Next-generation capillary electrophoresis–mass spectrometry approaches in metabolomics
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Capillary electrophoresis-mass spectrometry has shown considerable potential for profiling polar ionogenic compounds in metabolomics. Hyphenation of capillary electrophoresis to mass spectrometry is generally performed via a sheath-liquid interface. However, the electrophoretic effluent is significantly diluted in this configuration thereby limiting the utility of this method for highly sensitive metabolomics studies. Moreover, in this set-up the intrinsically low-flow property of capillary electrophoresis is not effectively utilized in combination with electrospray ionization. Here, advancements that significantly improved the performance of capillary electrophoresis-mass spectrometry are considered, with a special emphasis on the sheathless porous tip interface. Attention is also devoted to various technical aspects that still need to be addressed to make capillary electrophoresis-mass spectrometry a robust approach for probing the polar metabolome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61
Guo, X., Fillmore, T. L., Gao, Y., & Tang, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04912 · Cited by 54
Wang, C., Lee, C. S., Smith, R. D., & Tang, K. (2013) · Analytical Chemistry · doi:10.1021/ac401202c · Cited by 46
Cited by
Review of recent developments in GC–MS approaches to metabolomics-based research
Beale, D. J., Pinu, F. R., Kouremenos, K. A., Poojary, M. M., Narayana, V. K., Boughton, B. A., Kanojia, K., Dayalan, S., Jones, O. A. H., & Dias, D. A. (2018) · Metabolomics · doi:10.1007/s11306-018-1449-2 · Cited by 531
Perez de Souza, L., Alseekh, S., Scossa, F., & Fernie, A. R. (2021) · Nature Methods · doi:10.1038/s41592-021-01116-4 · Cited by 358
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Current and future perspectives of functional metabolomics in disease studies–A review
Yan, M., & Xu, G. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.006 · Cited by 105
Höcker, O., Montealegre, C., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1179-3 · Cited by 55
Metadata
- Authors
- Zhang, W., Hankemeier, T., & Ramautar, R.
- Venue
- Current Opinion in Biotechnology
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 43
- Pages
- 1-7
- ISSN
- 0958-1669 (ISSN-L)
- OpenAlex
- W2505206199
- Cited by
- 128
- References
- 5
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Next-generation capillary electrophoresis–mass spectrometry approaches in metabolomics. https://app.cochat.ai/papers/10.1016/j.copbio.2016.07.002
- The paper
- Zhang, W., Hankemeier, T., & Ramautar, R. (2017). Next-generation capillary electrophoresis–mass spectrometry approaches in metabolomics. Current Opinion in Biotechnology. https://doi.org/10.1016/j.copbio.2016.07.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.