Development and validation of a dynamic modeling framework for air-source heat pumps under cycling of frosting and reverse-cycle defrosting
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, C.-C., Chi, K.-Y., & Chang, C.-J. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00333-6 · Cited by 546
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384
A one-dimensional model for frost formation on a cold flat surface
Lee, K.-S., Kim, W.-S., & Lee, T.-H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(97)00074-4 · Cited by 296
A study of frost growth and densification on flat surfaces
Hermes, C. J. L., Piucco, R. O., Barbosa, J. R., & Melo, C. (2009) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2008.10.006 · Cited by 257
New model for frost growth rate
Na, B., & Webb, R. L. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2003.09.001 · Cited by 212
Prediction of the frost formation on a cold flat surface
Lee, K.-S., Jhee, S., & Yang, D.-K. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00195-9 · Cited by 190
Frost formation with varying environmental parameters
Jones, B. W., & Parker, J. D. (1975) · Journal of Heat Transfer · doi:10.1115/1.3450350 · Cited by 171
Mass transfer on and within a frost layer
Na, B., & Webb, R. L. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2003.08.023 · Cited by 129
State-of-the-art review of frost deposition on flat surfaces
Léoni, A., Mondot, M., Durier, F., Revellin, R., & Haberschill, P. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.04.004 · Cited by 103
Hot gas defrost model development and validation
Hoffenbecker, N., Klein, S. A., & Reindl, D. T. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.08.016 · Cited by 84
Chung, Y., Yoo, J. W., Kim, G. T., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.10.085 · Cited by 81
Brèque, F., & Nemer, M. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.06.010 · Cited by 70
First-principles modeling of frost accumulation on fan-supplied tube-fin evaporators
da Silva, D. L., Hermes, C. J. L., & Melo, C. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.04.029 · Cited by 70
Modeling non-uniform frost growth on a fin-and-tube heat exchanger
Padhmanabhan, S. K., Fisher, D. E., Cremaschi, L., & Moallem, E. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.06.005 · Cited by 66
Parametric analysis of the defrosting process of a reversible heat pump system for electric vehicles
Steiner, A., & Rieberer, R. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.07.044 · Cited by 58
Modelling and experimental validation of the hot-gas defrost process of an air-cooled evaporator
Dopazo, J. A., Fernandez-Seara, J., Uhía, F. J., & Diz, R. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.12.027 · Cited by 55
Qiao, H., Aute, V., & Radermacher, R. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.12.017 · Cited by 46
Hwang, J., & Cho, K. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.04.026 · Cited by 44
Qiao, H., Aute, V., & Radermacher, R. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.08.020 · Cited by 29
Frosting in a heat pump evaporator part B: Numerical analysis
Popovac, M., Emhofer, J., & Reichl, C. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117488 · Cited by 26
Modeling of a fan-supplied flat-tube heat exchanger exposed to non-uniform frost growth
Breque, F., & Nemer, M. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.12.012 · Cited by 21
Research works printed but not linked: 23
- Maldonado, 2018, Control strategies for defrost and evaporator fans operation in walk-in freezers, Int J Refrig, 91, 101, 10.1016/j.ijrefrig.2018.05.025 · DOI
- Qu, 2012, A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump–Part II: Modeling analysis, Appl Energy, 91, 274, 10.1016/j.apenergy.2011.08.036 · DOI
- Song, 2020, A modeling study on the revere cycle defrosting of an air source heat pump with the melted frost downwards flowing away and local drainage, Energy Build, 226, 10.1016/j.enbuild.2020.110257 · DOI · Paper page
- Han, 2022, Parametric study of a room air conditioner during defrosting cycle based on a modified defrosting model, Energy, 238, 10.1016/j.energy.2021.121658 · DOI
- Laughman, 2015, A comparison of transient heat pump cycle models using alternative flow descriptions, Sci Technol Built Environ, 21, 666, 10.1080/23744731.2015.1040342 · DOI
- Didi, 2002, Prediction of two-phase pressure gradients of refrigerants in horizontal tubes, Int J Refrig, 25, 935, 10.1016/S0140-7007(01)00099-8 · doi:10.1016/s0140-7007(01)00099-8
- Kim, 2018, Computationally efficient modeling strategy for evaporator performance under frost conditions, Int J Refrig, 96, 88, 10.1016/j.ijrefrig.2018.09.004 · DOI
- Leoni, 2017, Frost formation and development on flat plate: Experimental investigation and comparison to predictive methods, Exp Therm Fluid Sci, 88, 220, 10.1016/j.expthermflusci.2017.06.005 · DOI
- El Cheikh, 2014, A mathematical model for frost growth and densification on flat surfaces, Int J Heat Mass Transfer, 77, 604, 10.1016/j.ijheatmasstransfer.2014.05.054 · DOI
- Takagi, 1985, Fuzzy identification of systems and its applications to modeling and control, IEEE Trans Syst Man Cybern, 116, 10.1109/TSMC.1985.6313399 · DOI · Paper page
- Kim, 2021, Fuzzy modeling approach for transient vapor compression and expansion cycle simulation, Int J Refrig, 121, 114, 10.1016/j.ijrefrig.2020.10.025 · doi:10.1016/j.ijrefrig.2020.10.025
- Li, 2013, Simplified modeling analysis of mass flow characteristics in electronic expansion valve, Appl Therm Eng, 53, 8, 10.1016/j.applthermaleng.2012.12.035 · doi:10.1016/j.applthermaleng.2012.12.035
- Liu, 2022, A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis, Int J Refrig, 133, 191, 10.1016/j.ijrefrig.2021.10.013 · doi:10.1016/j.ijrefrig.2021.10.013
- Qiao, 2015, Transient modeling of a flash tank vapor injection heat pump system–Part I: Model development, Int J Refrig, 49, 169, 10.1016/j.ijrefrig.2014.06.019 · DOI
- Damasceno, 1991, Effects of reversing valves on heat pump performance, Int J Refrig, 14, 93, 10.1016/0140-7007(91)90081-Q · doi:10.1016/0140-7007(91)90081-q
- Churchill, 1975, Correlating equations for laminar and turbulent free convection from a vertical plate, Int J Heat Mass Transfer, 18, 1323, 10.1016/0017-9310(75)90243-4 · DOI · Paper page
- Gnielinski, 1976, New equations for heat and mass transfer in turbulent pipe and channel flow, Int Chem Eng, 16, 359
- Gungor, 1987, Simplified general correlation for saturrated flow boiling and comparison of correlation with data, Chem Eng Res Dev, 65, 148
- Shah, 1979, A general correlation for heat transfer during film condensation inside pipes, Int J Heat Mass Transfer, 22, 547, 10.1016/0017-9310(79)90058-9 · DOI
- Grönnerud, 1972, Investigation of liquid hold-up, flow-resistance and heat transfer in circulation type evaporators, part IV: two-phase flow resistance in boiling refrigerants, Bull de L’Inst Du Froid, Annexe, 1
- Lockhart, 1949, Proposed correlation of data for isothermal two-phase, two-component flow in pipes, Chem Eng Prog, 45, 39
- Song, 2017, Energy transfer procession in an air source heat pump unit during defrosting, Appl Energy, 204, 679, 10.1016/j.apenergy.2017.07.063 · DOI
- Pangborn, 2015, A comparison between finite volume and switched moving boundary approaches for dynamic vapor compression system modeling, Int J Refrig, 53, 101, 10.1016/j.ijrefrig.2015.01.009 · doi:10.1016/j.ijrefrig.2015.01.009
Cited by
Ma, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29
Xiong, T., Chen, Q., Xu, S., Liu, G., Gao, Q., & Yan, G. (2024) · Energy · doi:10.1016/j.energy.2023.129968 · Cited by 21
Frost/Defrost Models for Air-Source Heat Pumps with Retained Water Refreezing Considered
Ma, J., & Thorade, M. (2024) · arXiv · doi:10.48550/arxiv.2412.00017 · Cited by 1
“…existing frost/defrost models for heat pump systems focused on switches between frost formation and melting behaviors, omitting the impacts of retained water refreezing and melting on transients of cyclic frosting and defrosting (Qiao, Aute, and Radermacher 2018; Ma et al. 2023; Alam et al. 2024).”
Self-citation
Metadata
- Authors
- Ma, J., Kim, D., Braun, J. E., & Horton, W. T.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2023-06
- Volume
- 272
- Pages
- 127030
- ISSN
- 0360-5442
- Cited by
- 41
- References
- 21
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Funders
- Purdue University (CHPB-49-2021)
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (IRG 015-1920)
- Ray W. Herrick Laboratories, Purdue University
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.