The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Electroencephalography
Open accessAbstract
Electroencephalography (EEG) is the non-invasive measurement of the brain's electric fields. Electrodes placed on the scalp record voltage potentials resulting from current flow in and around neurons. EEG is nearly a century old: this long history has afforded EEG a rich and diverse spectrum of applications. On the one hand, foundations of EEG in clinical diagnostics have dovetailed more recently into brain-triggered neurorehabilitation treatments. On the other hand, EEG has not only been a workhorse for providing brain correlates of constructs in the field of experimental psychology, but has also been used as a true neuroimaging method with more recent extensions in translational as well as computational neuroscience. The versatility and accessibility of the technique, in combination with advances in signal processing, allow for this 'old dog' to still deliver new tricks and innovations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circular analysis in systems neuroscience: the dangers of double dipping
Kriegeskorte, N., Simmons, W. K., Bellgowan, P. S. F., & Baker, C. I. (2009) · Nature Neuroscience · doi:10.1038/nn.2303 · Cited by 2,696
The Oxford Handbook of Event-Related Potential Components
(2011) · doi:10.1093/oxfordhb/9780195374148.001.0001 · Cited by 2,263
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Self-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Topographic ERP Analyses: A Step-by-Step Tutorial Review
Murray, M. M., Brunet, D., & Michel, C. M. (2008) · Brain Topography · doi:10.1007/s10548-008-0054-5 · Cited by 1,127
Self-citationEEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Self-citationWhere Does EEG Come From and What Does It Mean?
Cohen, M. X. (2017) · Trends in Neurosciences · doi:10.1016/j.tins.2017.02.004 · Cited by 722
Brain-actuated functional electrical stimulation elicits lasting arm motor recovery after stroke
Biasiucci, A., Leeb, R., Iturrate, I., Perdikis, S., Al-Khodairy, A., Corbet, T., Schnider, A., Schmidlin, T., Zhang, H., Bassolino, M., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04673-z · Cited by 649
Self-citationHow Local Is the Local Field Potential?
Kajikawa, Y., & Schroeder, C. E. (2011) · Neuron · doi:10.1016/j.neuron.2011.09.029 · Cited by 590
Cited by
Deep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Metadata
- Authors
- Biasiucci, A., Franceschiello, B., & Murray, M. M.
- Venue
- Current Biology
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 29
- Issue
- 3
- Pages
- R80-R85
- ISSN
- 0960-9822 (ISSN-L)
- OpenAlex
- W4234326366
- Cited by
- 450
- References
- 14
- FWCI
- 15.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroencephalography. https://app.cochat.ai/papers/10.1016/j.cub.2018.11.052
- The paper
- Biasiucci, A., Franceschiello, B., & Murray, M. M. (2019). Electroencephalography. Current Biology. https://doi.org/10.1016/j.cub.2018.11.052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.