Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Value of Cardiovascular Autonomic Function Tests: 10 Years Experience in Diabetes
Ewing, D. J., Martyn, C. N., Young, R. J., & Clarke, B. F. (1985) · Diabetes Care · doi:10.2337/diacare.8.5.491 · Cited by 1,434
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899 · cited 1×
“Despite this short-coming, the vascular unloading technique has been used extensively and successfully for non-invasive measurement of beat-to-beat blood pressure (see, e.g., [21] [22] [23] [24] [25]).”
MethodPhotoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 529
Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Imholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.214 · Cited by 344
IMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Physiocal, calibrating finger vascular physiology for finapres
Wesseling, K. H., Wit, B. D., van der Hoeven, G. M. A., Goudoever, J. V., & Settels, J. J. (1995) · TU/e Research Portal · Cited by 229
Gratze, G., Fortin, J., Holler, A. E., Grasenick, K., Pfurtscheller, G., Wach, P., Schönegger, J., Kotanko, P., & Skrabal, F. (1998) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(98)00005-5 · Cited by 168
Self-citationYamakoshi, K.-I., Shimazu, H., & Togawa, T. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326616 · Cited by 139 · cited 1×
“, [5–20]), but all of them still use one single control loop which necessitates regular interruptions of the BP tracings for set point recalibration purposes.”
Background
Cited by
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Fortin, J., Habenbacher, W., Heller, A., Hacker, A., Grüllenberger, R., Innerhofer, J., Passath, H., Wagner, C., Haitchi, G., Flotzinger, D., et al. (2006) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2005.06.001 · Cited by 227
Self-citationCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Saugel, B., Dueck, R., & Wagner, J. Y. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.001 · Cited by 162
Metadata
- Authors
- Fortin, J., Marte, W., Grüllenberger, R., Hacker, A., Habenbacher, W., Heller, A., Wagner, C., Wach, P., & Skrabal, F.
- Venue
- Computers in Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2006-09
- Volume
- 36
- Issue
- 9
- Pages
- 941-957
- ISSN
- 0010-4825 (ISSN-L)
- OpenAlex
- W2078920098
- Cited by
- 192
- References
- 28
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.