A modeling study on the revere cycle defrosting of an air source heat pump with the melted frost downwards flowing away and local drainage
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Abstract Reverse cycle defrosting is widely used for air source heat pumps. When a multi-circuit heat exchanger is vertically installed in a heat pump as an outdoor coil, the melted frost could be kept downwards flowing or locally drained during defrosting by using water collecting trays. To analyze the performance differences of melted frost, two defrosting models were developed and previously reported by authors. In this study, the defrosting performance of an air source heat pump was numerically investigated based on the two models, with the melted frost downwards flowing away or local drainage considered. The following physical parameters are predicted and analyzed, including the thermal resistance of refrigerant, temperature of melted frost on tube and fin’s surface, mass of melted frost and energy consumption from refrigerant during defrosting. As calculated, after the melted frost locally drained, the predicted total energy consumption could be decreased from 898.1 kJ to 727.5 kJ, and defrosting efficiency increased from 47.5% to 57.6%. This work is helpful to optimizing the intelligent control strategy of an air source heat pump unit, as well as saving energy for buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384
Self-citationAmer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218
Wenju, H., Yiqiang, J., Minglu, Q., Long, N., Yang, Y., & Shiming, D. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2010.09.024 · Cited by 140
Qu, M., Xia, L., Deng, S., & Jiang, Y. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.08.034 · Cited by 129
Self-citationDetermination method of defrosting start-time based on temperature measurements
Kim, M.-H., & Lee, K.-S. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.02.071 · Cited by 79
Wang, W., Zhang, S., Li, Z., Sun, Y., Deng, S., & Wu, X. (2020) · Energy · doi:10.1016/j.energy.2019.116505 · Cited by 70
Song, M., Deng, S., Pan, D., & Mao, N. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.03.020 · Cited by 66
Self-citationSong, M., Mao, N., Deng, S., Xia, Y., & Chen, Y. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.12.100 · Cited by 55
Self-citationMinglu, Q., Rao, Z., Jianbo, C., Yuanda, C., Xudong, Z., Tongyao, Z., & Zhao, L. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.08.120 · Cited by 47
Qiao, H., Aute, V., & Radermacher, R. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.12.017 · Cited by 46
Cited by
Ma, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54
Xiong, T., Ying, Y., Han, B., Yan, G., & Yu, J. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.09.003 · Cited by 35
Menglong, L., Mengjie, S., Zhenjun, M., Xiaotao, W., & Long, Z. (2021) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2021.103749 · Cited by 25
Li, Z.-L., Zhang, C.-L., Liu, H.-M., & Wang, X.-C. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121828 · Cited by 22
Xiong, T., Chen, Q., Xu, S., Liu, G., Gao, Q., & Yan, G. (2024) · Energy · doi:10.1016/j.energy.2023.129968 · Cited by 21
Niu, J., Liang, Z., Lv, T., Wang, H., & Xu, S. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122472 · Cited by 17
Xiong, T., Hu, L., Liu, G., & Yan, G. (2024) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2024.105069 · Cited by 4
Metadata
- Authors
- Song, M., Xie, G., Pekař, L., Mao, N., & Qu, M.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 226
- Pages
- 110257
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3038935630
- Cited by
- 53
- References
- 12
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.