The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
The benefits of cooperation in a highly renewable European electricity network
Open accessAbstract
To reach ambitious European CO2 emission reduction targets, most scenarios of future European electricity systems rely on large shares of wind and solar photovoltaic power generation. We interpolate between two concepts for balancing the variability of these renewable sources: balancing at continental scales using the transmission grid and balancing locally with storage. This interpolation is done by systematically restricting transmission capacities from the optimum level to zero. We run techno-economic cost optimizations for the capacity investment and dispatch of wind, solar, hydroelectricity, natural gas power generation and transmission, as well as storage options such as pumped-hydro, battery, and hydrogen storage. The simulations assume a 95% CO2 emission reduction compared to 1990, and are run over a full historical year of weather and electricity demand for 30 European countries. In the cost-optimal system with high levels of transmission expansion, energy generation is dominated by wind (65%) and hydro (15%), with average system costs comparable to today's system. Restricting transmission shifts the balance in favour of solar and storage, driving up costs by a third. As the restriction is relaxed, 85% of the cost benefits of the optimal grid expansion can be captured already with only 44% of the transmission volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ERA‐Interim reanalysis: configuration and performance of the data assimilation system
Dee, D. P., Uppala, S. M., Simmons, A. J., Berrisford, P., Poli, P., Kobayashi, S., Andrae, U., Balmaseda, M. A., Balsamo, G., Bauer, P., et al. (2011) · Quarterly Journal of the Royal Meteorological Society · doi:10.1002/qj.828 · Cited by 24,480
Schweppe, F. C., Caramanis, M. C., Tabors, R. D., & Bohn, R. E. (1988) · Springer eBooks · doi:10.1007/978-1-4613-1683-1 · Cited by 2,409
Smart Energy Systems for coherent 100% renewable energy and transport solutions
Mathiesen, B. V., Lund, H., Connolly, D., Wenzel, H., Østergaard, P. A., Möller, B., Nielsen, S., Ridjan, I., Karnøe, P., Sperling, K., et al. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.075 · Cited by 1,265 · cited 1×
“Denmark [17, 18], Germany [19, 20, 21], and Ireland [22]) or considered the whole of Europe but without optimising international cooperation [23].”
BackgroundConnolly, D., Lund, H., & Mathiesen, B. V. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.02.025 · Cited by 715
Lund, H., Andersen, A. N., Østergaard, P. A., Mathiesen, B. V., & Connolly, D. (2012) · Energy · doi:10.1016/j.energy.2012.04.003 · Cited by 653
Budischak, C., Sewell, D., Thomson, H., Mach, L., Veron, D. E., & Kempton, W. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.09.054 · Cited by 536
Seasonal optimal mix of wind and solar power in a future, highly renewable Europe
Heide, D., von Bremen, L., Greiner, M., Hoffmann, C., Speckmann, M., & Bofinger, S. (2010) · Renewable Energy · doi:10.1016/j.renene.2010.03.012 · Cited by 517
Self-citation2012 9th International Conference on the European Energy Market
(2012) · doi:10.1109/eem20221.2012 · Cited by 280
Heide, D., Greiner, M., von Bremen, L., & Hoffmann, C. (2011) · Renewable Energy · doi:10.1016/j.renene.2011.02.009 · Cited by 271
Self-citationSoft-linking of a power systems model to an energy systems model
Deane, J. P., Chiodi, A., Gargiulo, M., & Ó Gallachóir, B. P. (2012) · Energy · doi:10.1016/j.energy.2012.03.052 · Cited by 271
Palzer, A., & Henning, H.-M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.11.032 · Cited by 258
Schaber, K., Steinke, F., & Hamacher, T. (2012) · Energy Policy · doi:10.1016/j.enpol.2011.12.040 · Cited by 257
The Economics of Electricity Markets
(2014) · Wiley eBooks · doi:10.1002/9781118775745 · Cited by 235
Transmission needs across a fully renewable European power system
Rodríguez, R. A., Becker, S., Andresen, G. B., Heide, D., & Greiner, M. (2014) · Renewable Energy · doi:10.1016/j.renene.2013.10.005 · Cited by 230
Self-citationHenning, H.-M., & Palzer, A. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.09.012 · Cited by 183
Current and Prospective Costs of Electricity Generation until 2050
Schröder, A., Kunz, F., Meiss, J., Mendelevitch, R., von Hirschhausen, C., & Deutsches Institut für Wirtschaftsforschung, D. B. (2013) · RePEc: Research Papers in Economics · doi:10.18723/diw_ddc:2013-68 · Cited by 167
Schaber, K., Steinke, F., Mühlich, P., & Hamacher, T. (2012) · Energy Policy · doi:10.1016/j.enpol.2011.12.016 · Cited by 166 · cited 3×
“Other studies only optimise the transmission expansion while fixing the generation fleet [5, 6, 9, 16]; this has the disadvantage that the optimisation cannot weigh up whether it is better to build renewables far from load centres and transport the energy, or build renewables closer to demand.”
BackgroundResultHörsch, J., & Brown, T. (2017) · International Conference on the European Energy Market (EEM) · doi:10.1109/eem.2017.7982024 · Cited by 155
Self-citationBecker, S., Rodríguez, R. A., Andresen, G. B., Schramm, S., & Greiner, M. (2013) · Energy · doi:10.1016/j.energy.2013.10.010 · Cited by 149
Self-citationCost-optimal power system extension under flow-based market coupling
Hagspiel, S., Jägemann, C., Lindenberger, D., Brown, T., Cherevatskiy, S., & Tröster, E. (2014) · Energy · doi:10.1016/j.energy.2014.01.025 · Cited by 131
Self-citationBußar, C., Moos, M., Álvarez-Malebrán, R., Wolf, P., Thien, T., Chen, H., Cai, Z., Leuthold, M., Sauer, D. U., & Moser, A. (2014) · Energy Procedia · doi:10.1016/j.egypro.2014.01.156 · Cited by 113
Andresen, G. B., Søndergaard, A. A., & Greiner, M. (2015) · Energy · doi:10.1016/j.energy.2015.09.071 · Cited by 106
Self-citationSystem strength considerations in a converter dominated power system
Urdal, H., Ierna, R., Zhu, J., Ivanov, C., Dahresobh, A., & Rostom, D. (2014) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2014.0199 · Cited by 102
Scholz, Y. (2012) · elib (German Aerospace Center) · doi:10.18419/opus-2015 · Cited by 98
Cost-optimal design of a simplified, highly renewable pan-European electricity system
Rodríguez, R. A., Becker, S., & Greiner, M. (2015) · Energy · doi:10.1016/j.energy.2015.02.066 · Cited by 85
Self-citationOptimal heterogeneity in a simplified highly renewable European electricity system
Eriksen, E. H., Schwenk-Nebbe, L. J., Tranberg, B., Brown, T., & Greiner, M. (2017) · Energy · doi:10.1016/j.energy.2017.05.170 · Cited by 55
Self-citationOptimising the European transmission system for 77% renewable electricity by 2030
Brown, T., Schierhorn, P., Tröster, E., & Ackermann, T. (2015) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0135 · Cited by 54
Self-citation
Cited by
Brown, T., Schlachtberger, D., Kies, A., Schramm, S., & Greiner, M. (2018) · Energy · doi:10.1016/j.energy.2018.06.222 · Cited by 836
Self-citationAccelerating the energy transition towards photovoltaic and wind in China
Wang, Y., Wang, R., Tanaka, K., Ciais, P., Penuelas, J., Balkanski, Y., Sardans, J., Hauglustaine, D., Liu, W., Xing, X., et al. (2023) · Nature · doi:10.1038/s41586-023-06180-8 · Cited by 754
Status and perspectives on 100% renewable energy systems
Hansen, K., Breyer, C., & Lund, H. (2019) · Energy · doi:10.1016/j.energy.2019.03.092 · Cited by 681
The design space for long-duration energy storage in decarbonized power systems
Sepulveda, N. A., Jenkins, J. D., Edington, A., Mallapragada, D. S., & Lester, R. K. (2021) · Nature Energy · doi:10.1038/s41560-021-00796-8 · Cited by 689
Child, M., Kemfert, C., Bogdanov, D., & Breyer, C. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.02.077 · Cited by 605
Metadata
- Authors
- Schlachtberger, D. P., Brown, T., Schramm, S., & Greiner, M.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2017-09
- Volume
- 134
- Pages
- 469-481
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2609399436
- Cited by
- 308
- References
- 27
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.