J. J., Abend, N. S., Tich, S. N. T., Wusthoff, C. J., & Clancy, R. R. (2011) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31823e96d7 · Cited by 500
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
Self-citationEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Self-citationSpatial spectra of scalp EEG and EMG from awake humans
Freeman, W., Holmes, M., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 379
Electric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., & Sato, T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326056 · Cited by 334
Self-citationAcharya, J. N., Hani, A. J., Cheek, J., Thirumala, P. D., & Tsuchida, T. N. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000316 · Cited by 279
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. J. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Consensus Statement on Continuous EEG in Critically Ill Adults and Children, Part II
Herman, S. T., Abend, N. S., Bleck, T. P., Chapman, K. E., Drislane, F. W., Emerson, R. G., Gerard, E. E., Hahn, C. D., Husain, A. M., Kaplan, P. W., et al. (2015) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000165 · Cited by 230
Measurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery
Hoekema, R., Wieneke, G. H., Leijten, F. S. S., Veelen, C. W. M. V., van Rijen, P. C., Huiskamp, G. J. M., Ansems, J., & van Huffelen, A. C. (2003) · Brain Topography · doi:10.1023/a:1025606415858 · Cited by 179
Self-citationIctal eye closure is a reliable indicator for psychogenic nonepileptic seizures
Chung, S. S., Gerber, P., & Kirlin, K. A. (2006) · Neurology · doi:10.1212/01.wnl.0000218160.31537.87 · Cited by 173
Effect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149 · cited 2×
“A recent interictal study using 128-electrodes recordings in pediatric and adult epilepsy patients indicated that at least 64–76 electrodes are desirable to avoid significant source localization errors (Sohrabpour et al., 2015).”
Self-citationElectrical source imaging for presurgical focus localization in epilepsy patients with normal MRI
Brodbeck, V., Spinelli, L., Lascano, A. M., Pollo, C., Schaller, K., Vargas, M. I., Wissmeyer, M., Michel, C. M., & Seeck, M. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02521.x · Cited by 128
Self-citationEffects of eyelid closure, blinks, and eye movements on the electroencephalogram
Iwasaki, M., Kellinghaus, C., Alexopoulos, A. V., Burgess, R. C., Kumar, A. N. S., HAN, Y. H., Lüders, H. O., & Leigh, R. J. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.11.001 · Cited by 127
Lascano, A. M., Perneger, T., Vulliémoz, S., Spinelli, L., Garibotto, V., Korff, C. M., Vargas, M. I., Michel, C. M., & Seeck, M. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.03.025 · Cited by 119
Self-citationCatching the Invisible: Mesial Temporal Source Contribution to Simultaneous EEG and SEEG Recordings
Koessler, L., Cecchin, T., Colnat‐Coulbois, S., Vignal, J., Jonas, J., Vespignani, H., Ramantani, G., & Maillard, L. G. (2014) · Brain Topography · doi:10.1007/s10548-014-0417-z · Cited by 118
Self-citationSpatiotemporal EEG Analysis and Distributed Source Estimation in Presurgical Epilepsy Evaluation
Michel, C. M., de Peralta, R. G., Lantz, G., Andino, S. L. G., Spinelli, L., Blanke, O., Landis, T., & Seeck, M. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00005 · Cited by 118
Self-citationEffects of sutures and fontanels on MEG and EEG source analysis in a realistic infant head model
Lew, S., Sliva, D. D., Choe, M.-S., Grant, P. E., Okada, Y. C., Wolters, C. H., & Hämäläinen, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.017 · Cited by 106
The Role of Functional Neuroimaging in Pre-Surgical Epilepsy Evaluation
Pittau, F., Grouiller, F., Spinelli, L., Seeck, M., Michel, C. M., & Vulliémoz, S. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00031 · Cited by 103
Self-citationDynamic imaging of ictal oscillations using non-invasive high-resolution EEG
Yang, L., Wilke, C., Brinkmann, B., Worrell, G. A., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.043 · Cited by 93
Self-citationAcharya, J. N., Hani, A. J., Thirumala, P. D., & Tsuchida, T. N. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000317 · Cited by 90
Detection of eye blink artifacts from single prefrontal channel electroencephalogram
Chang, W.-D., Cha, H., Kim, K., & Im, C. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.10.011 · Cited by 87
Practical considerations in the positioning of EEG electrodes
Binnie, C. D., Dekker, E., Smit, A., & Linden, G. V. D. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90010-4 · Cited by 81
Spatial localization of EEG electrodes
Koessler, L., Maillard, L. G., Benhadid, A., Vignal, J., Braun, M., & Vespignani, H. (2007) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2007.03.002 · Cited by 81
Self-citationRikir, E., Koessler, L., Gavaret, M., Bartoloméi, F., Colnat‐Coulbois, S., Vignal, J., Vespignani, H., Ramantani, G., & Maillard, L. G. (2014) · Epilepsia · doi:10.1111/epi.12591 · Cited by 77
Self-citationRosenzweig, I., Fogarasi, A., Johnsen, B., Alving, J., Fabricius, M. E., Scherg, M., Neufeld, M. Y., Pressler, R., Kjær, T. W., Boas, W. V. E., et al. (2014) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000019 · Cited by 77
Self-citationThe Influence of Age and Skull Conductivity on Surface and Subdermal Bipolar EEG Leads
Wendel, K. E., Väisänen, J., Seemann, G., Hyttinen, J., & Malmivuo, J. A. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/397272 · Cited by 70
Kuratani, J. D., Pearl, P. L., Sullivan, L. R., Riel-Romero, R. M. S., Cheek, J., Stecker, M. M., San‐Juan, D., Selioutski, O., Sinha, S. R., Drislane, F. W., et al. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000321 · Cited by 68
Patterns of muscle activation during generalized tonic and tonic-clonic epileptic seizures
Conradsen, I., Wolf, P., Sams, T., Sørensen, H. B. D., & Beniczky, S. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03286.x · Cited by 66
Self-citationEEG Mapping and Source Imaging
Michel, C. M., & He, B. (2017) · Oxford University Press eBooks · doi:10.1093/med/9780190228484.003.0045 · Cited by 56
Self-citationAutomated detection and labeling of high-density EEG electrodes from structural MR images
Marino, M., Liu, Q., Brem, S., Wenderoth, N., & Mantini, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056003 · Cited by 51
Neurophysiology of myoclonus and progressive myoclonus epilepsies
AVANZINI, G., Shibasaki, H., Rubboli, G., Canafoglia, L., Panzica, F., Franceschetti, S., & Hallett, M. (2016) · Epileptic Disorders · doi:10.1684/epd.2016.0835 · Cited by 46
Automated differentiation between epileptic and nonepileptic convulsive seizures
Beniczky, S., Conradsen, I., Moldovan, M., Jennum, P., Fabricius, M. E., Benedek, K., Andersen, N., Hjalgrim, H., & Wolf, P. (2014) · Annals of Neurology · doi:10.1002/ana.24338 · Cited by 45
Self-citationAutomatic localization and labeling of EEG sensors (ALLES) in MRI volume
Koessler, L., Benhadid, A., Maillard, L. G., Vignal, J., Felblinger, J., Vespignani, H., & Braun, M. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.039 · Cited by 44
Self-citationQuantitative analysis of surface electromyography: Biomarkers for convulsive seizures
Beniczky, S., Conradsen, I., Pressler, R., & Wolf, P. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.04.017 · Cited by 40
Self-citationA Single Camera Photogrammetry System for Multi-angle Fast Localization of EEG Electrodes
Qian, S., & Yang, S. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0374-6 · Cited by 32
Automatic detection of slow wave sleep using two channel electro-oculography
Virkkala, J., Hasan, J., Värri, A. O., Himanen, S., & Müller, K. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.08.002 · Cited by 23
Flagged first, then by citations
Research works printed but not linked: 1
- Jasper, 1958, The ten-twenty electrode system, Electroencephalogr Clin Neurophysiol, 16, 371
Cited by
Sorted by citations
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 716
“It has therefore been recommended that at least 3 inferior electrodes on each side should be added to the standard 10–20 system in clinical routine (64).”
BackgroundSelf-citationSystematic Review on Resting-State EEG for Alzheimer’s Disease Diagnosis and Progression Assessment
Cassani, R., Estarellas, M., San-Martin, R., Fraga, F. J., & Falk, T. H. (2018) · Disease Markers · doi:10.1155/2018/5174815 · Cited by 415
“Regarding electrode layout, 107 studies used the 10-20 international positioning system (and its variations, 10-10 or 10-5 systems) or the Maudsley system; the remaining five studies [77, 98, 99, 124, 128] acquired EEG signals with 110 or more electrodes using the geodesic system.”
MethodElectrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
“A recent guideline of the International Federation of Clinical Neurophysiology suggests at least 64 channels of EEG should be used for ESI (20).”
Self-citationBabiloni, C., Barry, R. J., Başar, E., Blinowska, K. J., Cichocki, A. S., Drinkenburg, W. H. I. M., Klimesch, W., Knight, R. T., Lopes, F. H. D. S., Nunez, P. L., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.06.234 · Cited by 336
Electrophysiological Brain Connectivity: Theory and Implementation
He, B., Astolfi, L., Valdes-Sosa, P. A., Marinazzo, D., Palva, S., Bénar, C., Michel, C. M., & Koenig, T. W. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913928 · Cited by 242
Self-citation
Metadata
- Authors
- Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S.
- Affiliations
- University Hospital of Geneva (CH)
- Centre National de la Recherche Scientifique (FR)
- Diakonie Kork (DE)
- University Medical Center Utrecht (NL)
- University of Geneva (CH)
- Sigmund Freud Privatuniversität Wien (AT)
- University of Minnesota (US)
- Aarhus University (DK)
- Corresponding author
- Seeck, Margitta
- ORCID
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 128
- Issue
- 10
- Pages
- 2070-2077
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2735688622
- Cited by
- 489
- References
- 41
- Citations by year
- 2026: 47 · 2025: 79 · 2024: 59 · 2023: 70 · 2022: 66 · 2021: 54 · 2020: 46 · 2019: 41 · 2018: 23 · 2017: 3
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Clinical Neurophysiology (acceptedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (publishedVersion)
- HAL (submittedVersion)
- Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- Funders
- Swiss National Science Foundation (140332)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- high-density EEG, epileptogenic activity, preoperative assessment, pediatric EEG, spatial aliasing, skull thickness, anatomical landmarks
- MeSH terms
- Age Factors, Brain, Electrodes, Electroencephalography, Humans, Scalp, Skull
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review